This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in
accordance with this hardware guide may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own
expense.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IDS Switch are trademarks of Perle Systems Limited.
©2016 - 2019 Perle Systems Limited.

Table of Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Switch Models Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Terminal Block Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
DIP Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Terminal Block-Power Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Grounding the IDS switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Connecting Power to the IDS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Wiring the Relay Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Wiring Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Connecting the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Connecting Data Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Resetting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Configuring the IDS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Appendix A - Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Appendix B - Sample Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Appendix C - Mechanical Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Appendix D - DIN Rail and Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Appendix E - IDS Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Appendix F - Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

2
IDS-409C Hardware Installation Guide
Preface
Audience
This guide is for the network or computer technician responsible for installing Perle IDS
series switches. Familiarity with the concepts and terminology of Ethernet and local area
networks is required.
Purpose
This document describes the hardware and physical characteristics of the Perle IDS
switch. It covers hardware features as well as installation and operation of the switch. This
document does not cover how to configure your Perle IDS switch. Information to config-
ure your Perle IDS switch can be found in the User’s Guide
Package Contents
• IDS switch with attached DIN rail mounting bracket
• Quick Start Guide
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used to
help you identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that
could result in equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on
any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Only qualified personnel should connect
power to this unit.

Overview 3
IDS-409C Hardware Installation Guide
Overview
This chapter discusses the following topics:
• LED Indicators
• Switch Model View
• Ports
• Port Status Indicators
The table below gives a brief overview of the models covered in this guide. For more
details and for the most up-to-date list of models, please refer to the product pages at
www.perle.com.
Standard Models 10/100/1000Base-T
Ports
Combo
Ports Temp
IDS-409C 5 4 Standard
IDS-409C-XT 5 4 Industrial

Overview 4
IDS-409C Hardware Installation Guide
Switch Models Views
IDS-409C
IDS-409C-XT
1 – Terminal Block for Power 1, 2 7 – 10/100/1000Base-T Ports
2 – Status LEDs 8 – SD Card Slot
3 – Console Port – serial 9 – Terminal Block – Relay, I/O
4 – Console Port – USB 10 - Reset / FS (Fast Setup)
5 – DIP switches 11 -Wall Mount Bracket Screw Holes
6 – Ethernet/Fiber Combo Ports 12 - DIN Rail Clip

Overview 5
IDS-409C Hardware Installation Guide
LED Indicators
P (Power Inputs)
Sys (System Status)
Alr (Alarm)
BC (Backup Coupling)
State Description
Green P1 and P2 Power inputs within specifications
Yellow P1 or P2 Providing power within specifications
Red Neither P1 or P2 providing power within specifications
State Description
Green - blinking (after power on) System booting
Green - solid System ready/operating normally
Green - blinking slowly Fast Setup Mode activated/port available
Green - blinking fast Fast Setup Mode activated/no port avail-
able
Red Hardware fault or firmware load error
State Description
Off No alarms configured
Green - solid Alarms configured, but no alarms detected
Red - solid Alarm condition detected
Red - blinking Alarm condition detected and Alarm Relay activated
State Description
Off Backup Coupling not enabled
Green - solid Backup Coupling Link enabled

Overview 6
IDS-409C Hardware Installation Guide
RM (Ring Master)
State Description
Off Ring Master not activated
Green - solid Ring Master Active, redundant port blocked. Coupling
Link enabled
Green - flashing Ring Master unable to establish a ring due to missing
link on one of the Ring ports
Yellow - solid Ring Master Active, redundant port unblocked - indi-
cates a break in the Ring

Overview 7
IDS-409C Hardware Installation Guide
Ports
10/100/1000Base-T Ports
These ports provide the standard gigabit Ethernet interface. They provide speeds of 10/
100 or 1000 Mb/s through twisted pair (UTP) cables of up to 100 meters (328ft) in length.
Combo ports (Dual purpose)
Through configuration or through auto-detection Combo ports provide two physical port
options for one logical switch port. A link may be established on either the SFP module
inserted in the slot or on the 10/100/1000Base-T port associated with it. If both ports are
occupied (Ethernet and SFP module), the SFP module will take priority
100/1000 Mb/s SFP Slots
The SFP slots can accommodate industry standard SFP’s from Perle or other suppliers.
These SFP’s can be 100 or 1000 Mb/s or can be SGMII models including 1000Base-T
Copper SFP’s.
RJ-45 Console Port
This is a console management port providing access to the switch management function
using the industry standard CLI command set. This port has an RJ-45 connector. See RJ-
45-Console Port Pinouts.
USB Console Port
The MicroUSB port is an alternative connection to the switch’s console. This provides
access to the switch management function using the industry standard CLI command set.
When connected the port presents a serial interface that can be used from a PC Terminal
emulation program (such as PuTTY).
Power Connector
The power input connector has provisions for dual inputs. Two independent power
sources can be used to power the switch. If one power input fails, the other power input
will power the switch.
Alarm Relay Connector
The Alarm Relay can be energized by the software or hardware under certain conditions.
It can then be used to trigger an external alarm circuit such as a light or sounding device.
This connector provides both Normally opened (NO) and Normally Closed (NC) dry con-
tact on the connector block, both are associated with the same relay.
Digital Input Connector
Two Digital Inputs are provided that can be used for the generation of alarms (SNMP trap,
energizing of on board Alarm Relay etc.).

Overview 8
IDS-409C Hardware Installation Guide
Port Status Indicators
Ethernet Port Status Indicators
Port Link / Speed (Green and Yellow LEDs)
SFP Status Indicators
Located on the associated Ethernet port connector
Port Link
State Description
Green 1000 Mbps
Green / Yellow 100 Mbps
Yellow 10 Mbps
On solid Port Link
Random blinking Port Link and Activity
Slow blinking Error disabled
Rapid blinking Port in Fast Setup Mode
State Description
Green Link
Green Flashing Link/Activity
Other manuals for IDS-409C
1
This manual suits for next models
1
Table of contents
Other Perle Switch manuals

Perle
Perle IDS-409 User manual

Perle
Perle IDS-409G User manual

Perle
Perle IDS-509-SFP User manual

Perle
Perle IOLAN SDG2 W User manual

Perle
Perle 07013340 Manual

Perle
Perle IOLAN SDG1 W Manual

Perle
Perle IDS-509PP8 User manual

Perle
Perle IDS-305G Manual

Perle
Perle IDS-305F Manual

Perle
Perle IDS-509FPP User manual

Perle
Perle IDS-509-2SFP Manual

Perle
Perle IDS-409C User manual

Perle
Perle IDS-509G2PP6 Manual

Perle
Perle RPS830 User manual

Perle
Perle IDS-105G User manual

Perle
Perle RPS820 User manual

Perle
Perle IDS-509GPP User manual

Perle
Perle IDS-205F User manual

Perle
Perle IDS-205F User manual

Perle
Perle IDS-409-SFP Manual