Perfect Prime TC2100 User manual

Digital Thermometer
TC2100
Instruction Manual

CONTENTS
P. 1
1. Safety Information
2. Product Overview
3. Meter Description
3.1 Component
3.2 Display
3.3 Keys Description
4. Setting Meter
4.1 SETUP Option
4.2 SETUP Option Setting
5. Using The Meter
5.1 Connecting thermocouple
5.2 Displaying Temperature
5.3 Data Hold
5.4 Viewing MAX, MIN and AVG
Readings
5.5 Use Oset value To Adjust
Temperature probe error
5.6 User Self-Calibration
6. Data Storage
6.1 Data Storage
6.2 Data Reading
6.3 Clearing Stored Data
7. Meter Maintenance
8.1 Replace Battery
8.2 Clean
8. Technique Data
................................................................... 2 - 3
.................................................................... 4
................................................................ 5 - 8
.............................................................................................. 5
........................................................................................................ 6
............................................................................... 7 - 8
..................................................................... 9 - 12
.......................................................................................... 9
................................................................... 9 - 12
............................................................... 13 - 15
............................................................... 13
.................................................................... 13
................................................................................................ 13
............................................................. 13
................................................................ 14
.................................................................. 14 - 15
.................................................................... 16 - 17
.......................................................................................... 16
......................................................................................... 16
.......................................................................... 17
................................................................ 18
..................................................................................... 18
........................................................................................................ 18
................................................................ 19 - 20

1.SAFETY INFORMATION
P. 2
In order to use the thermometer safely and correctly, please read this
manual carefully rst, especially the “Safety Information” part. It is
recommended to keep the manual at hand so that one can refer to it at
any time.
Warning indicates a situation/action which may cause danger to users. To
avoid any possible accidents or injury, please strictly follow the
procedures below:
1. Before using, check if there is any missing part or damages on the
case. Do not use if it is damaged.
2. Disconnect thermometer and thermocouple before opening the
meter case.
3. When the battery indicator appears, the battery should be
replaced.
4. If the product works abnormally, stop using it. Protective equipment
may be damaged. Send the meter to a designated repair site.
5. Do not use the product in explosive gas, vapor or dusty environment.
6. Do not apply voltage exceeding the rated voltage marked on the
product (30V).
7. Insulated thermocouple should be used.
8. Thermometer should be repaired only using manufacturers
replacement parts.
9. Do not use if the case is opened.
Warning

1.SAFETY INFORMATION
P. 3
Situations/actions which may cause damage to the meter are listed
below. To prevent damage, use the meter carefully.
Note-important safety information, refer to the instruction
manual.
1. Select appropriate thermocouple probes, function grade and
measuring range before using.
2. Ensure there is no dierence between two lines when using dual-line
measurement.
3. Do not charge the batteries.
4. Note the “+” & “-” polarities when installing batteries.
Caution
Conforms to UL STD. 61010-1,
Certied to CSA STD C22.2 NO. 61010-1
Complies with European (EU) safety standards
Electrical Symbols

This product includes thermocouple probes with microprocessor as the
temperature sensor. It has the following features:
2. PRODUCT OVERVIEW
P. 4
• Suitable for various thermocouples probes: K, J, T,E, R, S, N
• Dierent temperature units: °C, °F and K (Kelvin)
• Maximum, minimum and average value measurement
• Data hold
• Thermocouple deviation compensation
• Relative time display
• Auto power-o (can be set by users)
• Self-calibration (please refer to “User Self- calibration” section
carefully)
• Automatically and manually save data
• USB port
• Dual-line input (T1, T2)

P. 5
3. METER DESCRIPTION
3.1 Components
OFFSET SETUP REA D REC HOLD
T1 T2
K
T1-T2
°F
°C
mV
TYPE KJTERSN
USB MAX MIN AVG MEN
K
INTERVAL hou r:min
:
T1 T2
°F
CAL min: s ec
°C
POWER
HOLD
MAX
AVG
MIN
SETUP
THERMOMETER
1
2
-T1
+
3
-T2
+
4
5
6
1 2 3 4
Measure under normal temperature
Display
Key
4
5
6
USB port
Thermocouple probe T1 input
Thermocouple probe T2 input
1
2
3

3. METER DESCRIPTION
P. 6
3.2 Display
1 2 3 4 5 6 7
8
9
10
11
12
1314151617
18
19
20
Automatic power-off indicator
Low battery indicator: Battery
should be replaced.
Thermocouple measurements
include deviation value
Status setup indicator with
flashing display
Indicator to display saved data
Indicator to save data
automatically with flashing
display
Data hold state
Main display unit
Main display
1
3
2
4
5
6
8
9
7
MAX, MIN, AVGt
Indicator to save data
Auxiliary display unit
Auxiliary display
USB port
Time display
Indicate time display min: sec
Indicate calibrating state
Indicate auto-save time setting
Indicate time display hour: min
Indicate thermocouple probe
type
12
13
14
15
16
17
18
19
11
10
20

3. METER DESCRIPTION
P. 7
3.3 Keys Description
Select to display T1, T2 and T1-T2
(temperature dierence measurement) on
main/auxiliary screen
Unit selection: Celsius (°C),
Fahrenheit (°F), Kelvin (K)
View maximum, minimum and average
value. Press and hold to close
Data hold
To conrm, see user setting for details
To set, see user setting for details
T1/T2/
T1-T2
˚C/˚F/K
MAX/MIN
/AVG
HOLD
ENTER
SETUP
POWER Power on/o thermometer

3. METER DESCRIPTION
P. 8
Press and hold to open USB, press and hold
again to turn o
To change setting options/add
functions, see specic operation for details
To change setting options/reduce
functions, see specic operation for details
Read saved data
Save current data
PC-Link
▲
▼
READ
MEM
POWER Power on/o thermometer

1. Press the SETUP key to enter setup mode.
→“ SETUP ” symbol will ash on the screen.
2. Press again to switch setting states.
3. Save all previous settings before exiting.
→ If the meter is turned o in the process of saving settings, changes
will not be saved.
4. Changed settings will function immediately after exiting setup mode.
1. Press the SETUP key to enter the data storage interval setting mode
→“ SETUP ” will ash on the screen.
2. Use ▲ ▼ to change automatic data storage time interval.
3. Maximum interval time is 59:59.
4. Minimum interval time is 00:00.
→ 00:00 enables auto data storage function.
→ It can only be stored manually.
4. SETTING METER
P. 9
4.1 SETUP Option
4.2 SETUP Option Setting
A. Data storage interval setting (INTERVAL):
1. Enter thermocouple probe type setting mode.
2. Use ▲ ▼ to set thermocouple probe types: K, J, T,E, R, S, N.
B. Thermocouple probe type setting (TYPE):
Other manuals for TC2100
1
Table of contents
Other Perfect Prime Thermometer manuals

Perfect Prime
Perfect Prime TM0300 User manual

Perfect Prime
Perfect Prime TC2100 User manual

Perfect Prime
Perfect Prime TM118 User manual

Perfect Prime
Perfect Prime TM0819 User manual

Perfect Prime
Perfect Prime TC0370 User manual

Perfect Prime
Perfect Prime TC41 User manual

Perfect Prime
Perfect Prime TM0300 User manual

Perfect Prime
Perfect Prime TC0355 User manual