Nira TEMP User manual

820.009 Rev 01
Quick Start & Instructions For Use

1
Search for 'NIRA Temp' in the Google Play Store, OR
open: https://play.google.com/store/
apps/details?id=com.dermalphotonics.
nirahealthmonitor&hl=en_US
Download the NIRA Temp app for Android.
Search for 'NIRA Temp' in the Apple App Store, OR
open: https://apps.apple.com/app/id1519242962
Download the NIRA Temp app for iOS.
Get a real-time look at your temperature and get notified at
the first sign of an abnormal temperature.
For iOS User:
Download the iOS App
For more instructions on NIRA Temp app, please go to page 6.
Peel the patch and place the device on clean, dry skin
under the armpit. The sensor should touch the skin.
2. Stick To Activate
3. Monitor In Real Time
For Android User:
Download the Android App
Once connected to the NIRA Temp App, assign the
device to yourself or a loved one.
1. Connect & Assign User
Samantha P.

2
NIRA Temp measures under-the-arm “axillary” temperature and display it in the NIRA Temp app.
Welcome to NIRA Temp, a medical-grade wearable temperature monitor.
NIRA Temp is a Bluetooth® wearable smart thermometer with disposable patches. The device senses,
records and transmits body temperature via Bluetooth®. Temperature information from the sensor is
monitored using a smart device (Apple® or Android™ with Bluetooth® Version 4.1 or higher capability
running the NIRA Temp app). This product is suitable for ages 3 and up.
The wireless thermometer, Model 2, is a battery-operated electronic device with an intended use of
measuring human body temperature. This device is reusable and intended for armpit temperature readings
for people of ages 3 and up.
Important: Read instructions carefully before use. High,
prolonged fever requires medical attention. If symptoms
persist, contact your healthcare provider.
Important: Read the instructions for use before using
NIRA Temp
The battery is non-rechargeable and is intended to operate at least 12 months of normal use. During his
time the battery voltage will be gradually reduced, which is normal and expected. The current battery level
is displayed in the mobile app screen in remaining percentage units and the device will stop operation
soon after the battery level will reach 0%. As battery discharges, the LED brightness will go down, but
the strength of the BLE signal and thermometer accuracy will not be affected. The NIRA Temp accuracy is
verified for the entire range of possible battery voltages and meets the specification as long as device is
capable to measure and transmit the information to the mobile device.
Introduction to NIRA Temp
Intended Use
Temperature Measurement
Battery Life

3
The device uses color coding to aid the user:
Warning – Prompt response by user is required. (Temperature
exceeds personal Baseline related Warning Level)
Alarm – Immediate response by user is required. (Temperature
exceeds user defined limit, the default value is 98.78°F
(37.1°C)).
Normal - (temperature is less than user defined warning limit,
the default value is 95.36°F - 97.8°F (35.2°C-36.56°C)).
Alert Levels
What's included (Normal Package)
What's included (Refill Package)
Name Number
NIRA Temp thermometer 1
Adhesive patches 30
Quick start guide for the device 1
Getting Started Instruction 1
Name Number
Adhesive patches 90
ID: 934819
ID: 1CD6E9
ID: 0754C7 99.1°F
ID: 934819
ID: 1CD6E9
ID: 0754C7 99.1°F
ID: 934819
ID: 1CD6E9
ID: 0754C7 99.1°F

4
Wear NIRA Temp all day for the full benefits of 24/7 temperature tracking.
Peel the adhesive patch and center the device onto the patch with the sensor (metal piece) side up.
Apply the patch with the device onto clean, dry skin in the center of the armpit. For best results, use
NIRA Temp on a shaven armpit.
Ensure that the device is fully covered by the patch. The sensor should touch the skin.
The device should be fully enclosed in the armpit when your arm is relaxed along your side.
Temperature measurements can be affected by cold ambient temperatures.
Dampen the patch with lukewarm water prior to slowly removing the patch from the skin.
It may take up to 10 - 20 minutes after application for the device to warm up to display your real-
time temperature in the NIRA Temp app.
During warm up, your graph displayed in the app may be blue.
If your phone has been off, in sleep mode or away from device, it may take a few minutes for the
app to sync and display your real-time temperature and history temperature in table and graphic
forms.
We recommend enabling Background App Refresh in iOS and having phone plugged in power at
night.
If you experience skin irritation from the adhesive patch, alternate armpits or contact a medical
professional.
Regular Operation
State BLE advertisement Visual indication
Standby None Green and Yellow LED, reduced brightness,
once in 6 second
Standby (low battery at or below 25%) None Yellow and Red LED, reduced brightness, once
in 6 seconds
User Connection Once in 3 seconds, 0 dBm All 3 LED, once in 3 seconds
Monitoring, normal temperature Once in 9 seconds, +4 dBm Green LED, once in 3 seconds
Monitoring, low grade fever Once in 9 seconds, +4 dBm Yellow LED (full brightness), once in 3 seconds
Monitoring, high grade fever Once in 9 seconds, +4 dBm Red LED, once in 3 seconds
Troubleshooting
Things To Note
For Best Results

5
When using this product always follow these basic safety precautions to ensure that the device accurately
reads temperature and to avoid skin irritation. Failure to follow these precautions could result in inaccurate
temperature readings, or could result in skin irritation and mild discomfort.
The NIRA Temp device is intended for use by a single individual. As such, it does not require disinfection
after detachment from the body and attachment with a new adhesive patch. It can be cleaned for hygienic
purposes such as removal of sweat and odor.
To clean, use liquid soap, cool or warm tap water (temperature from 20°C - 30°C). For best results,
dampen a cotton ball, pad, or paper towel in soapy water, clean the front and back of the device for 15-
30 seconds, rinse the device in running water for another 15-30 seconds, and dry using a clean paper
towel or air dry for 10 minutes.
In the case that the same device is shared with multiple individuals, disinfect it by using rubbing alcohol
(60 - 90% solution) or alcohol wipes at room temperature (20°C - 30°C) after cleaning. To disinfect, dip
the cotton ball or pad or in alcohol or use an alcohol wipe, wipe down the device with a clean paper towel
to ensure that no excess alcohol is present, and let it air dry for 5 minutes or until no alcohol is left on the
surface.
DO NOT use the device for any other purpose besides measuring human body temperature.
DO NOT place the device on wounds, sores or abrasions.
DO NOT drop or throw the device.
DO NOT use the device if it has been damaged.
DO NOT attempt to take apart the device; there are no user serviceable parts.
Patch Adhesive may irritate skin. Contact doctors if irritations persists.
No modification of this equipment is allowed.
The device or its components are not intended to be serviced, or repaired.
The patches are intended ONLY for single use.
The device disposal at the end of its life should be in compliance with local laws and regulations.
CHOKING HAZARD -Small parts. Not for children under 3 years.
Alcohol is a flammable liquid. Do not use alcohol for disinfection or any other purposes near an
open flame!
Device is powered by a 3V non-rechargeable battery. Not intended to be recharged, serviced,
replaced, or repaired.
Portable RF communications equipment (including peripherals such as antenna cables and external
antennas) should be used no closer than 30 cm (12 inches) to any part of the NIRA Temp, including
cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment
could result.
Warnings and Precautions
Cleaning and Disinfection

6
Once the app is
downloaded and installed,
tap to open the app.
Tap NEXT to go through
features of NIRA Temp.
Allow or decline to
anonymously share data
with health organizations.
3
1 2
Instructions for NIRA Temp App
Start the App
Start the App
Permission to Share Data
Introduction of Features
Temp

7
Use existing account
information to login or tap
sign up to create a new
account.
You can go to People tab
to add a new person if you
do not have any person
added to your account.
Enter information and
agree to terms of use to
create a new account.
1
2
3
Create Account
Login
Add a Person
Sign Up

8
Follow the instructions to
find the QR code on the
device. Then tap next.
Hold the phone as indicated
by the graphic to scan the
QR code. Tap scan to enter
camera interface.
Place camera over the QR
code to scan.
Message will appear that
the device has been paired
successfully.
SKIP TO PAGE 10 IF
YOU HAVE PAIRED
SUCCESSFULLY THROUGH
THIS METHOD
34
1 2
Pair the Device
Find the QR code
Scan the QR code
Pair the Device with the QR code
Pair Successfully
Success!
Device with ID: E06F12267C46 is now paired

9
Apply device to skin to
activate. (see page 10)
Wait 3 to 5 min for the
device to reach normal
temperature in order for
the device to be scanned
by the app.
Tap "No QR Code? Pair
with Bluetooth" located on
the Pair Screen.
Message will appear that
the device has been paired
successfully.
Pair the Device via Bluetooth (Optional)
Pair the Device with Bluetooth
Scan the Device
Stick to Activate
Pair Successfully
3 4
1 2
Success!
Device with ID: E06F12267C46 is now paired
Other manuals for TEMP
1
Table of contents
Other Nira Thermometer manuals