MITECH TOWER MAGNUS User manual

TOWER MAGNUS
DUAL IR+MW TECHNOLOGY BARRIERS
Available in terminal and bi-directional versions
Installation and user manual
MADE IN ITALY

TOWER MAGNUS Installation and user manual Page 2 of 32
Index
Introduction
and warnings
Page 3
Main components and accessories
Pages 4
-5
General
installation instructions
Page 6
Mounting
options
Page 6
Installation
solutions
Page 10
•
Wall mounting (GAR WL bracket) ………………………………………………………………………………………… . 6
•
Ground mounting (GAR GR base) ………….….……………………………………………………………………….…. 7
Receiver
and transmitter boards Page 12 -
13
Power
supply
Page 14
Alignment
Page 15-16-
17
Settings
and programming
Page 18
•
Description of signalling leds ……………………………………………………………………………………………….. 18
•
Description of jumper settings
.…………………..............................................................................19
Fixing the
barrier to the base
Page 8
Tamper
height adjustment, inserting the cover and closing the barrier
Page 9
Microwave
device Pages
from 20 to 29
•
Introduction …………………………………………………………………………………………………………………………. 20
•
Features and non-detection zones ……………………………………………………………………………………….. 20
•
Receiver board (RX ) …………………………………………………………………………………………………………….. 21
Description of dip -switch and terminal board
•
Transmitter board (TX ) …………………………………………………………………………………………………………. 22
Description of dip -switch and terminal board
•
Installation ……………………………………………………………………………………………………………………………. 23
•
Manual configuration by dip-switch ……………………………………………………………………………………... 23
•
Control through software (RS485) …………………………………………………………………………………………. 25
Warnings
and OR –AND function
Page 30
Technical
features and consumption
Page 31

TOWER MAGNUS Installation and user manual Page 3 of 32
Introduction
and warnings
INTRODUCTION
TOWER MAGNUS are the dual technology perimeter
barriers with utmost
reliability and efficacy. In combination with the
appropriate accessories, they can be camouflaged in
a lighting pole that combines aesthetics and
functionality with a reliable safety device. It is
precabled and ready for installation, composed of a
transmitting and a receiving unit. The transmitter
emits a codified sequence of infrared beams and high
frequency electromagnetic waves directed to the
respective receiver. The microwave device uses
planar antennas of new generation and military
derivation with reduced size owing to the absence of
the cumbersome antenna dish.
TOWER MAGNUS are also indicated for harsher
environments and weather situations (low
temperatures, fog, humidity, wind gusts) thanks to
the built-in automatic temperature control device
and the disqualification system and sturdy aluminium
structure
WARNINGS
•Use shielded cables.
•Observe the minimum distances between the
Tx and Rx barriers (see table on page 15).
•In areas subject to intense fog, for
distances longer than 80 m, it is advisable
to break the tract.
•Power the device using the 13.8 Vdc
stabilised voltage only.
•It is mandatory to switch on the
temperature control system for both
internal and external installations (24Vac).
•The installation should be performed by
qualified personnel.
MITECH is not responsible for damages
and / or barrier malfunctions
caused by incorrect installation
and / or improper use.

TOWER MAGNUS Installation and user manual Page 4 of 32
Main
components
4
3
7
6
5
2
1 Part
Quantity
Description
1 1 Aluminum support bar
2 1 IR polycarbonate tube
3 1 Upper cap
4 1 Lower cap
5 1 Tamper
6 1 Power supply
(optional)
7 1 Ground fixing base (GAR GR)
or wall fixing bracket (GAR WL)
Boards, optical groups, microwave
and heating system
Terminal version RX or TX
Motherboard 1 (RX or TX)
Expansion boards 2 (RX or TX)
Tamper boards 1 (RX or TX)
Optical groups 3 (RX or TX)
Microwave 1 (RX or TX)
Heating resistors 3
Bi-directional version
Motherboard 1 couple
(1 RX + 1 TX)
Expansion boards 2 couples
(2 RX + 2 TX)
Tamper boards 1 couple
(1 RX + 1 TX)
Optical groups 3 couples
(3 RX + 3 TX)
Microwave 1 couple
(1 RX + 1 TX)
Heating resistors 3 couples

TOWER MAGNUS Installation and user manual Page 5 of 32
Accessories
IMAGE CODE DESCRIPTION
GAR GR
(standard)
Base for ground fixing
200 x 210 mm
Ø 33 cm
GAR WL
Bracket for wall mounting
(200 x 210 mm)
GARPOW Dual power supply, 1 for barrier
(if required it is installed up)
GAR LAMP CO or WH
Globe light fixture with lamp holder (E27)
Diameter: 32 cm
Available colours: white (WH) and cognac (CO)
GAR LUMYA
Embedded light fixture (white colour) with
lamp holder
Height: 25 cm - E27
GAR PRCAP Anti-climbing pressure cap
TW CAMCAP Universal camera support

TOWER MAGNUS Installation and user manual Page 6 of 32
General
installation instructions
1.
2.
3.
4.
After installing the barrier, make sure that it is perfectly closed with the watertight
covers supplied.
Make sure that the path between the sensors is free and that there are no obstacles
that could affect the communication between the optical groups of the transmitters and
receivers (i.e. branches, plants, leaves, etc. that could interfere with the beams).
Verify that the optics of the transmitter and receiver units are not exposed to direct
sunlight at dawn and sunset.
Do not use switching power supplies that might cause electrical disturbances .
Mounting
options
barriers
may be mounted in two ways:
- w
ith a specific wall mounting bracket (code: GAR WL)
- w
ith a specific ground mounting base (code: GAR GR)
Wall
mounting (GAR WL bracket)
Drill 4 holes of Ø 8 mm in the wall, level with the bracket fixing holes.
Insert M8 steel gussets (not supplied) and fix the bracket.
20 cm
20 cm
20 cm
FRONT VIEW SIDE VIEW
20 cm
TOP VIEW
Hole for cables passage Ø 32

TOWER MAGNUS Installation and user manual Page 7 of 32
Ground
mounting (GAR GR base)
FIXING WITH CLAMPS
This fixing method is the most secure.
Make a cement base in which to anchor the
clamps provided.
It is necessary to use a corrugated pipe Ø 20 mm
for passage of cables.
FIXING WITH
GUSSETS
Drill 3 holes of Ø 8 mm in the ground, level
with the base fixing holes.
Insert M8 steel gussets (not supplied) and
fix the base.
20 cm
20 cm
20 cm
FRONT VIEW SIDE VIEW
20 cm
TOP VIEW
Cables insertion hole Ø 32

TOWER MAGNUS Installation and user manual Page 8 of 32
Fixing the
barrier
BRACKET
M6X25
M6X20
LOWER CAP
Insert the lower cap into the base guide.
Insert the aluminium bar into the base
guide and into the relevant slot in the lower
cap.
Insert the connecting bracket between the
lower cap and the aluminum bar.
Screw 2 M6x20 screws through the
bracket and the base and 2 M6x25 screws
through the bracket and the bar.

TOWER MAGNUS Installation and user manual Page 9 of 32
Tamper height adjustment, inserting the tube and closing
the
barrier
Tamper height adjustment
Adjust the tamper height using the two
jagged edge washers A and B (see image).
Closing the barrier
Position the top cover and screw it to the
barrier using the supplied screws provided
with o-ring.
Inserting the tube
Insert the polycarbonate tube from above,
making it slide down into the slot and
inserting it into the lower cap.
A
B

Installation
solutions
TOWER MAGNUS Installation and user manual Page 10 of 32
4
SIDES PERIMETER PROTECTION
With bi
-directional barriers
4
SIDES PERIMETER PROTECTION
With terminal
barriers
3 SIDES PERIMETER
PROTECTION
With terminal and bi
-directional barriers
WARNING: ENSURE THAT THE barriers ARE INSTALLED IN A STRAIGHT ROW
For a correct positioning of the barriers, refer to the following diagram
(contact the supplier for more information)
TX RX/TX RX/TX RX
YES
TX RX/TX
RX/TX
RX
NO
TX RX/RX
TX/TX
RX
YES
Table of contents
Other MITECH Security System manuals
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual