DESCRIPTION
The microStar™is a microwave motion sensor with Human
Presence Radar™ (HPR™) for activating all types of
automatic doors. The sensor is capable of wide or narrow
detection patterns and provides a relay output for simple
interfacing with a door controller or other type of device.
INCLUDED IN THE BOX DIMENSIONS
(1) microStar™Motion Sensor
(1) Wire Harness
(2) Mounting Screws
(1) Installation Instructions
SPECIFICATIONS
MECHANICAL INSTALLATION
NOTE: Remember to follow these safety precautions:
Shut off power to the automatic door before wiring sensor.
Always ensure wiring is located clear of any moving door parts to avoid damage.
Always be aware of pedestrian traffic. Keep people clear of the work area when setting up or testing the door.
Comply with all applicable building codes and safety standards (ANSI A156.10).
Model
microStar™
Input Power
12-24V AC/DC +/-10 %
Power Consumption
3.5W Maximum
Output Contacts
Form C, Rated at 1 Amp
Output Hold Time
Max. 5 Seconds
Temperature Rating
-22°F to 158°F (-30°C to 70°C)
Weight
<1 lb.
Microwave Frequency
24.125 GHz +/- 50 MHz
Max. Mounting Height
15’ (4.6M)
Color
Flat Black Cover
Material
ABS Plastic Cover & Base
Compliances
FCC Part 15

Page 2 of 6 microStar 032021-V1
①Remove the sensor cover:
Remove the cover of the microStar by placing the blade of a
small screwdriver in the notch in the right side of the cover as
shown at right. Once the sensor is attached to the header the
cover can be removed in this same manner.
② Peel and attach the self-sticking mounting
template (C) at the desired location. Drill 3
holes noted on template (1 wire passage
hole, 2 screw pilot holes).
③ Insert mounting screws partially into holes. Route the wire harness through the wire passage hole as shown. Install
the microStar onto the mounting screws and tighten.
CONFIGURATION
① Select the proper antenna orientation for the application:
② To change the orientation of the antenna, perform the following:
To remove the antenna: position index and middle fingers on the back of the PCB, position thumb on the top
edge of the sensor holder. Squeeze thumb toward fingers. Remove the sensor from holder.
Rotate antenna 90ºto change zone orientation and then re-install antenna into the holder.
NARROW
WIDE

Page 3 of 6 microStar 032021-V1
Important –When the antenna is in the narrow orientation and the wires exit at the bottom of the PCB, ensure
wires are routed under the holder and remain clear of the front of the antenna.
▪The wires must never be in the front of the antenna or improper performance may occur.
Once completed, the antenna holder can be
rotated and/or tilted to achieve proper position
of the detection field per the requirements of the
application.
② Set the dipswitches per the application:
DIPSWITCH SETTINGS
LEFT
OFF
6. NOT USED
6. NOT USED
5. FAIL-SAFE OFF
5. FAIL-SAFE ON
4. HPR OFF
4. HPR ON
3. NOT USED
3. NOT USED
2. DEPART
2. APPROACH
1. BI-DIRECTIONAL
1.UNI-DIRECTIONAL
Rotate left or right for
lateral angle adjustment
Rotate up or down for
tilt angle adjustment

Page 4 of 6 microStar 032021-V1
Fail-Safe:
oWhen enabled, the fail-safe function causes the output relay to energize as soon as the sensor is
powered on. The relay will then de-energize when the sensor is activated or when there is a power loss.
In this manner, a power loss causes the relay output to perform the same as if there was a detection. If
fail-safe is disabled, the relay remains de-energized when power is applied and will only energize upon
an activation.
HPR:
oWhen the Human Presence Radar is enabled, the sensitivity of the radar is increased to allow detection
of extremely slow movements within the field of detection.
Depart/Approach:
oWhen configured for DEPART, the sensor will only detect activity that is moving away from the sensor. In
APPROACH mode, the sensor will only see activity that is approaching the sensor.
Bi-Directional / Uni-Directional:
oThe Bi-Directional function allows the sensor to see movements from all directions within its detection
zone. In Uni-Directional mode, the sensor only detects movements that are towards the sensor.
WIRING
① Wire the sensor according to the application and plug the harness into the sensor upon completion. Wire
connections are shown below.
POWER-ON
① Upon completion of the mechanical installation, configuring the sensor, and all necessary wiring, apply voltage to
the sensor (12 to 24 volts AC or DC).
The LED located at the lower left side of the antenna will illuminate green when the sensor is ready for use.

Page 5 of 6 microStar 032021-V1
Once the sensor is ready for use, one can begin walk-testing and adjusting the lateral angle and tilt angle as
desired.
HELPFUL HINT:
To quickly adjust the pattern, press the Reset button
and then press & hold the Install button 3 seconds (the
LED will flash orange to confirm). This puts the
microStar into the install mode allowing the installer to
walk test the pattern from several different directions
without activating the door. Simply watch the LED
while approaching the pattern Green = No detection;
Red = Detection. Once the desired pattern is achieved
press the reset button and the microStar will reset to
normal operating mode.
RE-INSTALL COVER
① Replace the cover by engaging the left side first and then gently
snapping the cover into place.
② After re-installing the cover, be sure to walk-test the sensor again to
ensure there has been change in the detection zone.
RELATED PRODUCTS
PN: MSRC:
microStar Rain Cover
PN: MS-BDB
microStar Mounting Bracket

Page 6 of 6 microStar 032021-V1
QUALIFIED INSTALLERS
When applying this product to an automatic pedestrian door, MS Sedco recommends this product only be installed by technicians
who are certified inspectors by the American Association of Automatic Door Manufacturers. All installations shall be compliant to
applicable nationally recognized performance standards.
RMA PROCEDURE
Upon confirmation of a failed product, an RMA form must be filled out online prior to returning the product
to MS Sedco.
Go To: https://mssedco.com/return-repair-policy-form/
Or scan the QR code with your smartphone to go directly to the online form.
TERMS OF WARRANTY
MS SEDCO, Inc. guarantees this product to be free from manufacturing defects for three years from the date of
shipment from our factory. If, during this period, the product fails to operate and has not been tampered with or
abused, the unit can be returned prepaid to the factory and be repaired free of charge. After three years, the unit will be
repaired for a nominal service charge. Limited warranty is in lieu of all other warranties, expressed or implied, including
any implied warrantability of merchantability. No representative or person is authorized to assume for MS SEDCO any
other liability in connection with the sale of our products. All warranties are limited to the duration of this written
limited warranty. In no event shall MS SEDCO be liable for any special, incidental, consequential or other damage arising
from any unclaimed breach of warranty as to its products or services.
COMPANY CONTACT
MS SEDCO
7898 Zionsville Rd.
Indianapolis, IN 46268
Phone: 317-842-2545
www.mssedco.com
Table of contents
Other MS Sedco Accessories manuals

MS Sedco
MS Sedco MicroStar blue User manual

MS Sedco
MS Sedco DH97 User manual

MS Sedco
MS Sedco INTERSECTOR SDLC User manual

MS Sedco
MS Sedco DH400 User manual

MS Sedco
MS Sedco DH94D User manual

MS Sedco
MS Sedco DH100-CT User manual

MS Sedco
MS Sedco INTERSECTOR User manual

MS Sedco
MS Sedco ID20 User manual

MS Sedco
MS Sedco SmartWalk XP User manual