PRIMERGY TX200 S3 Owner's manual

PRIMERGY
PRIMERGY TX200 S3
Server
Service Supplement
Susanne Däschlein
Fujitsu Siemens Computers GmbH München
81730 München
Tel.: (089) 61001155
Fax: (++49) 700 / 372 00000
TX200 S3
Sprachen: En
Edition July 2006

Comments…Suggestions…Corrections…
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Fax forms for sending us your comments are included in
the back of the manual.
There you will also find the addresses of the relevant
User Documentation Department.
Certified documentation
according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademar s
Copyright © 2006 Fujitsu Siemens Computers GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.

TX200 S3 Service Supplement
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 5
1.2 Notational conventions . . . . . . . . . . . . . . . . . . . . . . 8
2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4 Replacement routines . . . . . . . . . . . . . . . . . . . . . 17
4.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 17
4.1.1.2 Removing the front cover . . . . . . . . . . . . . . . . . . . . 17
4.1.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.2.2 Removing the rack front cover . . . . . . . . . . . . . . . . . . 18
4.2 Replacing the operating panel . . . . . . . . . . . . . . . . . 19
4.3 Replacing the floppy disk drive (multibay) . . . . . . . . . . . . 20
4.4 Replacing the standard fans . . . . . . . . . . . . . . . . . . . 22
4.5 Replacing the processor fan holder . . . . . . . . . . . . . . . 23
4.6 Replacing the standard PS . . . . . . . . . . . . . . . . . . . 23
4.7 Replacing the Power backplane . . . . . . . . . . . . . . . . . 27
4.8 Replacing the SAS backplane/SCSI backplane . . . . . . . . . 29
4.9 Replacing the adapter board for system fans . . . . . . . . . . 34
4.10 Replacing the intrusion switches . . . . . . . . . . . . . . . . 36
4.11 Replacing the IDTEMP combo . . . . . . . . . . . . . . . . . 41
4.12 Replacing the system board . . . . . . . . . . . . . . . . . . . 42
5 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
5.1 Board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
5.1.1 Operating panel board . . . . . . . . . . . . . . . . . . . . . 47
5.1.2 SAS backplane 1-channel . . . . . . . . . . . . . . . . . . . . 48
5.1.3 SCSI backplane 1-channel . . . . . . . . . . . . . . . . . . . 49
5.1.4 Power backplane . . . . . . . . . . . . . . . . . . . . . . . . 50
5.1.5 Processor fan backplane . . . . . . . . . . . . . . . . . . . . 51
5.1.6 Adapter board for system fans . . . . . . . . . . . . . . . . . 52
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53


TX200 S3 Service Supplement 5
1Introduction
The PRIMERGY TX200 S3 Server is an Intel-based server for medium-sized
and large networks. The server is suitable for use as a file server as well as an
application, information, or Internet server. It is available as a floorstand or rack
model. The floorstand model can be converted to a rack model using an optional
conversion kit.
1.1 Overview of the documentation
Concept and target groups
This Service Supplement completes the information given in the Operating
Manual, the Options Guide and the Technical Manual of the system board.
The activities described in this manual may only be performed by service
personnel.
Service DVD
Service partners of Fujitsu Siemens can order a Service DVD PRIMERGY. On
the DVD the following manuals are available in pdf format:
– The “Safety notes and other important information” manual
– The Operating Manual for PRIMERGY TX200 S3
– The Technical Manual for the system board D2109 and the SAS controller
D2107
– The Options Guide for PRIMERGY TX200 S3
– The Service Supplement PRIMERGY TX200 S3
– The “BIOS Setup” manual

6 Service Supplement TX200 S3
Overview of the documentation Introduction
Information/procedure Manual
Detailed safety notes Safety
Features and technical data of the server Operating Manual
Installation and operation, among other things:
– External ports
– Operation
– Configuration of the server
– Installation of the rack mounting kit
Troubleshooting
Installation/removal of all hot-plug components:
– hot-plug power supply units
– hot-plug hard disk drives
– hot-plug system fans / processor fans
Information about the system board:
– Features of the system board
– Board layout
– Jumper settings
–LEDdisplays
– SAS controller D2107
– Replacing the battery
Technical Manual
Table 1: Overview of the documentation TX200 S3

TX200 S3 Service Supplement 7
Introduction Overview of the documentation
Extensions and upgrades:
IFor some components only the installation
routine is described in the Options Guide.
Removing this components proceed in
reverse order.
– Extending/replacing the main memory
– Installing a second processor / replacing the
processor / replacing the heat sink
– Installing accessible drives, like slim line
CD/DVD-ROM drive etc.
– Installing the SCSI hard disk extension box
– Installing controller in the PCI slots
– Inserting the RAID key
– Installing a parallel interface for printers
– Upgrading to redundant system fans
– Conversion standard PS to hot-plug PS
– Converting from the floorstand model to the
rack model
Options Guide
Cabling
Replacement routines:
– Replacing the operating panel
– Replacing the floppy disk drive (multibay)
– Replacing the standard fans
– Replacing the processor fan holder
– Replacing the standard PS
– Replacing the Power backplane
– Replacing the SAS backplane/SCSI backplane
– Replacing the adapter board for system fans
– Replacing the intrusion switches
– Replacing the IDTEMP Combo
– Replacing the system board
Service Supplement
Board layout
BIOS setup BIOS Setup
Information/procedure Manual
Table 1: Overview of the documentation TX200 S3

8 Service Supplement TX200 S3
Notational conventions Introduction
1.2 Notational conventions
The following notational conventions are used in this manual:
Text in italics indicates commands, menu items or software programs.
„Quotation marks“ indicate names of chapters and terms that are being
emphasized.
Êdescribes activities that must be performed in the order
shown.
VCAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
Iindicates additional information, notes and tips.
Table 2: Notational conventions

TX200 S3 Service Supplement 9
2Procedure
VCAUTION!
The actions described in these instructions should only be performed by
service personnel.
ÊFirst of all please familiarize yourself with the safety instructions in the
section chapter “Safety notes” on page 11 et seq. .
ÊEnsure that all required manuals (see Service DVD) are available, printing
out the PDF files if necessary. You will definitely need the Operating Manual
for the server, the Options Guide for the server and the Technical Manual for
the system board.
ÊShut down the server correctly, switch it off, pull out the power plug, and
open the server as described in the chapter “Replacement routines” on
page 17 et seq. .
ÊReplace the defective component as described in the relevant chapter.
IProcedures which are identical for the floorstand and rack models are
only described for the floorstand model.
ÊClose the server.1
ÊConnect the cables. 1
ÊConnect the server to the power outlet.1
ÊStart the operating system.1
ÊIf necessary, configure the server as required.1
1This procedures are described in the Operating Manual.

Other manuals for TX200 S3
2
Table of contents
Other PRIMERGY Server manuals

PRIMERGY
PRIMERGY RX100 S4 User manual

PRIMERGY
PRIMERGY TX200 S3 User manual

PRIMERGY
PRIMERGY TX300 S3 User manual

PRIMERGY
PRIMERGY TX150 S5 User manual

PRIMERGY
PRIMERGY RX200 User manual

PRIMERGY
PRIMERGY BX600 S2 Installation instructions

PRIMERGY
PRIMERGY TX200 S3 User manual

PRIMERGY
PRIMERGY BX620 S2 User manual

PRIMERGY
PRIMERGY TX150 S4 User manual

PRIMERGY
PRIMERGY BX600 S3 Installation instructions