Koolance ALX Series User manual

Superior Liquid Cooling Systems
®
English v1.0
ALX Series Products
User’s Manual
ALX Series Products
User’s Manual

A newer version of this User Manual may exist. Please be sure to check our support page
for the latest version of this guide: www.koolance.com
GENERAL PRECAUTION
Please read this manual carefully before beginning the installation of your Koolance
system.
PROHIBITED USE
This product is designed, developed and manufactured as contemplated for general use,
designed, developed and manufactured as contemplated for use accompanying fatal risks or
dangers that, unless extremely high safety is secured, could lead directly to death, personal
injury, severe physical damage or other loss, including without limitation: nuclear power core
or weapon launching control. If these products are used in such hazardous environments,
Koolance Incorporated does not warrant them.
TRADEMARKS
The Koolance name and logo are trademarks or registered trademarks of Koolance, Inc.
only and may be trademarks or registered trademarks of their respective companies.
COPYRIGHT
All rights reserved. Copyright (C) Koolance Incorporated.
!WARNING:Indicates a potentially hazardous situation which, if not avoided,
could result in personal injury or be life-threatening.
!CAUTION:Indicates a potentially hazardous situation which, if not avoided,
may result in damage to equipment or property.
PROHIBITED:Indicates a prohibited action.
ABOUT SIGNS
Throughout this document, critical information is highlighted in gray-colored boxes. The
following symbols are intended to help prevent any situation which may cause personal
injury and/or damage to equipment:
1
Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Table of Contents
Product Diagram ............................................................................................. 3
Positioning the System ................................................................................... 4
Combining Modules ........................................................................................ 4
Wiring.............................................................................................................. 6
Tube Fittings ................................................................................................... 7
Coolant Filling and Powering-On .................................................................... 8
Display Panel .................................................................................................. 9
Temp Set....................................................................................................... 10
Alarm Set ...................................................................................................... 10
Relay Set ...................................................................................................... 11
Pump Set ...................................................................................................... 11
Display Set.................................................................................................... 11
Software Feature .......................................................................................... 12
Troubleshooting ............................................................................................ 13
WARNING: The Koolance liquid coolant contains chemicals which may
be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS
CHEMICALS OUT OF THE REACH OF CHILDREN. Please refer to
the coolant MSDS available on our website: www.koolance.com
!
CAUTION: Supply only the proper input voltage and polarity to the
cooling system, as labeled below the terminals on the unit. Improper
power can damage the unit and is not covered under the warranty.
!
KOOLANCE CONTACT INFORMATION
Koolance Inc. (USA)
Address: 2840 W. Valley Hwy. N., Ste. 101, Auburn, WA 98001, USA
Telephone: +01 253-249-7669
2

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Product Diagram
Radiator Fans
Display
Panel
Power Terminals
Reservoir Fill Port
ALX systems are composed of two modules physically connected together: the
front “RPM” and rear “HXM”. Diagrams below are general representations, as
RPM Reservoir and Pump Module
Coolant Reservoir
Control Buttons
Main Power
Switch
HXM Heat Exchanger Module
Radiator
(Internal)
3

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Positioning the System
Combining Modules
If you have purchased both RPM and HXM modules, they are combined together
using hardware included with those products.
This product must be operated in an upright orientation (shown below). Alternative
orientations can prevent the coolant pump from operating properly.
RPM module onto its rear inlet and outlet.
is a parallel thread, do not use plumber’s
tape.)
the HXM module onto its *front* inlet and
(This is a parallel thread, do not use
plumber’s tape.)
Fittings on Rear of RPM
Fittings on Front of HXM
4

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Fasten the included mounting
bracket to the rear of the RPM
module using four bracket
screws.
The bracket must match the
orientation shown to the right.
Finish combining modules by securing
the bracket with its remaining four
screws.
Two screws are installed into
corresponding holes on each side of
the HXM module.
5

There are several available wire terminals near
the reservoir window of the RPM module:
1. Two K-Type Thermocouples (not included)
2. Relay Output NO/NC (normally open or closed)
3. USB for Data Logging (Type B Plug)
4. HXM Module, Fan & Flow Meter ribbon cable
5. Connect power leads to the red positive “+” and
black negative “-” power terminals, as labeled on
the side of the unit.
Connect the included ribbon cable
between RPM and HXM “HX Module”
plugs. For the data logging feature,
attach the included USB cable.
There is a cable guide beneath the
reservoir to hide some of the wiring.
The ALX cooling system requires a 12VDC power supply (not included). Amperage
for RPM and HXM modules are printed separately on their labels. These can be
added together for the total power requirement and range between 2-8A.
CAUTION: Supply only the proper input voltage and polarity to the
cooling system, as labeled below the terminals on the unit. Improper
power can damage the unit and is not covered under the warranty.
!
Wiring
1
2
3
4
5
For a cleaner appearance, the power and
USB cables can be routed beneath the
HXM module towards the back.
Zip ties are included to secure them to the
radiator grill (use needle-nose pliers).
6
Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Cut tubing into two segments. You
will need to connect each to the rear
Each tubing connection will use a threaded compression
ring or tube clamp to keep it secure. Be sure to thread
the compression ring or tube clamp onto the tubing
before attaching it.
dipping the end of the tubing in water.
Tighten the connection by sliding the compression
into the proper position before releasing.
tapered 1/4-inch NPT. Plumber’s tape (PTFE) is required to
seal them properly.
Tube Fittings
After wrapping with tape, the inlet and
outlet fittings should be inserted by
the last 1-2 rotations.
7

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
Power on the cooling unit, and increase the pump speed to move coolant if
needed. When most of the air has been pushed out of the tubing, the liquid
noise will decrease. This process can take several minutes, depending
During this process, liquid components (or the cooling system itself) may need to
be tilted gently to assist with air evacuation. The reservoir level will decrease during
To
maintain the product warranty, use
only Koolance approved coolant.
Many alternative liquids and additives
can cause permanent damage to the
cooling unit (through chemical reaction,
corrosion, biological growth, high thermal
expansion, viscosity, etc.).
port.
etc.) have been connected with tubing,
the large slot-headed screw with a screwdriver or
large coin.
Coolant Filling and Power-On
WARNING:Most coolants are electrically conductive. Use caution
and power cables. Keep the primary AC supply unplugged whenever
!
Never
An air gap must always remain to ac-
commodate thermal expansion of the liquid.
8

Arbel Agencies LTD.
11 Ba’alei Hamelacha st. Qiryat Bialik P.O.B 1095, ZIP 2751311, ISRAEL
+972(0)48736969 +972(0)48730708 www.arbel-ltd.com
• On the main screen, hold ◙for 3 seconds to change display units between
°C/°F and LPM/GPM.
• You can exit any menu and return to the main screen by holding ◙for 2
seconds.
• To reset ALL settings to default, hold ▼ + ▲ for 3 seconds.
Main Menu
◙
Use ▼ and ▲ to navigate this menu.
TEMP/FAN SET : Temperature set-point adjustment
ALARM SET : Alarm settings
RELAY SET : Relay Trigger settings
PUMP SET : Pump speed settings
DISPLAY SET : LED display settings
When in the top menu, press ◙to enter one of the above categories. To exit from
here, press ◄.
External Sensors
This unit has an integrated liquid temperature
sensor in the reservoir. It also provides terminals
for connecting up to two K-type thermocouples (not
included) for external temperature monitoring and
set point options.
Display Panel
The Koolance display panel allows control and monitoring of various aspects of
the cooling unit. 5 buttons are used, with directional arrows to navigate or change
settings, and a center button to select/exit.
Navigate Up,
Increase Setting
Navigate Down,
Decrease Setting
Navigate
Left
Navigate
Right
Enter/Exit
◙
▲
▼
9
Other manuals for ALX Series
1
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual