Preface
About this manual
This manual provides information regarding the quick installation and hardware features
of the EP-2126-SA3 RAID subsystem. This document also describes how to use the
storage management software. Information contained in the manual has been reviewed
for accuracy, but not for product warranty because of the various
environment/OS/settings. Information and specifications will be changed without further
notice.
This manual uses section numbering for every topics being discussed for easy and
convenient way of finding information in accordance with the user’s needs. The following
icons are being used for some details and information to be considered in going through
with this manual:
Copyright
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise, without the prior written consent.
Trademarks
All products and trade names used in this document are trademarks or registered
trademarks of their respective holders.
Changes
The material in this document is for information only and is subject to change without
notice.
IMPORTANT!
These are the important information that the user must remember.
WARNING!
These are the warnings that the user must follow to avoid
unnecessary errors and bodily injury during hardware and software
operation of the subsystem.
CAUTION:
These are the cautions that user must be aware to prevent damage
to the equipment and its components.
NOTES:
These are notes that contain useful information and tips that the
user must give attention to in going through with the subsystem
operation.

3
TABLE OF CONTENTS
Preface...................................................................................................................... 2
Before You Begin...................................................................................................... 5
Safety Guidelines ........................................................................................................5
Controller Configuration...............................................................................................5
Packaging, Shipment and Delivery ................................................................................5
Unpacking the Subsystem ........................................................................................6
1 Product Introduction........................................................................................... 7
1.1 Identifying Parts of the EP-2126-SA3.....................................................................8
1.1.1 Front View....................................................................................................8
1.1.2 Rear View ....................................................................................................8
1.1.3 Top View......................................................................................................8
1.2 Enclosure Chassis ................................................................................................9
1.3 Technical Specifications ...................................................................................9
1.3.1 RAID Features...............................................................................................9
1.3.2 Enclosure.................................................................................................... 10
1.3.3 Environmental............................................................................................. 10
2 Physical Components......................................................................................... 11
2.1 Controller Module .............................................................................................. 11
2.1.1 Controller Module Panel............................................................................... 11
2.1.2 Controller Module Installation....................................................................... 12
2.1.3 Controller Board Replacement...................................................................... 13
2.2 Power Supply / Fan Module ................................................................................ 14
2.2.1 PSFM Panel ................................................................................................ 14
2.2.2 Power Supply Module LED ........................................................................... 15
2.2.3 Power Supply Installation ............................................................................ 15
2.2.4 Fan Replacement ........................................................................................ 17
2.3 Drive Carrier Module.......................................................................................... 18
2.3.1 Disk Drive Status Indicators ......................................................................... 18
2.3.2 Lock Indicator............................................................................................. 19
2.3.3 Disk Drive Installation ................................................................................. 19
2.4 LCD Display Panel.............................................................................................. 21
2.4.1 LCD Display Panel LEDs............................................................................... 21
2.4.2 LCD Front Panel Function Keys ..................................................................... 22
2.5 Rackmount Slide Rail Installation ........................................................................ 23
3 Getting Started with the Subsystem................................................................. 27
3.1 Connecting the RAID Subsystem to the Host.......................................................... 27
4 Introduction ...................................................................................................... 28
4.1 RAID Concepts.................................................................................................. 28
4.2 SCSI Concepts .................................................................................................. 32
4.2.1 Multiple SCSI Format Support ...................................................................... 32
4.2.2 Host SCSI ID Selection ................................................................................ 33
4.2.3 Terminators................................................................................................ 33
4.3 Disk Drive Organization...................................................................................... 33
4.3.1 Physical Drive Groups.................................................................................. 33
4.3.2 Logical Unit Number (LUNs)......................................................................... 33
4.3.3 Hot-Swap Drive Replacement....................................................................... 34
4.3.4 Disk Failure Detection.................................................................................. 34
5 Configuration Utility Options............................................................................. 35
5.1 Configuring through a Terminal .......................................................................... 35
5.2 Configuring the Subsystem Using the LCD Panel .................................................. 38
6 Accessing the proRAID Manager GUI................................................................ 40
6.1 Installation........................................................................................................ 40
6.1.1 Installing on Windows System....................................................................... 40
6.1.2 Installing on Linux ...................................................................................... 43
6.2 Starting ProRAID Manager.................................................................................. 44

4
6.3 Configuration Procedures ................................................................................... 46
6.3.1 Change Password ....................................................................................... 46
6.3.2 Mount RAID Subsystem............................................................................... 46
6.3.3 Detach RAID Subsystem.............................................................................. 47
6.3.4 View proRAIDMgr Log ................................................................................. 47
6.3.5 Event Manager ........................................................................................... 48
7 RAID Management ............................................................................................ 50
7.1 About RAID....................................................................................................... 50
7.1.1 RAID Considerations ................................................................................... 50
7.2 Array Status...................................................................................................... 51
7.2.1 Array Properties.......................................................................................... 52
7.3 Creating a RAID ................................................................................................ 54
7.3.1 Configuring Array Options............................................................................ 54
7.3.2 Rebuilding an Array..................................................................................... 58
7.4 Parity Checking a RAID ...................................................................................... 59
7.5 Modifying RAID Settings..................................................................................... 59
7.5.1 Erase the RAID ........................................................................................... 60
7.5.2 Change Settings.......................................................................................... 60
7.5.3 Delete Volume ............................................................................................ 61
7.6 Selecting/Changing a Sparing disk ...................................................................... 61
8 Channel Management........................................................................................ 62
8.1 Multiple SCSI Format Support............................................................................. 62
8.2 Host SCSI ID Selection....................................................................................... 62
8.3 Configuring Channel Options .............................................................................. 62
9 System Monitoring ............................................................................................ 64
9.1 System Information ........................................................................................... 64
9.2 Slot List (Disk View)........................................................................................... 64
9.3 LUN Mapping Information .................................................................................. 65
9.4 Controller Log ................................................................................................... 65
9.5 Hardware Monitor.............................................................................................. 66
10 Administration Menu....................................................................................... 67
10.1 System Setting ................................................................................................ 67
10.2 NTP setting ..................................................................................................... 69
10.3 Mail Notification............................................................................................... 70
10.4 SNMP Settings................................................................................................. 71
10.5 Restart ........................................................................................................... 71
10.6 Set Faulty ....................................................................................................... 71
10.7 Updating Firmware .......................................................................................... 72
10.7.1 Upgrading Firmware through VT-100 Terminal Emulation ............................. 72
10.7.2 Upgrading Firmware through proRAID Management..................................... 74
APPENDIX............................................................................................................... 75
Menu Diagram .......................................................................................................... 75

5
Before You Begin
Before going through with this manual, you should read and focus to the following safety
guidelines. Notes about the subsystem’s controller configuration and the product
packaging and delivery are also included.
Safety Guidelines
To provide reasonable protection against any harm on the part of the user and to obtain
maximum performance, user is advised to be aware of the following safety guidelines
particularly in handling hardware components:
Upon receiving of the product:
Place the product in its proper location.
To avoid unnecessary dropping out, make sure that somebody is around for
immediate assistance.
It should be handled with care to avoid dropping that may cause damage to the
product. Always use the correct lifting procedures.
Upon installing of the product:
Ambient temperature is very important for the installation site. It must not exceed
30◦C. Due to seasonal climate changes; regulate the installation site temperature
making it not to exceed the allowed ambient temperature.
Before plugging-in any power cords, cables and connectors, make sure that the
power switches are turned off. Disconnect first any power connection if the power
supply module is being removed from the enclosure.
Outlets must be accessible to the equipment.
All external connections should be made using shielded cables and as much as
possible should not be performed by bare hand. Using anti-static hand gloves is
recommended.
In installing each component, secure all the mounting screws and locks. Make sure
that all screws are fully tightened. Follow correctly all the listed procedures in this
manual for reliable performance.
Controller Configuration
This RAID subsystem supports single controller configuration.
Packaging, Shipment and Delivery
Before removing the subsystem from the shipping carton, you should visually inspect
the physical condition of the shipping carton.
Unpack the subsystem and verify that the contents of the shipping carton are all
there and in good condition.
Exterior damage to the shipping carton may indicate that the contents of the carton
are damaged.
If any damage is found, do not remove the components; contact the dealer where
you purchased the subsystem for further instructions.

6
Unpacking the Subsystem
The package contains the following items:
• RAID subsystem unit
• Two power cords
• One external serial cable
• One external UPS cable
• One RJ-45 Ethernet cable
• Two external SCSI cables
• Two Active Terminators
• Installation Reference Guide
• Spare screws, etc.
If any of these items are missing or damaged, please contact your dealer or sales
representative for assistance.

7
1 Product Introduction
The EP-2126-SA3 RAID Subsystem
Features:
Intel 80331 64 bit I/O processor
Supports RAID levels 0, 1, 0+1, 3, 5, 6, 30, 50, NRAID and JBOD
Dual SCSI Ultra320 host channels support clustering technology
Instant availability and background initialization
Supports hot spare and automatic hot rebuild
Local audible event notification alarm
Real time drive activity and status indicators
Java based browser type GUI management utility
Supports password protection and UPS connection
Built-in Ethernet port interface for remote event notification
Transparent data protection for all popular operating systems
Supports multiple array enclosures per host connection

8
1.1 Identifying Parts of the EP-2126-SA3
The illustrations below identify the various parts of the subsystem. Each part will be
discussed in details in the following sections of this manual.
1.1.1 Front View
The front section consists of the Drive Carriers and the Smart LCD Panel.
1.1.2 Rear View
The rear view consists of the two Power Supply / Fan Modules and the Controller.
1.1.3 Top View
The illustration below shows the top view of the subsystem (without top cover)
indicating the controller and the two power supply fan module.

9
1.2 Enclosure Chassis
The EP-2126-SA3 is a redundant system with hot swappable disks, cooling fans and
power supplies. The chassis assembly contains 12 drive bays at the front. These drive
carriers are arranged in 3 rows of 4 drives. Each drive carrier is lockable and has a lock
indicator.
At the rear, the chassis assembly contains two power supply /fan modules and one
controller module. The power supply and cooling system is contained in one module for
efficient cooling.
NOTE: The modules of the enclosure are interchangeable with
other Epica products.
1.3 Technical Specifications
RAID Controller U320 SCSI-to-SATA II
Host Bus Interface Ultra 320 SCSI
Drive Bus Interface SATA II
Data Transfer Rate Up to 320MB/Sec
Cache Memory 256MB ~ 2GB ECC DDR SDRAM
RAID Processor Intel 80331 64 bit RISC
Remote Management R-Link Port
Monitor Port RS232
1.3.1 RAID Features
RAID Level 0, 1, 0+1, 3, 5, 6, 30, 50, NRAID and
JBOD
RAID Roaming Yes
Host Independent Yes
Continuous Rebuild Yes
Online Consistency Check Yes
Failed Drive Auto Rebuild Yes
Password Protection Yes
Bad Block Auto-remapping Yes
Hard Contact Relay Connection Yes
SMTP Manager and SNMP Agent Yes

10
1.3.2 Enclosure
Form Factor 2U 19-inch Rackmount Chassis
Failed Drive Indicators Yes
Backplane Board SATA II
Audible Alarm Yes
Hot-swap Drive Trays Twelve (12) 1-inch trays
Hot-swappable Power Supplies Two (2) 300W Power Supplies with PFC
Cooling Fans 2
UPS Connection Yes
Environment Monitor Monitor Temperature, Fan, Power Supply
and Voltage
Power Requirements AC 90V~264V Full Range
6A ~ 3A, 47Hz ~ 63Hz
1.3.3 Environmental
Relative Humidity 10% ~ 85% Non-condensing
Operating Temperature 10◦C ~ 40◦C (50◦F ~ 104◦F)
Weight 14 kg/30.8Lbs (without drives)
Physical Dimensions 482(W) x 460(D) x 88(H) mm
Table of contents
Other Proware Storage manuals

Proware
Proware EP-2126-SS User manual

Proware
Proware EP-3163J/JD-SCSC User manual

Proware
Proware SB-1413-UA Manual

Proware
Proware EP-3164D-GAS3 User manual

Proware
Proware Fibre to SAS/SATA II RAID Subsystem User manual

Proware
Proware EN-2126JS6-SQX User manual

Proware
Proware DP-503-F4A3 User manual

Proware
Proware EP-3163S-F8S6 User manual

Proware
Proware EN-1400A6B-CM User manual

Proware
Proware SB-3164E-G1S3 User manual