Keysight 42942A Operation manual

Operation and
Service Manual
Keysight 42942A Terminal Adapter,
40 Hz to 110 MHz

Notices
© Keysight Technologies
1999 - 2019
No part of this manual may be repro-
duced in any form or by any means
(including electronic storage and
retrieval or translation into a foreign
language) without prior agreement
and written consent from Keysight
Technologies, Inc. as governed by
United States and international
copyright laws.
Manual Part Number
42942-90020
Edition
Edition 6, August 21, 2019
Printed in Malaysia
Published by:
Keysight Technologies International
Japan G.K,
1-3-3 Higashikawasaki-cho
Chuo-ku
Kobe-shi, Hyogo, Japan
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO
THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES,
EITHER EXPRESS OR IMPLIED WITH
REGARD TO THIS MANUAL AND
ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT LIM-
ITED TO THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PUR-
POSE. KEYSIGHT SHALL NOT BE
LIABLE FOR ERRORS OR FOR INCI-
DENTAL OR CONSEQUENTIAL DAM-
AGES IN CONNECTION WITH THE
FURNISHING, USE, OR PERFOR-
MANCE OF THIS DOCUMENT OR
ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND
THE USER HAVE A SEPARATE WRIT-
TEN AGREEMENT WITH WARRANTY
TERMS COVERING THE MATERIAL
IN THIS DOCUMENT THAT CON-
FLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPA-
RATE AGREEMENT WILL CONTROL.
Technology Licenses
The hardware and/or software
described in this document are fur-
nished under a license and may be
used or copied only in accordance
with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this
product and for other Keysight prod-
ucts may be downloaded from the
Web. Go to http://www.key-
sight.com/go/conformity. You can
then search by product number to
find the latest Declaration of Confor-
mity.
U.S. Government Rights
The Software is “commercial com-
puter software,” as defined by Fed-
eral Acquisition Regulation (“FAR”)
2.101. Pursuant to FAR 12.212 and
27.405-3 and Department of Defense
FAR Supplement (“DFARS”)
227.7202, the U.S. government
acquires commercial computer soft-
ware under the same terms by which
the software is customarily provided
to the public. Accordingly, Keysight
provides the Software to U.S. gov-
ernment customers under its stan-
dard commercial license, which is
embodied in its End User License
Agreement (EULA), a copy of which
can be found at http://www.key-
sight.com/find/sweulaThe license set
forth in the EULA represents the
exclusive authority by which the U.S.
government may use, modify, dis-
tribute, or disclose the Software. The
EULA and the license set forth
therein, does not require or permit,
among other things, that Keysight:
(1) Furnish technical information
related to commercial computer soft-
ware or commercial computer soft-
ware documentation that is not
customarily provided to the public; or
(2) Relinquish to, or otherwise pro-
vide, the government rights in
excess of these rights customarily
provided to the public to use, modify,
reproduce, release, perform, display,
or disclose commercial computer
software or commercial computer
software documentation. No addi-
tional government requirements
beyond those set forth in the EULA
shall apply, except to the extent that
those terms, rights, or licenses are
explicitly required from all providers
of commercial computer software
pursuant to the FAR and the DFARS
and are set forth specifically in writ-
ing elsewhere in the EULA. Keysight
shall be under no obligation to
update, revise or otherwise modify
the Software. With respect to any
technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the
U.S. government acquires no greater
than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as
applicable in any technical data.
Safety Notices
A CAUTION notice denotes a haz-
ard. It calls attention to an oper-
ating procedure, practice, or the
like that, if not correctly per-
formed or adhered to, could
result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION
notice until the indicated condi-
tions are fully understood and
met.
A WARNING notice denotes a haz-
ard. It calls attention to an oper-
ating procedure, practice, or the
like that, if not correctly per-
formed or adhered to, could
result in personal injury or death.
Do not proceed beyond a WARN-
ING notice until the indicated
conditions are fully understood
and met.

Keysight 42942A Terminal Adapter 3
Contents
1. Installation Guide
Incoming Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Connecting the 42942A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2. Overview
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3. Operation
Impedance Analyzer Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Adapter Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Connecting Test Fixture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Fixture Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Performing Open Compensation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Performing Short Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Performing Load Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Fixture Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
4. Specifications
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
5. Service
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

4 Keysight 42942A Terminal Adapter
Contents

Keysight 42942A Terminal Adapter 5
Installation Guide
Incoming Inspection
1 Installation Guide
Incoming Inspection
Inspect the shipping container for damage. If the shipping container or
cushioning material is damaged, it should be kept until the contents of the
shipment have been checked for completeness and the 42942A has been
checked mechanically and electrically. The shipment should contain
everything listed in Table 1-1. If the contents are incomplete or if there is
mechanical damage or defect, notify the nearest Keysight Technologies office.
If the shipping container is damaged or the cushioning material shows signs of
unusual stress, notify the carrier as well as the Keysight Technologies office.
Keep the shipping materials for the carrier’s inspection.
Table 1-1 Contents
Description Part Number Qty.
42942A Terminal Adapter - 1
OPEN104191-85302 1
SHORT104191-85300 1
LOAD104291-60043 1
Operation and Service Manual Option ABA 1
Carrying Case 42942-60011 1
1. Furnished with Option 700.

6 Keysight 42942A Terminal Adapter
Installation Guide
Connecting the 42942A
Connecting the 42942A
Follow the steps below to connect the 42942A to the Impedance Analyzer.
Step 1. Join the 42942A terminal adapter to the test connectors on the front panel of
the Impedance Analyzer by gently matching the four BNC connectors and
fastening screws of the adapter with the test connectors and accessory
mounting holes of the instrument until they come into complete contact.
Step 2. Turn the adapter’s two fastening screws clockwise at the same time until the
fixture is firmly secured to the instrument.
Figure 1-1 Connecting 42942A to Impedance Analyzer

Keysight 42942A Terminal Adapter 7
Installation Guide
Cleaning
Cleaning
Even a tiny amount of dirt on the 7-mm connector of the OUTPUT port would
greatly degrade the accuracy of your measurement. Use a lint-free cloth to
clean the connector if it gets dirty.
Serial Number
Keysight Technologies uses a ten-character serial number that is stamped on
the serial number plate attached to the bottom of the four-terminal pair
connection block. The first two characters shows the made-in country, the next
three digits are assigned as the serial prefix, and the last five digits are the
suffix.

8 Keysight 42942A Terminal Adapter
Installation Guide
Serial Number

Keysight 42942A Terminal Adapter 9
Overview
Product Overview
2 Overview
Product Overview
The 42942A is an adapter equipped with a 7-mm coaxial connector that
connects a test fixture furnished with the same type of connector to the
Impedance Analyzer.
Figure 2-1 Product Overview

10 Keysight 42942A Terminal Adapter
Overview
Functions
Functions
Figure 2-2 and Figure 2-3 show the names of the 42942A’s parts and contents
of the option 700, respectively.
Figure 2-2 42942A Parts
Table 2-1 42942A Function
No. NAME FUNCTION
1 OUTPUT Port Contact for the test fixture furnished with a 7-mm
coaxial connector.
2 Mounting Post Guide and support post for fixture connection.
3 Adapter Fastening
Screws
Secures the fixture to the Impedance Analyzer.
Table of contents
Other Keysight Adapter manuals

Keysight
Keysight 11878A Service manual

Keysight
Keysight P281B Service manual

Keysight
Keysight U1117A User manual

Keysight
Keysight N4865A User manual

Keysight
Keysight U1177A User manual

Keysight
Keysight 86205A Service manual

Keysight
Keysight R281A Quick start guide

Keysight
Keysight N5192A UXG X-Series Owner's manual

Keysight
Keysight U1586B User manual

Keysight
Keysight N7010A User manual




















