Nexo P12-I User manual

DP4603-02-DI
P12-I
User manual

TABLE OF CONTENTS
Page 2/ 20 P12-I
TABLE OF CONTENTS
TABLE OF CONTENTS___________________________________________________________________ 2
WARNINGS ____________________________________________________________________________ 3
EQUIPMENT ___________________________________________________________________________ 4
DESCRIPTION__________________________________________________________________________ 5
PRESET_______________________________________________________________________________ 6
HF DIRECTIVITY________________________________________________________________________ 8
CROSSOVER FREQUENCY_______________________________________________________________ 8
ACCESSORIES _________________________________________________________________________ 9
ARRAY EQ____________________________________________________________________________ 14
MAINTENANCE________________________________________________________________________ 15
TECHNICAL SPECIFICATIONS ___________________________________________________________ 17
USER NOTES _________________________________________________________________________ 18
EU Conformity declaration
We,
NEXO SA
ZA DU PRE DE LA DAME JEANNE
60128 PLAILLY –France
Declare under our sole responsibility that the product
Type
Serial number
Loudspeaker
P12
On the product
Is in conformity with the provisions of the following directive
including all applicable amendments:
2014/35/UE (Low Voltage Directive)
Applied rules and standards:
Plailly, June 12th, 2019
EN 13155, EN 62368
Joseph CARCOPINO, R&D Director

WARNINGS
P12-I Page 3/ 20
WARNINGS
PRECAUTIONS
-
repairable part.
If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the
system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
The connection should be performed by qualified technician, by ensuring that power is off.
Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.
SAFETY INFORMATIONS
Read this manual before using the speaker.
Keep this manual available for further reference.
Observe all warnings and cautions.
Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual.
Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe
these rules may expose persons to potential wounds or even death.
Only use the system with accessories specified by NEXO.
Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions:
Mounting Precautions:
- Please select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of
damaging components.
- Do not place the system in an unstable position: it could fall accidentally.
- If cations are adapted and that its height does not exceed
.
Connection and Powering Precautions:
- Unplug connected cables before moving the system.
- Power off the system before connecting the system.
- When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the
amplifier first.
- If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the
system components to stabilize.
Please check regularly the system condition.
HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different
from one person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of
time. The OSHA (Occupational Safety and Health Administration) American Agency specified the following maximal exposures:
Number of Hours
Sound Pressure Level (dBA),
Slow Response
8
90
6
92
4
95
3
97
2
100
1 ½
102
1
105
½
110
¼ or less
115
WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
This symbol on the product or its packaging indicates that this product must not be treated as household waste.
Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste
electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent
potential negative consequences for the environment and human health, which could appear if this product was
not recycled. Recycling helps spare natural resources. For more information about the recycling of this product,
please contact your local city office, your household waste disposal service or your reseller.

EQUIPMENT
Page 4/ 20 P12-I
EQUIPMENT
3 locations for hanging, 1 on the back and on both sides.
WARNING: The depth of the M10 thread is 13mm (0.5 inch).
Assembly on distance rod or speaker stand
Place distance rod on the connector plate (M20) of the Sub.
Place PLADAPT on P12-I.
Put the assembly on the distance rod / monitor stand (diameter
of 35mm),
IMPORTANT
Speaker stand must be rated for P12 weight.
Speaker stand must always be installed on a horizontal surface.
Stand height and footprint must be defined to prevent assembly
from collapsing.
Ensure that audience is not allowed within a safety area which
radius is equal or higher than assembly height.
Test steadiness of the assembly by pushing in all directions.

DESCRIPTION
P12-I Page 5/ 20
DESCRIPTION
→The P12-I is a compact full-range coaxial speaker
→P12 HF Dispersion:
•60° - 60° with standard horn
•90° 40° with PNU-P12FLG9040
•PS with PNU-P12FLGPS (Asymmetrical Dispersion)
→P12 can be used alone or with L15 subwoofer
→The speaker is equipped with a cable gland (clamping range, ø5 to 12 mm), supplied with a fixed cable (HO7ZZ-F), 2 x
1.5mm2section, length 4m, outside diameter 8mm ±1mm.
→(+) Red / (-) Black
→Amplification
•The P12 speakers must be used with a NEXO processor to handle EQ, phase alignment, crossover and
excursion/thermal protection for the system loudspeaker. There are two NEXO processor series supporting the P12
speakers: NXAMP (4 channels) amplified processors and DTD processors (stereo + sub). DTD processors ensure
optimal performances when used with DTDAMP power amplifiers.
•The following table shows the number of P12 speakers and L15 subwoofers usable with each solution.
NXAMP4X1MK2(BRIDGED)
NXAMP4X2MK2
NXAMP4X4MK2
P12
Up to 2 per channel
Up to 2 per channel
Up to 4 per channel
L15
1 per channel
Up to 2 per channel
Up to 2 per channel

PRESET
Page 6/ 20 P12-I
PRESET
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
For the P12, the following setups are available:
→MAIN is the recommended setup for most FOH application, similar to previous firmware setup.
→MONITOR is recommended for monitor applications. Warning: this setup is a low latency setup and therefore its phase is not
compatible with other NEXO cabinets, including subs.
•P12 MON PA 6060, with high-pass at 60 or 85 Hz.
•P12 MON PA 9040, with high-pass at 60 or 85 Hz.
•P12 MON PA PSguide, with high-pass at 60 or 85 Hz
•P12 MAIN PA 6060, with high-pass at 60, 85 or 120 Hz.
•P12 MAIN PA 9040, with high-pass at 60, 85 or 120 Hz.
•P12 MAIN PA PSguide, with high-pass at 60, 85 or 120 Hz.
P12
Front of house and stage monitor applications

PRESET
P12-I Page 7/ 20
P12 + Sub
Stage monitor applications with Subs (OMNI or CARDIO modes)
Front of house applications with Subs (OMNI or CARDIO modes)

HF DIRECTIVITY
Page 8/ 20 P12-I
HF DIRECTIVITY
→The P12 speaker can be used in horizontal or vertical position.
→The standard horn is a 60° - ersion by adding a specific flange. Different
mounting possibilities and flange rotation allow to deal with every request.
Loosen the 2 screws, Remove the grille.
Remove the 4 HF Cap.
Place the flange, if necessary rotate it.
Magnets keep the flange in place.
When replacing the grille, ensure it is well positioned in the top blade before fasten the hooks with the screws.
CROSSOVER FREQUENCY
→60 Hz: Full range application.
→85 Hz: Use as « front fill » on stage, complementing a main system. Use with a NEXO subwoofer, e.g. L15.
→120 Hz: Long throw application.

ACCESSORIES
P12-I Page 9/ 20
ACCESSORIES
WARNINGS
All P12 accessories are specifically rated in agreement with structural computations.
Never use other accessories –including push-pins –when assembling P12 cabinets than the ones provided by NEXO: NEXO
will decline responsibility over the entire P12 accessory range if any component is purchased from different supplier.
PROHIBITED: P12 below P12 or P12 below L15 without dedicated accessory
VNU-BUMP (PNT-BUMP)
LiftBar, use with P12,
LIFTADAPT, WMADAPT.
Place VNU-BUMP on P12 (only use the
provided screws).
Tight properly
Refer to the Product Data Sheet.
VNU-HBRK535 (PNT-HBRK12)
Horizontal Cradle, use with P12,
CLADAPT, PLADAPT.
Place HBRK535 on P12, use only fasteners
provided.
Tight properly.
Refer to the Product Data Sheet.

ACCESSORIES
Page 10 / 20 P12-I
VNU-PLADAPT (PNT-PLADAPT)
Pole adapter, use with P12,
HBRK535, VBRK12.
Place VNU-PLADAPT, use only fasteners
provided.
Tight properly.
Refer to the Product Data Sheet.
PNU-VBRK12 (PNT-VBRK12)
Vertical Cradle, use with
CLADAPT, PLADAPT.
Place VBRK12 on P12, use only fasteners
provided.
Tight properly.
Refer to the Product Data Sheet.
Table of contents
Other Nexo Speakers manuals

Nexo
Nexo ePS6-EN54 User manual

Nexo
Nexo PS8 User manual

Nexo
Nexo VNI-WB02 User manual

Nexo
Nexo P15 Under 2xL18 Rigging System User manual

Nexo
Nexo DP4335-01-DI User manual

Nexo
Nexo ePS10 User manual

Nexo
Nexo DP4535-02-DI User manual

Nexo
Nexo MSUB18-PW User manual

Nexo
Nexo ePS6 User manual

Nexo
Nexo L15 User manual