Omega 871A User manual

http://www.omega.com
e-mail: [email protected]
®
User’s Guide
871A and 872A
Digital Thermometers
eed for
ntrol?
s & Assemblies
Only model 871A has
CE certification

Servicing North America:
USA: One Omega Drive, Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700
e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928 FAX: (514) 856-6886
e-mail: [email protected]
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM
Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico and
Latin America: Tel: (95) 800-TC-OMEGASM FAX: (95) 203-359-7807
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 06 0993344
e-mail: [email protected]
Czech Republic: Ostravska 767, 733 01 Karvina
Tel: 42 (69) 6311899 FAX: 42 (69) 6311114
e-mail: [email protected]
France: 9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX: (33) 130-699-120
Toll Free in France: 0800-4-06342
e-mail: [email protected]
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0130 11 21 66
e-mail: [email protected]
United Kingdom: 25 Swannington Road, P.O. Box 7, Omega Drive,
ISO 9002 Certified Broughton Astley, Leicestershire, Irlam, Manchester,
LE9 6TU, England M44 5EX, England
Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611
FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488
e-mail: [email protected]
omega.com
TM
OMEGA
®
OMEGAnetSM On-Line Service Internet e-mail
http://www.omega.com [email protected]
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is
constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the
CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected applications.

TABLE OF CONTENTS
MODEL 871A AND MODEL 872A
DIGITAL THERMOMETERS
SECTION PAGE
SECTION 1 INTRODUCTION .................................................................. 1
1.1 General Description ................................................................... 1
1.2 Features ..................................................................................... 1
2.1 Accessory Items......................................................................... 1
SECTION 2 INSTALLATION .................................................................... 2
2.1 Unpacking.................................................................................. 2
2.2 Battery Installation ..................................................................... 2
SECTION 3 OPERATION ......................................................................... 3
3.1 Controls and Indicators.............................................................. 3
3.2 Operating Procedure.................................................................. 5
SECTION 4 SERVICE INFORMATION .................................................... 5
4.1 Verification Check...................................................................... 5
4.1.1 Functionality Check ................................................................... 5
4.1.2 Accuracy Check......................................................................... 6
4.2 Calibration for Model 871A ........................................................ 6
4.2.1 Equipment Needed .................................................................... 6
4.2.2 Environmental Conditions.......................................................... 6
4.2.3 Setup.......................................................................................... 7
4.2.4 Calibration Procedure ................................................................ 7
4.3 Calibration for Model 872A ........................................................ 8
4.3.1 Equipment Needed .................................................................... 8
4.3.2 Environmental Conditions.......................................................... 8
4.3.3 Setup.......................................................................................... 8
4.3.4 Calibration Procedure ................................................................ 9
4.4 Disassembly for Model 871A and Model 872A.........................10
4.5 Troubleshooting Guide .............................................................11
4.5.1 DC Voltage checks Model 871A ...............................................12
4.5.2 DC Voltage Checks Model 872A ..............................................12
4.5.3 Waveform Checks Model 871A ................................................13
4.5.4 Waveform Checks Model 872A ................................................13
SECTION 5 SPECIFICATIONS FOR MODEL 871A
AND MODEL 872A .............................................................13
5.1 Parts List ...................................................................................16
i

SECTION 1 INTRODUCTION
1.1 GENERAL DESCRIPTION
The OMEGA® Model 871A and Model 872A Digital Thermometers are
ultrasensitive hand held instruments. Low power LSI devices combined
with a large 0.6" (15 mm) LCD, deliver reliability, extended battery life, and
an extremely readable readout. One nine volt battery will deliver 100 hours
of continuous operation.
The 871A and 872A are operationally identical except for minor differences
related to each model’s thermocouple input: Model 871A is designed for
use with type K (Chromel-Alumel) thermocouples; Model 872A is designed
for use with type J (Iron-Constantan) thermocouples.
Cold junction electronic circuitry in the Model 871A and Model 872A
automatically compensates for ambient temperature changes. A special
integrating A/D converter corrects for thermocouple non-linearity during
each digitization cycle. The resulting conformity to the standard
thermocouple voltage table is within 1ºC over the entire measurement span of
the instrument.
Although the 871A and 872A are ideal for temperature measurement in the
field, they also function well as bench instruments when equipped with the
optional tilt stand. The Model 871A and Model 872A provide dual inputs,
selectable scales (ºF/ºC), 1.0º and 0.1º resolution, and an analog output.
The versatile dual input configuration permits two point temperature
measurement such as those required in process monitoring. The analog
output allows interfacing with chart recorders or data acquisition system’s
functioning as an electronic ice-point reference.
1.2 FEATURES
• Wide temperature range • Dual thermocouple inputs
• Selectable scales (ºF/ºC) • Analog output
• 0.1º and 1.0º resolution • Heavy duty construction
• 0.25% accuracy
1.2.1 ACCESSORY ITEMS
SC-GG-[*]-30-36-SMP-M Thermocouple sensor (supplied with
unit) if purchased separately.
KS-871 Tilt stand
SC-800 Soft carrying case
880-A2 Deluxe carrying case
U9VL 9 V lithium battery
SMP-[*]-M Subminiature thermocouple connector, male
SMP-[*]-F Subminiature thermocouple connector,
female
OS-201-1 2 oz. jar of high thermal conductivity paste
for fast surface measurements
*Insert thermocouple type: J for Model 872, K for Model 871
1

SECTION 2 INSTALLATION
2.1 UNPACKING
Remove the Packing List and verify that all equipment has been received. If there
are any questions about the shipment, please call OMEGA Customer Service
Department at 800-622-2378 or (203) 359-1660.
The following items are included:
Quantity Description
1 871 or 872 Digital Thermometer
2 Beaded Wire Thermocouples
1 TAS Transition Adapter
1 9 Volt Alkaline Battery
1 Operator’s Manual
Upon receipt of shipment, inspect the container and equipment for any sign of
damage. Take particular note of any evidence of rough handling in transit.
Immediately report any damage to the shipping agent.
NOTE
The carrier will not honor any claims unless all shipping material is
saved for their examination. After examining and removing contents,
save packing material and carton in the event reshipment is necessary.
2.2 BATTERY INSTALLATION
A 9 V battery is supplied with the instrument but not installed. To install the
battery, remove the cover from the battery compartment by sliding it off in the
direction of the arrow located on the battery cover. The battery connector snaps
on and off the terminals of the battery. Improper installation of the battery will
cause the connecting wires to be severed by excess strain. Proper installation
requires that the battery be positioned in such a manner (see Figure 2-1) that the
leads protruding from the boot of the battery connector face toward the outside
of the battery compartment. If the instrument is going to be stored for a long
period of time or in a high temperature environment, remove the battery to
prevent damage due to leakage.
WARNING
Turn the model 871/872A off and disconnect the input probes before
replacing the battery. Put the cover back into place on the battery com-
partment before resuming use of the instrument.
2

Figure 2-1. Battery Installation
SECTION 3 OPERATION
The Model 871A is designed to work with any type K thermocouple probe or sen-
sor, fitted with an OMEGA miniature thermocouple connector SMP-K-M or industry
equivalent.
The Model 872A is designed to work with any type J thermocouple probe
or sensor, fitted with an OMEGA miniature connector SMP-J-M or
industry equivalent.
3.1 CONTROL AND INDICATORS
Figure 3-1 and Table 3-1 illustrate and describe the controls and indicators on the
871A and 872A.
Figure 3-1. Model 871A Controls and Indicators
*Model 872A has same controls and indicators, only range selections differ.
3

TABLE 3-1
MODEL 871A AND MODEL 872A
CONTROLS AND INDICATORS
ITEM CONTROL/INDICATOR FUNCTION
1. ON/OFF switch Turns unit on or off.
2. Scale and range selector Allows user to select: ºF or ºC scale,
any of four possible thermocouple
ranges, and 1.0º or 0.1º resolution.
3. Thermocouple selector Allows user to read either of two
thermocouples by simply turning
the dial.
4. Thermocouple input jacks Allows direct connection of two
thermocouples to the unit via an
OMEGA miniature male connector.
5. Analog output jack, The analog output is a nonlinearized,
+mV OUT and -mV OUT cold junction compensated, amplified
thermocouple output. (Not isolated
from selected TC input.) Use a
recorder to monitor temperature or
a sensitive DMM to make higher
resolution reading. Refer to mV
output specifications for mV output
to temperature ratios.
6. Low battery indicator When the battery level is low, BAT
will appear in upper left corner of
the display. Battery should then be
replaced to avoid error erroneous
readings due to battery failure.
7. Overrange/open When an overrange indication or
thermocouple indication open thermocouple condition exits,
a 1 followed by blanked digits will
appear in the display.
4

3.2 OPERATING PROCEDURE
1. Turn power on.
2. Select scale and range (see Tables 3-2 and 3-3).
3. Select thermocouple TC1 or TC2.
4. Connect one or two thermocouples to the input jacks.
5. Connect a recorder to the analog output to monitor temperatures,
or connect DMM to make high resolution readings, if desired.
TABLE 3-2
MODEL 871A TEMPERATURE RANGE
TABLE 3-3
MODEL 872A TEMPERATURE RANGE
SECTION 4 SERVICE INFORMATION
4.1 VERIFICATION CHECK
4.1.1 Functionality Check
Attach the GG-TC-K-24-36-SMP beaded wire thermocouple probe
(supplied) to the Model 871A and the GG-TC-J-24-36-SMP beaded wire
thermocouple probe (supplied) to the Model 872A. Hold the sensor end
between two fingers. The reading should change from ambient to between
77º to 104º F (25º to 40ºC).
Range Span Resolution
200°F -40.0° to 199.9°F 0.1°F
2000°F -40° to 1999°F 1°F
200°C -40.0° to 199.9°C 0.1°C
1370°C -40° to 1370°C 1°C
Range Span Resolution
200°F -40.0° to 199.9°F 0.1°F
1400°F -40° to 1400°F 1°F
200°C -40.0° to 199.9°C 0.1°C
760°C -40° to 760°C 1°C
5

4.1.2 Accuracy Check
1. Prepare a pure-water ice bath (see paragraph 4.2.3, step 5).
2. Connect a thermocouple probe to input 1 of the unit.
3. Immerse the probe into the pure-water ice bath and allow ten
minutes for thermal stabilization.
4. Turn on the instrument and use Tables 4-1 and 4-2 to verify
that the readings on each range are within specification.
TABLE 4-1
MODEL 871A RANGE CHART
TABLE 4-2
MODEL 872A RANGE CHART
4.2 CALIBRATION FOR MODEL 871A
4.2.1 Equipment Needed
1. DC Voltage Calibrator with 1 ±0.01% of setting ± 20 µV accuracy.
2. 100: 1 divider: 1.98 kilohm and 20 ohm wirewound resistors with
0.02% ratio accuracy or better.
3. OMEGA TRC III Ice Point Reference Chamber or distilled water ice
bath.
4. OMEGA type K TRP Reference Probe or make a thermocouple transi-
tion junction (see paragraph 4.2.3).
4.2.2 Environmental Conditions
To meet all specifications, the conditions for calibration should be an
ambient temperature 23º ± 1ºC; relative humidity less than 80%.
Range Allowable Reading
2000°F 32° ± 2°
200°F 32.0° ± 1.8°
1370°C 0° ± 1°
200°C 0.0° ± 1.0°
Range Allowable Reading
1400°F 32° ± 2°
200°F 32.0° ± 1.8°
760°C 0° ± 1°
200°C 0.0° ± 1.0°
6

4.2.3 Setup
(Refer to Figure 4-1.)
1. To make a thermocouple transition junction, silver solder a piece of
copper wire to each (type K) thermocouple wire and insulate the
junction with a waterproof jacket.
2. Connect the thermocouple wires from the type K transition junction to
an OMEGA miniature thermocouple connector SMP-K-M.
3. Plug in the miniature connector to input TC1 of the Model 871A.
4. Connect the copper wires to the 100:1 divider (see Figure 4-1) with the
copper/wire (positive) junction connected through the 1.98 kilohm
resistor, to the dc calibrator positive terminal.
5. Prepare a distilled water ice bath as follows:
a. Drill a hole in the cap of a Dewar flask or ThermosTM to accommodate
the transition junction.
b. Firmly pack the flask with pea-size ice chips made from distilled
water and then fill the flask with distilled water.*
c. Replace the melted ice with more ice while removing excess water.
d. Place cap on the flask and insert the transition junction into the
flask. Allow 20 minutes for temperature stabilization.
*Using tap water may cause inaccuracies due to contaminants.
*The 20Ωresistor must be held at a uniform
temperature during calibration.
Figure 4-1. Calibration Setup for Model 871A
4.2.4 Calibration Procedure
It is not necessary to disassemble the case for calibration. All adjustments
are accessible by removing the covers shown in Figure 4-2.
1. Remove the battery and trimmer compartment covers from the Model 871A.
2. Turn the Model 871A on and perform the calibration adjustments listed
in Table 4-3. 7
This manual suits for next models
1
Table of contents
Other Omega Thermometer manuals

Omega
Omega OS-821 Series User manual

Omega
Omega HH64 User manual

Omega
Omega OMEGASCOPE OS520 User manual

Omega
Omega CYD201A Series User manual

Omega
Omega OS550A User manual

Omega
Omega HH501AK User manual

Omega
Omega HH2001A User manual

Omega
Omega HH370 User manual

Omega
Omega A12P User manual

Omega
Omega HH40 Series User manual

Omega
Omega OS3700 series User manual

Omega
Omega HH804 User manual

Omega
Omega OS685 User manual

Omega
Omega CL3512 User manual

Omega
Omega DP465 User manual

Omega
Omega HH504 User manual

Omega
Omega HH11B User manual

Omega
Omega HH501BK User manual

Omega
Omega RDXL4SD User manual

Omega
Omega OMEGASCOPE OS520 User manual