Opticon OPT-6125 Series User manual

User’s Manual
OPT-6125 Series
Handheld CCD Scanner
25-ULGPMU01-01
April 2002
Keyboard Wedge Interface
USB Interface
RS232 Interface
8 Olympic Drive
Orangeburg, NY 10962
Tel 845.365.0090
Fax 845.365.1251
www.opticonUSA.com


Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 3
Table of Contents
PART I CCD Scanning
General Information ...........................................4
Unpacking
Factory Technical Support
Part II Installation and SetUp
A. Installation –Wedge Interface ……………5
Reset all Defaults …………………………………………….6
Computer Type Selection … ............................... 6
InterCharacter Delay ..........................................7
B. Installation – RS232 Interface................ 8
RS-232C Communication Parameters ..................9
Baud Rate..........................................................9
Data Bits / Stop Bits / Parity..............................10
C. Installation – USB Interface...................11
_________________________________________
NOTICE
Opticon has taken every step to ensure that the
information included in this manual is accurate,
however we reserve the right to change any
specification at any time without prior notice.
_________________________________________
Part III Bar Code Menu Functions
Section A Programming the Scanner……………..12
Section B Symbology Selections ..................... 13
Enabling only a single symbology...................... 13
Enabling an addition symbology........................ 13
Setting Options for UPC-A/E ............................. 17
Setting Options for EAN-13 and -8 .................... 20
Code 39 Settings ............................................. 22
Codabar Settings ............................................. 24
2 of 5 Settings................................................. 27
MSI/Plessey Setting ......................................... 29
Code 128 Setting ............................................. 30
IATA Settings .................................................. 31
Section C: Universal Selections
Case Conversion .............................................. 33
Prefix Options.................................................. 34
Suffix Options.................................................. 36
Direct Input - Keyboard Keys ............................ 38
Direct Input - Characters ................................ 44
Direct Input - Control Characters ...................... 49
Read Mode Settings ......................................... 52
Trigger Settings............................................... 53
Beeper Options................................................ 57
Good Read Indicator (LED)............................... 59

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 4
Part I
General Information
The OPT-6125 Series CCD Scanners utilize state-of-the-art imaging technology similar to that found in digital cameras,
facsimile machines and video camcorders. The scanner images the bar code label, then converts the digital signals into data
the host computer can understand. By capturing the bar code image all at once, the scanner provides fast, highly accurate
reading.
Miniature surface mount electronics make up the CCD scanner's solid state construction. CCD scanners have no moving
mechanical parts and provide years of trouble-free operation.
This manual contains information on setting-up the scanner as well as programming various parameters of the scanner.
The OPT6125 scanner is available in several different interface configurations:
Keyboard Wedge Interface
RS232 Serial Interface
USB Interface
There is a specific section of this manual for installing each type of interface. Be sure you are using the section of the
manual that pertains to interface you are using.
Unpacking
Remove the scanner from its packaging and inspect it for damage. If the scanner was damaged in transit, call the dealer or
distributor from whom you purchased it. If you purchased it directly from Opticon, call Opticon Customer Service Dept. at
800-636-0090.
Factory Technical Support
If you have any questions or need assistance with programming your scanner call Opticon Technical Support at 800-636-
0090 please have the unit model number and several bar code labels readily at hand. The model number is located near the
connector end of the cable.
If the scanner must be returned, please contact Opticon to obtain an RMA (Return Merchandise Authorization) number prior
to returning the product. The Customer Service Dept. may be reached at 800-636-0090.
NOTE: Returned merchandise will not be accepted without a RMA number indicated clearly on the outside of the carton.

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 5
Part II Installation and SetUp
This section of the manual contains information on the physical installation of the scanner as well as certain programming options.
There is a separate section for each type of interface. Check to see which type of interface your scanner has and turn to that
section for information on installing the scanner
A.) Installation – Keyboard Wedge Interface
A "Y" connection cable is required for installation. The scanner is installed or "wedged" between the keyboard and the computer..
Your “Y” cable should have connectors for both a PS2 and AT type installation. The "Y" cable connects both the scanner and the
keyboard to the computer.
The scanner must match the type of computer being used. The default setting is for an IBM AT type computer. If this type does
not match the host computer, refer to the “Computer Type Selection” in the programming section that follows. If the connector
does not match the host compute remove the short cable section, reverse it and insert it in the other connector

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 6
Reset All Defaults – Keyboad Wedge Interface
Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most
applications, the scanner will work right out of the box without any need for additional programming. At any time you can return
the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below.
NOTE: (
Β
) A pointing finger indicates default settings throughout the following menus.
ZZ Start
Program Menu -[[-
UA XT Wedge -VB-
UB AT Wedge -VC-
UC PS2 wedge -VD-
ZZ End
Program Menu -[[-
Computer Type Selection (for Keyboard Wedge only)
The Keyboard Wedge interface scanner is designed to operate with an IBM personal computers and compatibles along with a
Macintosh PC's. Select the host computer type from the menu below.
NOTE: If the scanner has not been set to the correct host computer, the scanner will display random characters on the screen after
reading a bar code label.
ZZ
Start
Program
Menu -[[-
K0 IBM PC/XT -L1-
K1 IBM AT &
compatibles -L3-
Β
K3 HP Vectra -L!-
K4 Macintosh -L5-
ZZ
End
Program
Menu -[[-

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 7
Intercharacter Delay for Keyboard Wedge interface
The scanner may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun".
If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various
keyboard timing options listed in the menu to follow.
ZZ Start Program
Menu -[[-
LA No Delay -MB-
Β
LB Delay = 1 -MB-
LC Delay = 2 -MD-
LD Delay = 3 -ME-
LE Delay = 4 -MF-
LF Delay = 5 -MG-
LG Delay = 6 -MH-
LH Delay = 7 -MI-
LI Delay = 8 -MJ-
LJ Delay = 9 -MK-
LK Delay = 10 -ML-
ZZ End Program
Menu -[[-
+

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 8
B.) Installation – RS232 Interface
The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary.
There is a power supply jack on the RS-232 connector.
Installation is as follows:
1. Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external power
plug into the jack on the RS-232 connector.
2. Connect the power supply into an electrical outlet (110 V AC)
3. Turn on the power to the host computer. Make sure the communication parameters of the computer match those of the
scanner. The default communications settings are: 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking
4. Be sure the PC is in a program (such as WordPad) that will accept input from the serial port.
Reset All Defaults – RS232
Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most
applications, the scanner will work right out of the box without any need for additional programming. At any time you can return
the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below.
ZZ Start
Program Menu -[[-
U2 RS232 -V3-
ZZ End
Program Menu -[[-

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 9
RS-232C Communication Parameters
Handshaking Protocol
ZZ
Start
Program
Menu -[[-
P0 None -Q1-
Β
HP04 RTS/CTS +IQ15+
P3 ACK/NAK -Q!-
ZG Xon/Xoff -[H-
I0
Flow
Control
Time
Unlimited
-J1-
Β
I1
Flow
Control:
100ms -J2-
I2
Flow
Control:
200ms -J3-
I3
Flow
Control:
400ms -J!-
Baud Rate
K7 19200 -L8-
K6 9600 -L7-
Β
K5 4800 -L6-
K4 2400 -L5-
K3 1200 -L!-
K2 600 -L3-

Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner
Page 10
Data Bits / Stop Bits / Parity
L0 7 Data Bits -M1-
L1 8 Data Bits -M2-
Β
L5 1 Stop Bit -M6-
Β
L6 2 Stop Bits -M7-
L3 Even
Parity -M!-
L4 Odd
Parity -M5-
L2 Mark
No Parity -M3-
Β
ZZ
End
Program
Menu ,ZZ,
Table of contents
Other Opticon Scanner manuals
Opticon
Opticon F-100 SR User manual
Opticon
Opticon 25-ULGPMU01-01 User manual
Opticon
Opticon NLV-5201 User manual
Opticon
Opticon M-10 User manual
Opticon
Opticon OPI 4002 User manual
Opticon
Opticon OPC-3301n User manual
Opticon
Opticon OPN2002 User manual
Opticon
Opticon OPN2005 User manual
Opticon
Opticon OPN2002 User manual
Opticon
Opticon OPC-3301i User manual
Opticon
Opticon OPN2002 User manual
Opticon
Opticon RS-3000 User manual
Opticon
Opticon OPN 2001 User manual
Opticon
Opticon DFM 1000 User manual
Opticon
Opticon 25-WEDGE-06A User manual
Opticon
Opticon OPN 2001 User manual
Opticon
Opticon LMD 1135 User manual
Opticon
Opticon M-10 User manual
Opticon
Opticon L-46X User manual
Opticon
Opticon Laser Scanner User manual