PerfectPrime AI200 User manual

AI200 Thermal Imaging
Face Recognition System
Instruction Manual

Contents
P. 1
1. Overview
2. Product Features
3. Product Specifications
4. Setting
5. Functions
6. Device Interface Indication
7. Size Description
8. Interface Descriptiones
5.1. Temperature calibration
5.2. Temperature measurement calibration
5.3. Parameter settings
5.4. Report statistics
5.5. A key to clear
5.6. Exit menu
2
3
4-5
6
7-11
7
8
9-10
11
11
11
12
13
14

1. Overview
P. 2
AI200 Thermal Imaging Face Recognition System is suitable for oce
areas, hotels, access gates, oce buildings, schools, shopping malls,
stores, communities, public services and management projects and
other places that require rapid access and temperature measurement.

2. Product Features
P. 3
• Imported high-precision and high-resolution thermal imaging modules
• High frame rate camera, high-denition pictures can be taken when the
human body is moving fast
• It comes with an 8-inch touch screen, which can be used directly
without an external display, or it can be connected to a large HDMI
screen
• Support simultaneous identication and temperature measurement of
20 people at the same time
• Easy to use, ready to use after power on, built-in black body
• It comes with high-denition alarm prompts, supports direct export of
reports, and stores 50,000 records oine
Precautions for use:
The temperature measurement ambient temperature range is
between 10℃to 35℃. This product is not used as a medical device.
Please turn on the electric heater for more than 15 minutes before
using this machine. This product can be used outdoors!

3. Product Specications
P. 4
Screen
Size 8 inches, IPS LCD screen
Brightness 500 LU
Resolution 800*1280 HD screen
Touch screen Capacitive touch screen
Camera
Resolution 200W, 1080P
Number of cameras 1
Type RGB camera
Aperture F2.0
Focal length 6mm
Focus Fixed
White balance Automatic
Wide dynamic Support
Interface
Video HDMI2.0 Type-A interface 1
Relay output 1 relay interface
Network Interface 1 RJ45 10M/100M adaptive Ethernet port, WIFI
4G interface Support (optional accessories)
USB 1 way USB interface

3. Product Specications
P. 5
Temperature measurement function
Face Detection Supports detection and tracking of
20 people at the same time
Temperature measurement 1 to 5 meters
distance
Temperature measurement ≤ ±0.3℃within 2 meters,
accuracy 3 meters to 4 meters ≤ ±0.4℃
4m to 5m≤ ±0.5℃
Temperature range 32℃~42.5℃
Resolution of temperature 206 X 150/320 X 240
measurement module
Direct release if the temperature Support
is normal
Body temperature alarm Support
value can be set
Wear a mask to identify Support
Body temperature over Support
temperature alarm
General parameters
Protection class
IP42, Certain dustproof and waterproof function
Power supply DC12V (±10%)
Operating temperature -10℃〜60℃
Working humidity 10%〜90%
Power consumption 10W MAX
Equipment size
Length255mm X Width170mm X Height210mm
Weight 4.3KG

4. Setting
P. 6
Click setting and enter password to go to the menu, see below pictures with
details(P1,P2)
P1
P2

5. Functions
P. 7
Temperature calibration:It can adjust the temperature measurement if
the temperature measurement function is inaccurate.
5.1. Temperature calibration
1. Click Temperature calibration and enter the temperature calibration
mode.
2. Let a person who has normal body temperature stand still in front of
the temperature measuring gun. (2-3 meters distance)
3. The temperature calibration will be automatically completed after
30 seconds.
Steps:

5. Functions
P. 8
When the temperature measurement is inaccurate, you can check
whether the temperature measurement point is deviated or not.
5.2. Temperature measurement calibration
1. Click[Temperature measurement calibration]and enter the
temperature measurement calibration mode.
2. Check whether the frame is in the middle of the face on the thermal
imaging interface. If there is a deviation, you can adjust the position
by clicking the four arrows (up, left, and right)
3. After the adjustment is completed, click [Exit Calibration] or click 6
times in the middle of the thermal imaging interface to complete
the temperature measurement calibration and exit. The system will
also automatically save and exit the calibration mode after 3
minutes.
Steps:

5. Functions
P. 9
The function can set high temperature threshold, temperature
compensation value, Relay on time, Record retention time days, IP
address, Mask detection, Turn on voice Broadcast, Language setting,
System setting, volume setting and USB ash disk upgrade.
5.3. Parameter settings
• High temperature threshold setting: Set temperature
measurement threshold, voice alarm over temperature.
• Temperature compensation value: Manually set the test body
temperature for calibration.
• Relay on time: The time interval between the opening and closing
of the relay.
• Record retention time days: store test data (support 0-3000 days,
ll in -1 for permanent storage).
• Mask detection: Turn on: When the person do not wear the mask, it
will take snapshot and save the data; If turn o the function it will do
not take picture and save the data.
• Turn on voice broadcast: Turn on: Voice broadcast; Turn o:Silent.
• Language switch: Switch system language.
• System setting: Jump to the system settings interface.
• Volume setting:Adjust the volume.
Table of contents