Kaden KCI36 User manual

Installation
Manual
CASSETTE AIR CONDITIONER
KCI Series
KCI36 | KCI42 | KCI48

Important note
This appliance must be installed in accordance with:
Manufacturer’s Installation Instructions
Current AS/NZS 3000, AS/NZS 5149
Local Regulations and Municipal Building Codes including
local OH&S requirements
This appliance must be installed, maintained, and removed
only by an Authorised Person.
For continued safety of this appliance, it must be installed
and maintained in accordance with the manufacturer’s
Instructions.
REFRIGERANT
R32

Kaden Installation Manual | 3
1. Safety precautions 4
2. Accessories 7
3. Installation summary 8
Unit Parts 9
4. Indoor unit installation 10
Installation instructions – Indoor unit 10
Note for new home installation 13
Note on purchasing pipes 13
Note on drainpipe installation 14
5. Outdoor unit installation 15
Installation instructions – Outdoor unit 15
Special considerations for extreme weather 15
6. Refrigerant piping connection 18
Note on pipe length 18
Connection instructions – Refrigerant piping 19
Note on minimum bend radius 21
7. Wiring 22
Note on isolator 22
Outdoor unit wiring 23
Indoor unit wiring 24
Power specifications 25
8. Leak testing and evacuation 26
Leak, pressure test and evacuation 26
Preparations and precautions 27
Opening outdoor unit valves 27
Note on adding refrigerant 27
9. Panel installation 28
10. Test run 30
Before test run 30
Test run instructions 30
11. Error codes 31
Table of contents
Important note
Read this manual carefully before installing
or operating your new air conditioning unit.
Make sure to save this manual for future reference.

4 | Kaden Installation Manual
1. Safety precautions
Read safety precautions before operation and installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
WARNINGS FOR PRODUCT USE
This symbol indicates the possibility of property damage or serious consequences.
This symbol indicates the possibility of personal injury or loss of life.
Do not share the electrical outlet with other appliances.
Improper or insufficient power supply can cause fire or
electrical shock.
When connecting refrigerant piping, do not let
substances or gases other than the specified refrigerant
enter the unit. The presence of other gases or
substances will lower the unit’s capacity, and can cause
abnormally high pressure in the refrigeration cycle.
This can cause explosion and injury.
Do not allow children to play with the air conditioner.
Children must be supervised around the unit at all times.
1. Installation must be performed by a licensed installer.
Defective installation can cause water leakage, electrical
shock, or fire.
2. Installation must be performed according to the
installation instructions. Improper installation can cause
water leakage, electrical shock, or fire.
3. Contact an authorised service technician for repair or
maintenance of this unit.
4. Only use the included accessories, parts, and specified
parts for installation. Using non-standard parts can cause
water leakage, electrical shock, fire, and can cause the
unit to fail.
5. Install the unit in a firm location that can support the unit’s
weight. If the chosen location cannot support the unit’s
weight, or the installation is not done properly, the unit
may drop and cause serious injury and damage.
6. Only fully qualified licensed personnel should install
service or carry out maintenance to this air conditioning
unit. All electrical work is to follow local and national
wiring standards and the Installation Manual.
7. You must use an independent circuit and single outlet to
supply power. Do not connect other appliances to the
same outlet. Insufficient electrical capacity or defects in
electrical work can cause electrical shock or fire.
8. For all electrical work, use the specified cables. Connect
cables tightly, and clamp them securely to prevent
external forces from damaging the terminal. Improper
electrical connections can overheat and cause fire, and
may also cause shock.
9. All wiring must be properly arranged to ensure that
the control board cover can close properly. If the
control board cover is not closed properly, it can lead
to corrosion and cause the connection points on the
terminal to heat up, catch fire, or cause electrical shock.
10. In certain functional environments, such as kitchens,
server rooms, etc., the use of specially designed air-
conditioning units is highly recommended.
11. This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children must not
play with the appliance. Cleaning and user maintenance
must not be made by children without supervision.

Kaden Installation Manual | 5
CAUTION
Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around
the unit, it may cause fire.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can
cause electrical components to short circuit.
1. The product must be properly grounded at the time of installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your
home and property.
Note about fluorinated gases
1. This air-conditioning unit contains fluorinated gases. For specific information on the type of gas and the amount, please
refer to the relevant label on the unit itself.
2. Installation, decommissioning, service, maintenance and repair of this unit must be performed by a licensed technician.
3. Product decommissioning and recycling must be performed by a licensed technician.
4. If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months.
5. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
6. Only ARC (Australian Refrigeration Council) licence holders can install and commission this air conditioner. This air
conditioner must be installed to meet the requirements of the current version of AS/NZS 5149. It is illegal to vent some
types of refrigerant to the atmosphere.
REFRIGERANT
This appliance uses R32 (difluoromethane) refrigerant, which is a flammable gas class 2.2 according to AS/NZS 5149 and must
be handled by a refrigeration mechanic with appropriate Australian refrigerant handling licence.
• WARNING risk of fire/flammable material. If the refrigerant is leaked, together with an external ignition source, there is
possibility of ignition.
• Read all the OPERATING INSTRUCTIONS carefully before operation.
• Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL
before operation.
• Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL and the like.
Certain levels of refrigerant require minimum room sizes. Please ensure that these minimum room sizes are adhered to for
standard installations (up to 10m pipe length). If larger refrigerant charges than standard are used then please consult AS/NZS
60335.2.40 to determine the safe minimum floor area for the installation.
Make sure that the area has been made safe by having suitable ventilation and is free from ignition sources before charging or
recovering the charge of R32.

6 | Kaden Installation Manual

Kaden Installation Manual | 7
2. Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air
conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail.
Name of accessories Qty (pc) Shape Name of accessories Qty (pc) Shape
Owners, Installation
& Remote Controller
Manuals
3Drain joint 1
Soundproof/insulation
sheath 1Seal ring 1
Soundproof/insulation
sheath 1Copper nut 2
Outlet pipe sheath 1
Magnetic ring – wrap the
electric wires S1 & S2
around the magnetic
ring twice
1
Drain outlet pipe 1
Magnetic ring – hitch it
on the connective cable
between indoor unit
and outdoor unit after
installation
Varies by
model
Ceiling hook 4
Suspension bolt 4
Wired Controller 1

8 | Kaden Installation Manual
3. Installation summary
Install the indoor unit Install the drainpipe Install the outdoor unit
Pressure test and evacuation
Connect the power wires Connect the refrigerant pipes
Install the front panel Perform a test run
1
78
2
5
9
3
4
Connect the signal wires
6
S1 S2 L N

Kaden Installation Manual | 9
Unit parts
NOTE: The installation must be performed in accordance with Australian guidelines.
The installation may be slightly different in different areas.
Note on illustrations
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different.
1 Air outlet
2 Air inlet
3 Front grille
4 Display panel
5 Remote controller/
wired controller
6 Drain pipe
7 Connecting pipe
8 Air inlet
9 Air outlet
1
2
4
36
7
9
5
9
8

10 | Kaden Installation Manual
4. Indoor unit installation
Installation instructions – Indoor unit
NOTE: Panel installation should be performed after piping and wiring have been completed.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location. The following are standards that will help you choose an
appropriate location for the unit.
Proper installation locations meet the following standards:
✓Enough room exists for installation and maintenance.
✓Enough room exists for the connecting pipe and drainpipe.
✓The ceiling is horizontal and its structure can sustain the
weight of the indoor unit.
✓The air inlet and outlet are not blocked.
✓The airflow can fill the entire room.
✓There is no direct radiation from heaters.
DO NOT install unit in the following locations:
✕Areas with oil drilling or fracking
✕Coastal areas with high salt content in the air
✕Areas with caustic gases in the air, such as hot springs
✕Areas that experience power fluctuations, such as factories
✕Enclosed spaces, such as cabinets
✕Kitchens that use natural gas
✕Areas with strong electromagnetic waves
✕Areas that store flammable materials or gas
✕Rooms with high humidity, such as bathrooms
or laundry rooms
Recommended distances between the indoor unit and the ceiling
The distance between the mounted indoor unit and the internal ceiling should meet the following specifications.
Distance from ceiling relative to height of indoor unit
Type Model A (mm) H (mm) B (mm)
KCI880
KCI36 287 >317
KCI42
KCI48 287 >317
Ceiling
Ceiling board
>2500mm
Front panel
Ground
A
B (Ceiling hole)
287 >317
This manual suits for next models
3
Table of contents
Other Kaden Air Conditioner manuals

Kaden
Kaden KDI42 User manual

Kaden
Kaden KSI Series User manual

Kaden
Kaden KCS Series User manual

Kaden
Kaden KSI Series User manual

Kaden
Kaden KCI Series User manual

Kaden
Kaden KSI R32 User manual

Kaden
Kaden KC17 User manual

Kaden
Kaden KD Series User manual

Kaden
Kaden KDI36 User manual

Kaden
Kaden KS09 User manual
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual