CONTENTS
1 INSTALLATION PRECAUTIONS............2
1-1 BEFORE INSTALLATION................2
1-2 PARTS IDENTIFICATION................3
1-3 KNOCKOUTS..................................3
2 DETECTION AREA.................................4
2-1 OUTLINE OF DETECTION AREA...4
2-2 HOW TO REDUCE THE LONG
RANGE DETECTION AREA............6
2-3 HOW TO DEACTIVATE THE SHORT
RANGE DETECTION AREA............8
3 PREPARATIONS ..................................10
3-1 TRANSMITTER PREPARATION...10
3-2 BATTERY PREPARATION ............ 11
4 INSTALLATION (BATTERY AND
TRANSMITTER)...................................12
4-1 INSTALLING THE BATTERY.........12
4-2 INSTALLING THE TRANSMITTER
AND BATTERY BOX .....................15
5 INSTALLATION (BRACKET AND
MAIN UNIT) ..........................................16
5-1 INSTALLING WITH BRACKET......16
5-2 ADJUSTING THE VERTICAL
ANGLE...........................................18
5-3 INSTALLING WITHOUT
BRACKET......................................18
5-4 WIRING .........................................19
5-5 WALL TAMPER (OPTION) ............20
6 WALK TEST..........................................22
7 SETTING ..............................................22
8 LED INDICATION .................................26
9 SPECIFICATIONS ................................27
9-1 SPECIFICATIONS .........................27
9-2 DIMENSIONS................................28
HX-80NRAM Battery operated with 2 PIRs and
anti-masking
Battery operated
Battery saving logic
Compatible with most wireless transmitter
Long distance detection area (24.0 m)
Flexible detection area setting with plates and flaps
Unique pyro element
Intelligent AND logic
Dual signal processing logic
Vegetation sway analysis logic
Digital anti-masking
•
•
•
•
•
•
•
•
•
•
NO.59-1620-0
INSTALLATION INSTRUCTIONS
High Mount
Outdoor Detector
HX-80NRAM
High Mount
Outdoor Detector
HX-80NRAM
- 1 -
HX-80NRAMEN.indd1HX-80NRAMEN.indd1 2010/08/209:18:412010/08/209:18:41

1INSTALLATION PRECAUTIONS
1-1
BEFORE INSTALLATION
Warning Failure to follow the instructions provided with this indication and improper
handling may cause death or serious injury.
Caution Failure to follow the instructions provided with this indication and improper
handling may cause injury and/or property damage.
The check mark indicates recommendation.
The nix sign indicates prohibition.
Warning Warning Caution
Do not repair or modify produc
t Keep product away from water Mount the unit scurely
Mounting height Keep the detector parallel to the ground.
Consider the direction a person is approaching from, as well as the detection area.
Install the detector in a place where it is free from false alarm factors. For example:
Sunlight and reflection•Heat source•Objects moving in the wind•
2.5 m – 3.0 m
(8'2" – 9'10") Parallel Tilt
- 2 -
HX-80NRAMEN.indd2HX-80NRAMEN.indd2 2010/08/209:18:422010/08/209:18:42

1-2
PARTS IDENTIFICATION
(Transmitter and battery are not included.)
1-3
KNOCKOUTS
Bracket base Main unit
Bracket
LED indicator
Lock screw* (M4 ×35 mm)
Lens
Base Terminals
Shaft cover
Cover
Lock screw
Anti-masking infrared LED
Screw (4 ×20 mm)
Battery box
Accessories
Battery leads Velcro tapes Dummy battery
Alarm cable
PIR1
(Do not touch)
PIR2
(Do not touch)
For wall fastening/bracket fastening
(installation pitch 83.5 mm (3.29"))
For main unit fastening
Adjustment screw
BracketMain unit
(Off-the-shelf) Universal
magnet switch
install position
For bracket
Up-Down lock screw
Wiring Hole
For wall
fastening
For switch
box fastening
Do not touch
Up-Down
lock screw
Wiring
knockout
Wiring sponge pad Wiring Hole
Screw kit
For joint For wall mounting
Screw (4 × 20 mm) Screw (4 × 20 mm)
*Lock screw attached on bracket base
- 3 -
HX-80NRAMEN.indd3HX-80NRAMEN.indd3 2010/08/209:18:432010/08/209:18:43

2DETECTION AREA
a
b
d
g
i
h
j
C
2-1
OUTLINE OF DETECTION AREA
Plate 2
Flap fix position
indicator Plate fix position
indicator
Upper flap
Plate 1
Lower flap
- 4 -
HX-80NRAMEN.indd4HX-80NRAMEN.indd4 2010/08/209:18:432010/08/209:18:43

b
a
ef c
jg dhi
b
a
ef cjg dhi
0.5
1.5
2.5
2.5 m (8'2")
(m) 4 8 12 16 20 24 (m)
1.0
6
4
2
8
10
2.0
3.0
3.0 m (9'10")
(m)(ft.) 4 8 12 16 20 24 (m)
10 20 30 40 50 60 70 80 (ft.)
10 20 30 40 50 60 70 80 (ft.)
10 20 30 40 50 60 70 80 (ft.)
6
4
2
8
(ft.)
1.0
0
3
3
0
1.0
Top View
Side View
(m)(ft.) 4 8 12 16 20 24 (m)
DETECTION AREA (factory default)
Caution>>
Adjust 1 click (1.25° upward) for 3.0 m (9'10") height installation. (Refer to 5-2)•
Caution>>
Adjust 2 clicks (2.5° upward) for 2.5 m (8'2") height installation. (Refer to 5-2)•
- 5 -
HX-80NRAMEN.indd5HX-80NRAMEN.indd5 2010/08/209:18:432010/08/209:18:43

2-2
HOW TO REDUCE THE LONG RANGE DETECTION AREA
To adjust the LONG range of detection, set the upper and lower flaps as follows:
a
b
d
g
i
h
j
C
Flap fix position indicator
Upper flap
Lower flap
1Pull out the flap.
a
b
g
i
C
Note>>
If the lower flap is located at the factory default
position, slide it out with your thumb.
2Move the flap to the position that
corresponds with the desired detection
distance.
a
b
g
i
C
3Push the flap until it clicks into position.
a
b
g
i
C
- 6 -
HX-80NRAMEN.indd6HX-80NRAMEN.indd6 2010/08/209:18:432010/08/209:18:43

Factory default
Factory default
a
c
b
d
2
3
4
3.0m(9'10")
6.5m(22')
5m
3.0m(9'10")
13m(42'8")
5m 10m
118m(60')
5m 10m 15m
3.0m(9'10")3.0m(9'10")
10m(32'10")
5m
MASK
MASK
MASK
MASK
Upper position: a, Lower position: Factory default
Upper position: a, Lower position: b
Upper position: c, Lower position: b
Upper position: c, Lower position: d
PIR long range detection area reduction
The detection distance in the following table can be limited by combining the positions of the
flap.
Use the following table to determine the positions of the upper and lower flaps that set the
required max. detection distance.
NOTES:
1. The distance may vary due to environmental conditions.
2. Always walk test the detector to confirm the detection distance.
NOTE: Use only the following combinations for the flap settings.
24.0 m
(80')
c
a
bd
N.A.
N.A.
13.0 m
(42'8")
18.0 m
(60')
N.A. 10.0 m
(32'10")
6.5 m
(22')
N.A.
12
34
Factory
default
Lower
Upper
Factory
default
- 7 -
HX-80NRAMEN.indd7HX-80NRAMEN.indd7 2010/08/209:18:442010/08/209:18:44

2-3
HOW TO DEACTIVATE THE SHORT RANGE DETECTION AREA
To adjust the SHORT range of detection, set the upper and lower plates follows:
Plate 2
Plate fix position indicator
Plate 1
* Plate 1 and 2 are identical.
a
b
d
g
i
h
j
C
1Remove the plate.
a
b
g
i
C
2Insert the plate into the position
determined by the required masking
distance until it clicks.
a
b
g
i
C
3If any plate is not used, place it in the
storage position.
a
b
g
i
C
Note>>
Be careful not to lose the plates.
- 8 -
HX-80NRAMEN.indd8HX-80NRAMEN.indd8 2010/08/209:18:442010/08/209:18:44

g
i
jh
N.A.
3
N.A.
1
N.A.
Factory
default
2
4
N.A.
PIR short range detection area deactivation
Use the following table to determine the positions of the plates that set the required masked
area.
NOTE: Use only the following combinations for the plate settings.
g
i
h
j
Lower
Upper
Not used
Not used
1
3.0m(9'10")
24m(80')
5m 10m 20m
2
3.0m(9'10")
24m(80')
5m 10m 20m
3
3.0m(9'10")
24m(80')
5m 10m 20m
4
3.0m(9'10")
24m(80')
5m 10m 20m
MASK
MASK
MASK
MASK Upper position: Factorydefault, Lower position: j
Upper position: i, Lower position: j
Upper position: i, Lower position: h
Upper position: g, Lower position: h
- 9 -
HX-80NRAMEN.indd9HX-80NRAMEN.indd9 2010/08/209:18:452010/08/209:18:45

3PREPARATIONS
To use the HX-80NRAM, first prepare transmitters and batteries.
First check the following flowchart.
3-1
TRANSMITTER PREPARATION
Transmitters can be installed in one of two positions according to their size as follows.
122
33
80
140
15
22
• Battery preparation
Is it possible to
accommodate the
transmitter in the space
between Base and Main
unit (Refer to 3-1)?
Change the transmitter.
Is the battery in the transmitter
CR123, CR2, or 1/2AA?
It is possible to share the
batteries of HX-80NRAM.
Prepare the required batteries
which are the same type as
used in the transmitter.
Refer to
“Battery
Sharing” in
3-2.
It is not possible to share the
batteries of HX-80NRAM.
Prepare the required batteries
for HX-80NRAM.
Refer to
“Non Battery
Sharing” in
3-2.
• Transmitter size • Battery type • Reference
Yes Yes
No
No
Transmitter
Battery box
Transmitter
Battery box
Case 1) 122 × 50 × 33 mm Case 2) 80 × 50 × 22 mm
- 10 -
HX-80NRAMEN.indd10HX-80NRAMEN.indd10 2010/08/209:18:452010/08/209:18:45
Other manuals for HX-80NRAM
1
Table of contents
Other Optex Security System manuals
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual