OAKWORKS PerformaLift Series User manual

OAKWORKS®
PerformaLift Series
4-Section Electric
Salon Top
2-Section Lift-Assist
Backrest Top
USER MANUAL
www.OAKWORKS.com · 717.235.6807
1-Section Flat Top

© Copyright 2021
OAKWORKS®, Inc.
Printed in U.S.A.
All rights are reserved. No part
of this document may be
photocopied, reproduced or
translated to another language
without prior written consent
of OAKWORKS®, Inc.
OAKWORKS®is a registered
trademark of OAKWORKS®, Inc.
Notice
The information contained within
this document is subject to change
without notice and should not
be construed as a commitment by
OAKWORKS®, Inc.
OAKWORKS®, Inc. encourages
requests for technical
specifications and the like
documentation to ensure accuracy.
The appropriate documentation is
available upon request.
OAKWORKS®, Inc. shall not be
liable for incidental or
consequential damages in
connection with or arising out of
the furnishing, performance, or use
of this document and the program
material which it describes.

TABLE OF CONTENTS
Product Use Description......................................................................................................... 1
Important Safety Instructions
Symbol Identification ..................................................................................................... 1
Safety Instructions ......................................................................................................1-2
Product Description & Photo
4-Section Electric Salon ................................................................................................ 3
Control Operation - Electric Salon................................................................................. 4
2-Section Lift-Assist Backrest........................................................................................ 5
Control Operation - Lift Assist Backrest ........................................................................ 6
1-Section Flat Top ......................................................................................................... 7
Control Operation - Flat Top ......................................................................................... 8
Installation
Grounding...................................................................................................................... 9
Directions for Use
Moving the Table......................................................................................................... 10
Leveling the Table ....................................................................................................... 10
Lift-Assist Backrest Adjustment................................................................................... 11
Locking Casters Use (Option) ..................................................................................... 11
Removing Top Pad...................................................................................................... 12
Adjustable Breast Comfort (ABC) System (Option) .................................................... 13
Integrated Heated Top (Option) .................................................................................. 14
QuickLock Face Rest (Accessory Option) .................................................................. 15
Adjustable Side Arm Rest (Accessory Option - Salon Only) ...................................... 16
Boiance Shelf Support (Accessory Option)................................................................. 17
Bluetooth Speaker (Accessory Option) ....................................................................... 18
LED Lighting (Accessory Option) ................................................................................ 19
Table Reset Procedure - Hand Control....................................................................... 20
Table Reset Procedure - Foot Control ........................................................................ 20
Set Zero Height ........................................................................................................... 21
Cleaning & Disinfection
Recommended Cleaners/Disinfectants ....................................................................... 22
Cleaning Process ........................................................................................................ 22
Inspections & Maintenance .................................................................................................. 23
Warranty Information............................................................................................................ 23
Model Number & Serial Number .......................................................................................... 24
Specifications
Environmental Conditions............................................................................................ 25
Electrical Specifications............................................................................................... 25
Contact Information .................................................................................................back cover

This symbol, when used in this manual and on product labels, represents a caution warn-
ing. Be sure to read and comply with all precautions and warnings.
This symbol, when used in this manual and on product labels, warns against an electrical
shock hazard. Be sure to observe and comply with all warnings.
This symbol, when used in this manual or on product labels, indicates a Protective Earth
(Ground) Terminal.
This symbol, when used in this manual or on product labels, indicates the date of manu-
facture of the device.
This symbol, when used in this manual or on product labels, indicates alternating
current (AC).
This symbol, when used in this manual or on product labels, indicates direct current (DC).
This symbol is used to indicate that the operator should consult the user manual.
~
----
PRODUCT USE DESCRIPTION
Oakworks PerformaLift Series offers a variety of positioning capabilities for massage therapists and spa
professionals of all specialties. On these multifunctional professional tables the practitioner can perform
numerous protocols with ease and comfort. The fully electric PerformaLift Series is especially effective
when professional protocols require specific positioning for the client. While the client receives comfortable,
relaxing support, the comfort level of the therapeutic professional is enhanced by superior ergonomics.
It is intended to be operated by Massage Therapists in a professional environment. No special
training is required but a review of the following Safety Instructions is important for the safety of
the operator and client. The massage professional should read and understand this entire man-
ual before use with a client. There are no known contraindications to the use of this equipment.
The PerformaLift Series should not be used in any other manner than that described within this manual. Use
of any unnecessary force or unauthorized procedures could result in injury to practitioner, client or equipment.
SYMBOL IDENTIFICATION
CAUTION
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
The use of accessories, transducers, and cables other than those specified by the manufacturer, may result in
increased emissions or decreased immunity of the table.
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS
1
UL 2601-1
CSA C22.2NO.601.1
IEC 60601-2(2001-09)
CCUSUS
LL
II
SS
TT
EE
DD
R
UL 2601-1
CSA C22.2 NO.601.1
IEC 60601-2(2001-09)
CCUSUS
LL
II
SS
TT
EE
DD
R

The Table is designed to be a stand-alone table. This table must not be modified or incorporated into any other
equipment.
As with any moving mechanism there are potential pinch points around and underneath the table. It is the responsi-
bility of the operator of this equipment to insure that bystanders are not in the area below or around this equipment
during operation.
Proper operation of this equipment is very important for the safety of the operator, client, and any other/ individu-
als in the area of this equipment. Directions for use of this equipment are described in this manual. The operator
should read these sections carefully.
Weight Limit: (Client and accessories) 550 lbs. (250 kg) Do not exceed.
Adjustable Breast Comfort (ABC) System Weight Limit - 100 lbs. (45 kg.) Do not sit on the ABC System. Do not
place foreign objects into the ABC System. Only use as intended. For safety of your client, use a cloth sheet
between the ABC System and your client.
Be certain that the table is completely lowered without any tilt being present prior to discharging an ambulatory cli-
ent. The client may lose balance and fall.
This table is not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous
oxide.
Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
Do not lift table by the table top. This can damage the table.
When lowering the table, make sure there is nothing underneath the table top that can impede motion (like
stools, cabinets, accessory parts, cleaners, etc)
Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recom-
mended by the manufacturer.
Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
WARNING
To reduce the risk of burns, fire, electric shock or injury to persons:
1. Unplug this furnishing from the electrical outlet before cleaning.
2. Unplug from outlet before adding or removing parts.
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use at 717.235.6807.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
DANGER
Risk of electric shock - Connect this furnishing to a properly grounded outlet only. See Grounding Instructions in this
manual.
Electrical Shock Hazard - The power supply/control module is located on the lift frame. No user serviceable parts
are inside. Refer servicing to qualified personnel. Unplug wall plug prior to contact with any cables connected to the
power supply.
2
IMPORTANT SAFETY INSTRUCTIONS

PerformaLift
4-Section Electric Salon
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 20”-34” (51-86 cm.) Height Range
Motion 2 Powered ±15º Trendelenburg/ Reverse
Trendelenburg
Motion 3 Powered 0-70º Backrest
Motion 4 Powered 0-30º Foot Rest
Foot Control All powered motions
Hand Control All powered motions
Table Voltage Options 100V/60Hz - 230V/50Hz
Table Capacity 550 lbs. (250 kg.) (client and accessories)
Widths 29” (74 cm.), 31” (79 cm.), or 33” (84 cm.)
Length 73” (185 cm.)
Padding 4” (10 cm.) or 6” (15 cm.) Aerocel Foam™
Table Weight*250 lbs. (113 kg.)
OPTIONS
Adjustable Breast Comfort (ABC) System
Wood Finishes
Locking Casters
Integrated Heated Top
ACCESSORIES
QuickLock Face Rest
Boiance Shelf Support
Side Arm Rests
For electrical specs, see Specifications section.
3

CAUTION
CONTROL OPERATIONS - ELECTRIC SALON TABLES
Do not sit on backrest or footrest sections. The hood area under the backrest top is not designed for
storage. DO NOT use this area for holding anything. Damage can occur to the table.
The OAKWORKS®PerformaLift Electric Salon Tables offer trendelenburg, height, backrest, footrest and
optional ABC positioning with electronic ease. Operate the foot and hand control as shown below to raise
or lower the trendelenburg, height, backrest or footrest functions of the table.
PRODUCT DESCRIPTION
Height Down
Head End Down
Head End Up
Backrest Down Footrest Down
Backrest Up Footrest Up Height Up
MEM1 MEM2
Use any of the top 8 buttons to orient the table in
a favorite position. To store the current position
in memory, press the MEM button twice (double
click). Two audible beeps will confirm. To recall
a stored position, press & hold the MEM button.
MEMORY FUNCTION USE
Backrest Up Backrest Down
Memory 1 Function Memory 2 Function
Zero Gravity Position
Fully Flat/Fully Down
Footrest Up Footrest Down
Head End Up Head End Down
Height Up Height Down
ABC Down
ABC Up
ABC Option ABC Option
ABC SYSTEM UP
ABC SYSTEM DOWN
ABC Down
ABC Up
Optional
Optional
4

PerformaLift
2-Section Lift-Assist Backrest
PRODUCT DESCRIPTION
STANDARD SPECIFICATIONS
Motion 1 Powered 20”-34” (51-86 cm.) Height Range
Motion 2 Powered ±15º Trendelenburg/ Reverse
Trendelenburg
Motion 3 Manual 0-80º Backrest
Foot Control All powered motions
Hand Control All powered motions
Table Voltage Options 100V/60Hz - 230V/50Hz
Table Capacity 550 lbs. (250 kg.) (client and accessories)
Widths 29” (74 cm.), 31” (79 cm.), or 33” (84 cm.)
Length 73” (185 cm.)
Padding 4” (10 cm.) or 6” (15 cm.) Aerocel Foam™
Table Weight*230 lbs. (104 kg.)
OPTIONS
Adjustable Breast Comfort (ABC) System
Wood Finishes
Locking Casters
Integrated Heated Top
ACCESSORIES
QuickLock Face Rest
Boiance Shelf Support
For electrical specs, see Specifications section.
5

MEM1 MEM2
AB C ABC
CAUTION Do not sit on backrest section. The hood area under the backrest top is not designed for storage.
DO NOT use this area for holding anything. Damage can occur to the table.
The OAKWORKS®PerformaLift Lift-Assist Backrest tables offer trendelenburg, height, and optional ABC
positioning with electronic ease. Operate the foot and hand control as shown below to raise or lower the
Trendelenburg, height and optional ABC functions of the table.
PRODUCT DESCRIPTION
CONTROL OPERATIONS -LIFT-ASSIST BACKREST
Height Down
Head End Down
Head End Up Height Up
ABC SYSTEM UP
ABC SYSTEM DOWN
ABC Down
ABC Up
Optional
Optional
Use any of the top 8 buttons to orient the table in
a favorite position. To store the current position
in memory, press the MEM button twice (double
click). Two audible beeps will confirm. To recall
a stored position, press & hold the MEM button.
MEMORY FUNCTION USE
Memory 1 Function Memory 2 Function
Head End Up Head End Down
Height Up Height Down
ABC Down
ABC Up
ABC Option ABC Option
6

PerformaLift
1-Section Flat Top
PRODUCT DESCRIPTION
For electrical specs, see Specifications section.
STANDARD SPECIFICATIONS
Motion 1 Powered 20”-34” (51-86 cm.) Height Range
Motion 2 Powered ±15º Trendelenburg/ Reverse
Trendelenburg
Foot Control All powered motions
Hand Control All powered motions
Table Voltage Options 100V/60Hz - 230V/50Hz
Table Capacity 550 lbs. (250 kg.) (client and accessories)
Widths 29” (74 cm.), 31” (79 cm.), or 33” (84 cm.)
Length 73” (185 cm.)
Padding 4” (10 cm.) or 6” (15 cm.) Aerocel Foam™
Table Weight*230 lbs. (104 kg.)
OPTIONS
Adjustable Breast Comfort (ABC) System
Wood nishes
Locking Casters
Integrated Heated Top
ACCESSORIES
QuickLock Face Rest
Boiance Shelf Support
7
Other manuals for PerformaLift Series
2
Table of contents
Other OAKWORKS Massager manuals

OAKWORKS
OAKWORKS SISSEL Portal Pro User manual

OAKWORKS
OAKWORKS PORTAL LIGHT User manual

OAKWORKS
OAKWORKS PORTAL LIGHT User manual

OAKWORKS
OAKWORKS PORTAL PRO User manual

OAKWORKS
OAKWORKS Clodaghl User manual

OAKWORKS
OAKWORKS Portal Pro User manual

OAKWORKS
OAKWORKS ButterflyCushion User manual

OAKWORKS
OAKWORKS Marina User manual

OAKWORKS
OAKWORKS Antigua User manual

OAKWORKS
OAKWORKS Celesta Gemini CLODAGH User manual