Loveshaw MicroJet I User manual

Little David® Technician's Manual
MicroJet I™
MicroJet I Plus™
MicroJet II™
MicroJet III™
MicroJet III HC™
INK JET CODER
by
Trouble-Shooting Guide
PART NUMBER: CPM200-TSG

Loveshaw, an ITW Company
2206 Easton Turnpike, PO. Box 83
South Canaan, PA 18459
Tel: 1-800-962-2633 570-937-4921
Fax: 570-937-4016
www.Loveshaw.com
Loveshaw Europe A Division of ITW LTD.
Unit 9 Brunel Gate
West Portway Industrial Estate
Andover, Hampshire SP10 3SL
ENGLAND
Tel: 264-357511
Fax: 264-355964
Document revised September 2004. Copyright © 2003, 2004 Loveshaw, an ITW Company All rights reserved
worldwide.

Table of Contents
MICROJET Trouble-Shooting Guide iii
ntroduction ............................................................................................................. 1I
) Ink lamp stays on ............................................................................................... 2
A
) Ink lamp does not come on when ink container is empty.................................. 2
B
) Unit does not purge ............................................................................................ 3
C
) Heavy printing.................................................................................................... 3
D
) Weak print/output............................................................................................... 4
E
) Printing starts heavy and weakens when printing long messages ...................... 4
F
) Photocell LED(s) does not light......................................................................... 4
G
) Photocell LED(s) does not turn off.................................................................... 4
H
) Display does not come up.................................................................................... 5
I
) CPU losing date/time when unit is off ................................................................ 5
J
) Valve does not print but purges ......................................................................... 5
K
) Valves print but will not purge........................................................................... 5
L
) Pump does not run............................................................................................. 6
M
) Ink leaks from ink bottle cap ............................................................................. 6
N
) Product delay/character width changing on product.......................................... 6
O
) Ink not drying on product ................................................................................... 7
P
) Nozzle plate weeps ink ...................................................................................... 7
Q
) Nozzle blocked................................................................................................... 7
R
) Tubing loose on valve ports................................................................................ 8
S
) Unit locks up after installation ........................................................................... 8
T
) Tailing output..................................................................................................... 8
U
ow ink lamp/reservoir lead removal ...................................................................... 9
L
ir pump pressure adjustment................................................................................ 10
A
iagrams ................................................................................................................ 12
D
attery Replacement .............................................................................................. 25
B
ill of Materials / Quick Reference Chart ............................................................. 26
B
Warranty................................................................................................................. 28

MICROJET Trouble-Shooting Guide 1
Introduction
Head:
This document covers hardware procedures for the
Loveshaw MicroJet Printers which include MicroJet I,
MicroJet I Plus, MicroJet II, MicroJet III, and MicroJet
III HC. Procedures are described in a simple list form
keyed to hardware fault, so that technicians can quickly
diagnose and fix such problems.
( Personnal Protection Equipment such as safety
glasses and other protective gear should be worn
when servicing ink jet printers.)
NOTE: Refer to attached assembly drawings when troubleshooting. Further
assistance can be obtained by calling your local distributor or Loveshaw
factory service technician at 1-800-962-2633.
Head:

MICROJET Trouble-Shooting Guide 2
A) Ink lamp stays on
* New units shipped from the factory contain a solution that will cause the
lamp to remain on. This solution must be completely purged out, and ink
purged through, before the lamp will go out.
* Purge unit, light should go out.
* If lamp remains on, remove the two screw on the front cover.
* With power disconnected, look for broken wire at reservoir.
* If lamp remains on, remove tie wrap which hold wires to Power Supply
Board and lower the wire harness.
* Test resistance across pins 1 and 2 on side “A” of four pin connector.
Resistance across reservoir pins should measure approx. 1.5 meg. ohm (See
Troubleshooting Chart at end of this list.)
* If lamp remains on, call for service.
Head:
B) Ink lamp does not come on when ink container
is empty
* If lamp remains on, remove tie wrap which hold wires to Power Supply
Board and lower the wire harness.
* Test resistance across pins 1 and 2 on side “A” of four pin connector.
Resistance across reservoir pins should measure approx. 1.5 meg. ohm (See
Troubleshooting Chart at end of this list.)
Circuit should be open.
* Check resistance of lamp between pins 3 and 4 on four pin connector on
side “A”. Resistance should be 25 ohms. If circuit is open replace lamp. See
LOW INK LAMP/RESERVOIR LEAD REMOVAL procedure.
* Check voltage between pins 1 and 2 on four pin connector on side “B”. A
very small voltage of .075 volts DC should be present. If no voltage is
present, replace CPU assembly.
* Check voltage between pins 3 and 4 on four pin connector on side “B”.
Voltage should be 25 volts DC. If no voltage is present, replace CPU
assembly. (See Quick Reference Chart for part numbers.)
* If lamp remains out, call for service.
Head:

C) Unit does not purge
* Test pump pressure. Pressure should be between 2.0 and 3.0 psi. If
pressure is zero, proceed to step “M”.
* Check ink level in container and replace if empty.
* Check for kinks in tubing and replace, if necessary.
* Test for ink flow from brass cap/ink container: Crimp tubing going into
reservoir from ink container. Remove tubing from inlet of reservoir and test
for ink flow by loosening crimp (discharge into container and avoid getting
ink on circuit cards). If no flow is present, replace ink container and/or brass
cap.
* Test for ink flow from reservoir. Crimp tubing going into reservoir from
ink container. Remove tubing from inlet side of filter. Carefully loosen
crimp and test for ink flow (discharge into container and avoid getting ink on
circuit cards). If a weak ink flow or no flow is present, replace reservoir. See
LOW INK LAMP/RESERVOIR LEAD REMOVAL procedure.
* Test for ink flow from filter: Crimp tubing going into reservoir from ink
container. Remove tubing from inlet side or off-center port of valve.
Carefully loosen crimp and test for flow (discharge into container and avoid
getting ink on circuit cards). If a weak flow or no flow is present replace
filter.
Head:
D) Heavy printing
* Check dot size setting (<SIZE> key). Lower if needed.
* Check incoming voltage from transformer. Voltage between pins 1 and 2
on transformer connector should be approximately 20 volts AC (See
Troubleshooting Chart at end of this list.)
* Purge to remove air.
* Check individual valve adjustment (<MENU> then 8). Lower if needed.
* Test pump pressure (2.0_3.0 psi) if higher, adjust. See AIR PUMP
PRESSURE ADJUSTMENT procedure.
Head:
MICROJET Trouble-Shooting Guide 3

E) Weak print/output
* Check dot size; increase as needed.
* Check purge output; all nozzles to give a 2 inch stream of ink or greater.
* If weak printing continues, go to letter “C” testing ink flow.
Head:
F) Printing starts heavy and weakens when
printing long messages
* Purge for air removal.
* Check purge, which should be steady; if not, go to letter “C” testing.
Head:
G) Photocell LED(s) does not light
* Test photocell by placing a white piece of paper directly in front of unit;
LED(s) should come on. If not, turn photocell holder(s) gently from side to
side and note if LED light(s) come on; leave in position that lights LED(s);
slowly pull paper back from unit and note distance at which LED goes out;
should be 2 inches or more. If not, replace photocell . (See Quick Reference
Chart for part numbers.)
Head:
H) Photocell LED(s) does not turn off
* Check that there is no reflective material in front of unit. If so, the material
should be painted a “flat black” color (infrared does not reflect well off of a
flat black surface.)
* Turn photocell holder(s) gently from side to side and note if LED light
goes out.
* Power the unit off then on; LED light should be off, if not, look for ink or
water on board(s) or unit.
* If ink or water is on boards remove and flush/dry overnight. Retest next
day.
* LED light is on, and will not go out, replace CPU board (See Quick
Reference Chart for part numbers.)
Head:
MICROJET Trouble-Shooting Guide 4

I) Display does not come up
* Check if pump is running; if not, check that transformer is operating
properly. (See Troubleshooting Chart at end of this list.)
* If pump is running, check AC fuse under front cover and replace if blown.
* If fuse continues to blow, replace power supply board. (See Quick
Reference Chart for part numbers.)
* If fuse does not blow, test voltage at power board. If proper voltage is
present replace CPU.
* If proper voltage is not present, call for service.
Head:
J) CPU losing date/time when unit is off
* Reset and monitor for 24 hours with unit off.
* If retest fails, CPU battery must be replaced. See battery replacement
procedure.
* If CPU looses date/time with unit on, replace CPU.
Head:
K) Valve does not print but purges
* Plug a working valve in that position and test. If printing occurs, replace
valve. If no printing occurs, check ribbon cables, replace Valve, CPU or
Driver Board.
L) Valves print but will not purge
* Test continuity of purge switch with unit off and purge switch depressed.
Replace if defective; should be zero ohms.
* Test valve board resistor/diode for proper values (See Troubleshooting
Chart at end of this list.)
MICROJET Trouble-Shooting Guide 5

M) Pump does not run
* Remove transformer power cord from unit and check for proper AC
voltage at connector. (See Troubleshooting Chart at end of this list.)
Replace transformer if defective.
* Remove front cover and check electrical connectors on pump. If proper
voltage is present at pump and pump is not running, remove wires (2) going
to pump, and check resistance across pump coil (See Troubleshooting Chart
at end of this list.)
* If no voltage is present at pump connectors check transformer and AC
outlet.
N) Ink leaks from ink bottle cap
* Remove brass connector and check for presence of “O” rings on the under
side of brass connector and replace if missing or damaged.
* Tighten container cap.
* Reposition container and check for leaks.
* If leak continues, replace bottle with a new one and retest.
* If leak continues, replace ink bottle cap assembly.
O) Product delay/character width changing on
product
* Check the orientation of box to MICROJET — it must be perpendicular.
* Clean photocell filters with water, and check that both photocell LED
lights come on when product passes by. If photocell LED does not come on,
go to procedure “G”.
* Check to insure no extraneous spaces are inserted before or after text in
message. If so, delete extra spaces.
* If problem continues, check for dark colored bands on box. (Photocells
will not detect black). Test with a blank box.
* If product delay/character width continues to move, call for service.
MICROJET Trouble-Shooting Guide 6

P) Ink not drying on product
* Check dot size setting ( <SIZE> key); lower if needed.
* Check pump pressure should be between 2.0 and 3.0 psi. If pump pressure
is out of adjustment, see AIR PUMP PRESSURE ADJUSTMENT
procedure.
* Check to be sure box is not waxy or oily (make sure substrate surface has
not changed).
Q) Nozzle plate weeps ink
* Wipe nozzle plate with a damp paper towel and check to see if ink forms
on nozzle plate.
* If ink does not form on nozzle plate, print 5-10 boxes and check. If ink
forms, replace nozzle plate tubing.
* Remove valve at location generating weeping.
* Connect valve to a 9 volt battery and flush water into outlet post with a
syringe and a piece of .040 tubing.
* Replace valve and retest.
* Connect tubing to outlet of valve from the nozzle plate and purge
* Repeat backflush and purge if necessary
* If weeping persists, replace valve.
R) Nozzle blocked
* Remove tubing from center port of valve that supplies fluid to blocked
nozzle.
* Connect drain hose (from maintenance kit) to tubing attached to back of
nozzle plate.
* Place other end of drain tubing outside of unit and drain into a container.
* Place tubing end of syringe with cleaner, over orifice that is blocked and
apply pressure (you will see fluid move down drain tube).
* Continue flushing until tubing is clear of ink.
* Disconnect syringe and reconnect tubing to valve port.
* Purge and retest.
* Repeat if necessary.
* If nozzle is still blocked, replace the nozzle plate assembly.
Head:
MICROJET Trouble-Shooting Guide 7
S) Tubing loose on valve ports