LineEye LANIO Series User manual

LAN connection type IO controller
LANIO series
Manual
(3rd Edition)
The latest instruction manual is in the attached CD as PDF format.
LA-5R / LA-5P-P / LA-3R3P-P

1
Notice
Under the copyright laws, it is prohibited to reprint or duplicate any part or the whole of this
instruction manual without prior permission from LINEEYE CO., LTD. (“LINEEYE”)
All company and product names in this manual are trademarks or registered trademarks of their
respective companies.
The contents of this manual and specications of the products are subject to change without any
notice.
This manual has been designed and edited with great care to give you all necessary information. If
you have any questions, feel free to direct your inquiries to LINEEYE.
LINEEYE makes no warranty or guarantee, either expressed or implied with respect to its quality,
performance, merchantability, or tness for a particular purpose. LINEEYE shall not be liable
for direct, in-direct, special, incidental, or consequential damages resulting from any defect in the
product. The warranty and remedies set forth above are exclusive and in lieu of all others.
Thank you for your purchase of LANIO series. To use it correctly,
you are advised to read and understand this instruction manual
thoroughly. Keep this together with the warranty.
Introduction
Copyright 2007-2018 by LINEEYE CO., LTD. All rights reserved.

2
■■ Contents ■■
Chapter 1 Product Overview ............................................................................... 6
1-1.Overview of LANIO series.......................................................................................6
1-2. Unpacking and Product Composition......................................................................6
1-3. Panel Explanation ....................................................................................................7
1-4. Common Specication.............................................................................................8
Chapter 2 Setup and Installation.......................................................................... 9
2-1. Installation................................................................................................................9
2-2. Power supply..........................................................................................................10
2-3. Connection with a LAN network...........................................................................10
2-4. IP Address Assignment ..........................................................................................11
2-4-1. Setting by LANIOset..........................................................................................11
2-4-2. Setting by Device Installer .................................................................................13
2-4-3. Conguration by Telnet connection ..................................................................15
2-5. Note for external wiring ........................................................................................17
Chapter 3 LA-5R Usage.............................................................................19
3-1. LA-5R Overview ...................................................................................................19
3-2. I/O specication of LA-5R ....................................................................................19
3-3. External wiring example of LA-5R.......................................................................20
Chapter 4 LA-3R3P-P Usage .....................................................................21
4-1. LA-3R3P-P Overview............................................................................................21
4-2. I/O specication of LA-3R3P-P ............................................................................21
4-3. External wiring example of LA-3R3P-P...............................................................22
Chapter 5 LA-5P-P Usage..........................................................................23
5-1. LA-5P-P Overview ................................................................................................23
5-2. I/O specication of LA-5P-P .................................................................................23
5-3. External wiring example of LA-5P-P....................................................................24
Chapter 6 Controlling Software(LA-PC20)....................................................... 25
6-1. About Controlling Software(LA-PC20) ................................................................25
6-2. Preparation and Startup..........................................................................................25
6-3. Find and Connect the LANIO ...............................................................................25
6-4. Operation................................................................................................................27
Chapter 7 About Input Extension Function without a PC .........................28
7-1. About Input Extension Function............................................................................28
7-2. Rotary Switch ........................................................................................................29
7-3. One to One Connection..........................................................................................29
7-4. One to Multiple Connection ..................................................................................32
7-5. Spontaneous notication function to PC ...............................................................37

3
Chapter 8 Other Functions................................................................................. 38
8-1. Email Alert Function..............................................................................................38
8-2. Pulse Count Function.............................................................................................40
8-3. Auto ON/OFF Control Function............................................................................40
Chapter 9 Input/Output Controlling Commands ............................................... 41
9-1. Controlling Commands..........................................................................................41
9-2. Controlling Commands for Input/Output Model ..................................................41
9-2-1. Conrming Commands for ID number and Input Status ..................................41
9-2-2. Output Controlling Commands ..........................................................................42
9-3. Commands for input extension / spontaneous notication function.....................44
Chapter 10 Library for Input/Output Function .................................................. 46
Chapter 11 Warranty and After Sale Service .....................................................47
11-1. Trouble Shooting..................................................................................................47
11-2. Warranty and Repair.............................................................................................48
11-3. After-Sales Service...............................................................................................49
11-4. Options .................................................................................................................49
Chapter 12 Additional Information.................................................................... 50
12-1. Connect one LANIO and one PC (1 by 1 connection) .......................................50
12-2. Factory Setting .....................................................................................................51
12-3. Factory Setting .....................................................................................................52
12-4. Hardware Block ..................................................................................................54

4
LINEEYE has developed and manufactured this product for purpose of using with
electrical devices such as a computer, a personal device, a measurement device,
semiconductor manufacturing equipment, a vending machine, a sequencer, display
equipment and so on. LINEEYE does not manufacture this product under the
purpose of using with equipment, which may cause malfunction to do harm to the
human body: control equipment for nuclear, aircraft equipment, life maintenance
equipment, traffic signals, etc. Therefore, LINEEYE makes no guarantee with
the mentioned-above use. If you use this product for the purposes mentioned
above, please contact LINEEYE considering safety like Fail Safe under your
responsibilities.
Do not wire or mount when the unit is powered. It leads to electric shock or failure.
When you use the LANIO to the conditions in which an external factor such as cable break, power
failure, and a failure of LANIO leads to a serious incident, exteriorly set a safety circuit such as
inter-lock or emergency stop circuit. An irregular action of the system leads to serious incident such
as system runaway, re, fall, or electric shock.
When wiring, rmly screw the terminal by specied torque 0.5 – 0.6 Nm. If these screws are not
stable, the wires will be disconnected and the contact resistance turns to be greater. It will lead to
heat, re, electric shock, or failure.
Insert a protective fuse and breaker on the load-side in preparation for a short circuit to occur on
output. When a short circuit occurs on the load, it will lead to re, electric shock, or failure.
Use the attached power cable or cable indicated by LINEEYE when power the unit from DC source.
Otherwise a heat, re, electric shock, or injury will cause.
Use the AC adapter indicated by LINEEYE when power the unit from AC source. Otherwise a heat,
re, electric shock, or brake will cause.
Do not apply a voltage not within the specication to the power connector or terminal block. It
leads to heat, re, electric shock, injury, or failure.
Do not disassemble or alter the LANIO or the AC adapter. It leads to heat, re, electric shock,
injury, or failure.
*“Injury” indicates injury, burn, an electric shock, or the like which does not
require hospitalization or the extended hospital visit. “Material damage” indicates
damage related to a house, a building, furniture, apparatus, livestock or a pet.
Danger Level
Be sure to read the following !!
Safety Information
There is a possibility of getting a serious injury or a death if the
device is not used properly.
There is a possibility of getting an injury or material damage if the
device is not used properly.

5
Do not mount on an unstable place or where shake happens. It may fall and leads to injury or
failure.
Do not mount on a place where thermal condition is over the specication or where sudden
temperature change occurs. High temperature or condensation leads to failure.
Do not mount on a place where exposed to direct sunshine. The body temperature over 50℃ leads
to re or failure.
Do not short the pins of the connector. It leads to failure or injury.
Do not use the AC adapter for the models other than specied ones. It leads to heat, re, or injury.
Pull out the AC adapter from an outlet by holding the body. Otherwise the code breaks and it leads
to re or electric shock.
Do not put the code of AC adapter close to a heat. The covering of code melts and it leads to re or
electric shock.
When the unit emits smoke, unusual odor, or unusual sound, stop using immediately. Continuous
usage in this case leads to burn injury, re, or electric shock.
Do not wet the unit. It leads to heat, electric shock, or failure.
Do not insert a metallic fragment or a dust of conducting wire into the unit from an opening section.
It leads to heat, electric shock, or failure.
Do not touch the powered unit or the AC adapter with a wet hand. It leads to electric shock.
Do not use the unit neat inammable gas or corrosive gas exists. It leads to re or failure.
Do not mount or wire the unit where excessive noise exists. It leads to malfunction or failure.
Do not use deteriorated (such as broken) cables. It may heat and cause re.
Do not put many loads on one electrical outlet. It may heat and cause re.

6
Chapter 1 Product Overview
1-1.Overview of LANIO series
LANIO series is a low-cost and compact IO unit with which you can monitor/measure remote signal and
control ON/OFF of the signal via Ethernet LAN. You can remotely control the I/O by sending simple
control commands from a PC to the unit via Ethernet.
Also with some of these models, you can extend an input signal by Ethernet LAN without using PC.
■ Lineup
Each model has dierent numbers of I/O. And, for almost all the models there are standard version and
extended version (G version). The extended version has a LAN device with an extended rmware and supports
TCP multi-session (up to 4 devices) and mail server which needs SMTP-AUTH to send an alert mail.
I/O numbers and contact type Standard model name*1 Extended model name*2
3 relay outputs (1a) and 3 dry contact inputs LA-3R3P-P LA-3R3P-P(G)
5 relay outputs (1a) LA-5R LA-5R(G)
5 dry contact inputs LA-5P-P LA-5P-P(G)
*1 : Stanadard model supports one-on-one TCP connection. Only the mail server which does not need
authentification when connecting is supported. The standard models has XPort-05R (by Lantronix) as its
LAN device.
*2 : The G version (model name ends with G) has xPico (by Lantronix) with extended firmware.
In this manual, we only use standard model name except when describing dierence of the
standard model and extended model.
1-2. Unpacking and Product Composition
Make sure of the following when unpacking the product.
Please let your LINEEYE distributor or LINEEYE know if you nd any damage tothe product caused by
transportation, or if there are accessories lacking.
□LANIO : 1
□Power cable (Model: LAH-15XH) : 1 XH connector cable 1.5m length
□Utility CD-ROM : 1 Setting tool, sample software, and manual PDF
□Instruction Manual : 1 This document
□Warranty : 1

7
1-3. Panel Explanation
The shape and arrangement of the terminal block, connector, and switches are same in all the models. The
number of I/O LED diers depending on the model.
No. Name Explanation Note
1. Detachable I/O terminal block 5.08mm pitch, 10 terminals *1
2. Power jack DC-IN1 AC adapter jack (non-polar) → 2-2.
3. Power jack DC-IN2 XH connector (non-polar) → 2-2.
4. Reset switch reset the unit by pushing this switch *2
5. Rotary switch set an ID number of the unit → 7-3.
6. LAN connector (RJ45) connector for 10/100Base-TX LAN → 2-3.
7. 10/100Base-TX link LED
Left LED Right LED Meaning
No light not connected (no link)
Amber Connected by 10Base-T
Green Connected by 100Base-
TX
No light No communication
Amber Communicating in half-
duplex
Green Communicating in full-
duplex
*3
8. power LED Lights in green when powering *4
9. I/O status LED Lights in red when I/O is ON *5
10. MAC address seal A hardware (MAC) address of the unit
*1 : When you remove the terminal, pull off the terminal directly to the arrow direction. Please do not twist it.
*2 : By resetting the unit, the unit returns to the state when the power is turned on. If the unit is connected with
LAN, the link will be disconnected and all the output status of the unit will be OFF.
*3 : The LED lights in amber for both full-duplex and half-duplex communication for G version.
*4 : The LED of G version and LA-3R3P-P changes the lighting to amber when TCP connection is established.
*5 : Number of LEDs are different in each model.

8
1-4. Common Specication
■ External Dimension : 74 x 106 x 30 mm ( W x D x H ) Weight : About 280g
■ LAN Interface
LAN Interface RJ45 Connector 10Base-T/100Base-TX auto-detection Ethernet : IEEE
802.3
LAN Protocol *1 TCP/IP, UDP/IP, ARP, ICMP, SNMP, TFTP, Telnet, DHCP, BOOTP, HTTP,
AutoIP, SMTP
Insulated Transformer 1500V
*1 : Other protocols than TCP/IP, UDP/IP are not available from a user application.
■ General Specication
Power DC8 - 30V non-polar *1
Power Consumption Max 3 W
Operating Temperature and
Humidity
-20 - +55℃ , 10 - 95%RH (No condensation)
Storage Temperature and
Humidity
-25 - +75℃, 10 - 95%RH (No condensation)
Vibration Resistant
10 - 60 - 150Hz 50m/s2, Amplitude of vibration 0.35mm, for each
direction X,Y,Z, Sweep 20 cycles, Conformed to JIS C60068-2-6 (JIS
C0040)
Shock Resistant 500m/s2, Period of time 11ms, Sine half wave pulse for each direction
X,Y,Z for 3 times, Conformed to JIS C60068-2-27 (JIS C0041)
Noise Resistant ±1500Vp-p by noise simulator, width 1μS/50nS, Normal/Common
mode
Voltage Resistant AC2000V for 1 munite For between relay output terminalsin lump,
input terminals in lump, the body, and the power source
Insulation Resistance
50 MΩ or more by DC500V mega For between I/O terminals in
lump,the body, and the power source
For Output terminals in lump and Input terminals in lump
Usage Atmosphere No ammable gas or corrosive gas
Not much dust (especially conductive one)
*1 : DC-IN1 matches with an optional AC adapter (6A-181WP09).
DC-IN2 matches with an attached power cable or optional power branch cable (LAH-2XH).
→ “2-2. Power supply”

9
Chapter 2 Setup and Installation
2-1. Installation
■ Stationary Installation
Install the unit on the at and stable place.
■ Screwing the unit to a board such as a control panel
Use four M3 screw halls on the back side of the unit when you attach the unit to a board such as a control panel
by screwing it.
[ The position of M3 screw halls on the back side ] [ An example gure of screw hall planning on a panel ]
・Do not use a screw which can be inserted into the unit more than 4mm depth from the top of the case. For
example, when you attach the unit to a panel of 1mm thickness use M3 screw of less than 6mm length.
・When the rubber legs impede the attachment of a panel, remove the rubber legs and screw it.
■ Attachment to a DIN rail
You can attach the unit to a 35mm DIN rail by using SI-DIN70 (optional). Also you can use a optional vertical
mounting plate (SI-DIN30).
1. Screw DIN rail mounting plate (SI-DIN70) to four M3 screw
halls on the bottom of the product with the knob of SI-DIN70
to the direction of LAN connector side.
2. Insert it by pushing it into the DIN rail from the front side of
the rail. To insert it, tilt it a little bit and put the non-knob side
into the rail first. Then put the knob side into the rail until a
click sounds.
3. To remove the plate from the DIN rail, pull up the knob using
the screwdriver etc. and remove the unit from the DIN rail.
・Before screwing the unit or mounting the unit to a DIN rail, make sure to disconnect power
source from the unit.
・When placing the unit, make sure not to put it near a high-voltage instrument or an electric
power equipment.
DIN rail mounting plate
(SI-DIN70) [ Option ]
→ “20-5. Option”
This manual suits for next models
3
Table of contents
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions