LG Multi V User manual

INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
P/NO : MFL67798106
www.lg.com
TYPE: Wall Mounted
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ

2Indoor Unit
Wall Mounted Type Indoor Unit Installation Manual
TABLE OF CONTENTS
❏ Installation guide map
❏Four type "A" screws & plastic
anchors
❏Connecting cable
❏Pipes: Gas side
Liquid side
(Refer to Product
Data)
❏Insulation materials
❏Additional drain pipe
❏Two type "B" screws
❏Level gauge
❏Screw driver
❏Electric drill
❏Hole core drill
❏Horizontal meter
❏Flaring tool set
❏Specified torque wrenches
(different depending on model No.)
❏Spanner .......Half union
❏A glass of water
❏Screw driver
❏Hexagonal wrench
❏Gas-leak detector
❏Vacuum pump
❏Gauge manifold
❏Owner's manual
❏Thermometer
❏Holder Remote Controller
Installation Parts ....................3
Safety Precautions.................4
Installation
Selection the best location ....7
Piping Method........................8
Drain Piping .........................13
Wiring Connection ...............13
Installation of wirelss
remote controller..................15
Installation of Wired Remote
Controller..............................16
Name and function of wired
remote controller(Accessory)
..............................................18
Installer Setting -How to enter
installer setting mode...........19
Group Control Setting..........20
Installation Requirements Required Parts Required Tools

Installation Parts
ENGLISH
Installation Manual 3
Installation Parts
Name
Quantity
Shape
Installation panel
1 set
Type "A" screw
SE: 6 EA
S5: 8 EA
(Other)
• Owner's manual
• Installation manual
Standard Accessories
SE
S5
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
5feet
(1.5meters)
no
no
no
yes
RemoteController
TEMP
RemoteController
TEMP
RemoteController
TEMP

Safety Precautions
4Indoor Unit
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
■Be sure to read before installing the air conditioner.
■Be sure to observe the cautions specified here as they include important items related to safety.
■Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the
following indications.
■Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
■Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a dedi-
cated circuit.
• There is risk of fire or electric
shock.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• Do not disassemble or repair
the product. There is risk of
fire or electric shock.
Always ground the product.
• There is risk of fire or electric
shock.
Install the panel and the
cover of control box securely.
• There is risk of fire or electric
shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or installation
may cause fire or electric
shock.
Use the correctly rated break-
er or fuse.
• There is risk of fire or electric
shock.

Safety Precautions
ENGLISH
Installation Manual 5
■Operation
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
Do not let the air conditioner
run for a long time when the
humidity is very high and a
door or a window is left open.
• Moisture may condense and
wet or damage furniture.
Be cautious when unpacking
and installing the product.
• Sharp edges could cause
injury. Be especially careful of
the case edges and the fins
on the condenser and evapo-
rator.
For installation, always con-
tact the dealer or an Autho-
rized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the product on
a defective installation stand.
• It may cause injury, accident,
or damage to the product.
Be sure the installation area
does not deteriorate with age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress
air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion.
• There is the risk of death, injury, fire or explosion.

Safety Precautions
6Indoor Unit
■Installation
Always check for gas (refrig-
erant) leakage after installa-
tion or repair of product.
• Low refrigerant levels may
cause failure of product.
Install the drain hose to
ensure that water is drained
away properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
Do not install the product
where the noise or hot air from
the outdoor unit could dam-
age the neighborhoods.
• It may cause a problem for
your neighbors.
Use two or more people to lift
and transport the product.
• Avoid personal injury.
Do not install the product
where it will be exposed to
sea wind (salt spray) directly.
• It may cause corrosion on the
product. Corrosion, particularly
on the condenser and evapora-
tor fins, could cause product
malfunction or inefficient opera-
tion.
If you eat the liquid from the
batteries, brush your teeth and
see doctor. Do not use the
remote if the batteries have
leaked.
• The chemicals in batteries
could cause burns or other
health hazards.

Installation
ENGLISH
Installation Manual 7
Read completely, then follow step by step.
Installation
Selection of the best location
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
The mounting wall should be strong and solid
enough to protect it from the vibration.
Front
Right Rear right
Rear left
Down right
Left
Lower than 2.3m
More than 200 mm
Higher than eye-level
More than
100 mm
More than
100 mm
Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the loca-
tion of the installation plate-routing of the wiring to
power outlets is through the walls typically. Drilling
the hole through the wall for piping connections
must be done safely.
Chassis
Hook
Installation Plate
Type “A”
Chassis
Hook
Installation Plate
Type “A”
Installation plate
Left rear piping Right rear piping
Ø70mm Ø70mm
DB
A
C
Installation plate
Left rear piping Right rear piping
Ø70mm 133mm Ø70mm
100mm
<S5>
<SE>
<S5>
<SE>
ABCD
SE 70 110 90 110
S5 100 122 240 122
CHASSIS
Distance (mm)

Installation
8Indoor Unit
Piping Method
CAUTION : When
install, make sure that
the remaining parts must be
removed clearly so as not to
damage the piping and drain
hose, especially power cord
and connecting cable.
■Preparing the indoor unit's piping and drain hose for
installation through the wall.
■Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
■Replace the plastic tubing holder in the original position.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
■Do not connect the cable to the indoor unit.
■Make a small loop with the cable for easy connection
later.
■Drill a hole in the wall
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
3. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.
: If the drain hose is routed inside the room,
insulate the hose with an insulation material* so that drip-
ping from "sweating"(condensation) will not damage furni-
ture or floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
■Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
5. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
■Align the center of the pipings and sufficiently tighten
the flare nut by hand.
NOTICE
For left rear piping
To remove the holder,
press the bottom of
chassis near the holder
upward and pull the tab
out of its hole.
Tubing holder
Pull
Press
2
1
Drain hose
Connecting
cable
Loop
Gas side
piping
Liquid side
piping
Drain hose
Drain hose
Connecting
cable
Indoor unit tubing Flare nut Pipings
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor

Installation
ENGLISH
Installation Manual 9
■Tighten the flare nut with a wrench.
■When extending the drain hose at the indoor unit,
install the drain pipe.
6. Wrap the insulation material around the connect-
ing portion.
■Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
■Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
■Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec-
tion.
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose and the connecting
cable into the piping hole.
GAS LIQUID
Ø12.7[5.5kgf.m] Ø6.35[1.8kgf.m]
Ø15.88[6.6kgf.m] Ø9.52[4.2kgf.m]
Pipe Size[Torque]
For right rear piping
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor
unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Drain pipe
Connecting cable
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit
drain hose
Plastic bands Insulation material
If the split type Indoor unit is installed in a wall hav-
ing hole or opening near by or back side of the unit,
then the air from other side of the wall can come
inside the condition space through that hole/ open-
ing. That air can cause unwanted dew/ water
droplet formation when it comes in contact with
body of the indoor unit. So all hole or opening on
the wall must be blocked very well to avoid water
dropping from the body of the unit.

Installation
10 Indoor Unit
3. Insert the connecting cable into the indoor unit.
■Don't connect the cable to the indoor unit.
■Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cable.
• Connecting cable
5. Indoor unit installation
■Hang the indoor unit from the hooks at the top of
the installation plate.
■Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
6. Connecting the pipings to the indoor unit and
the drain hose to drain pipe.
■Align the center of the pipings and sufficiently
tighten the flare nut by hand.
■Tighten the flare nut with a wrench.
■When extending the drain hose at the indoor unit,
install the drain pipe.
7. Wrap the insulation material around the connect-
ing portion.
■Overlap the connection pipe heat insulation and
the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no
gap.
■Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
Plastic bands Insulation material
Vinyl tape
(narrow)
Connection
pipe
Connecting
cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Installation plate
Spacer
Indoor unit
8cm
Indoor unit tubing Flare nut Pipings
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
GAS LIQUID
Ø12.7[5.5kgf.m] Ø6.35[1.8kgf.m]
Ø15.88[6.6kgf.m] Ø9.52[4.2kgf.m]
Pipe Size[Torque]
Other manuals for Multi V
13
This manual suits for next models
1
Table of contents
Other LG Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual