Jumper PD-FR409-B User manual

JPD-FR409-BT
Infrared Thermometer
Instruction Manual
Shenzhen Jumper Medical Equipment Co., Ltd
Manual Version: 1.0
Date of Issue: 2019.8
0482

Product Information
Product Name: Infrared Thermometer
Model: JPD-FR409-BT
Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd
Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan,
Shenzhen, Guangdong, China.
Copyright
Copyright © Jumper Medical.
All rights reserved.
Statement
Shenzhen Jumper Medical Equipment Co., Ltd. owns and reserves all of
the rights comprised in the copyright of this document. No part of this
document may be changed, excerpted, copied, reproduced, or imitated in
any form or by any means without the prior consent of Shenzhen Jumper
Medical Equipment Co., Ltd.
All statements, information, and recommendations in this document are
provided "AS IS" without warranties, guarantees or representations of any
kind, either express or implied. The information in this document is
subject to change without notice. Shenzhen Jumper Medical Equipment
Co., Ltd. reserves the right of final interpretation of this document.
Introduction
Thank you for purchasing this Infrared Thermometer. Please read the User
Manual carefully to make sure safe and proper use of this thermometer.
Please read and fully understand the Safety Precautions before use.
Keep the Instruction Manual with this thermometer for future
reference.

Contents
FCC Statement................................................................................................ 1
Unpacking Check............................................................................................2
Package Contents............................................................................................ 2
Safety Precautions...........................................................................................2
Warning............................................................................................................4
Symbols........................................................................................................... 5
Body Temperature Basics............................................................................... 6
Product Description.........................................................................................8
Features............................................................................................................9
Product structure........................................................................................... 10
Display description....................................................................................... 10
Sounds and indicator color instructions.......................................................11
Display and Operating Instructions..............................................................11
Measuring Ear Temperature......................................................................... 18
Measuring Forehead Temperature................................................................20
Measuring Object Temperature....................................................................21
Connecting the Thermometer to an APP Application of a Mobile Phone.22
Replacing Batteries....................................................................................... 23
Cleaning and Disinfection............................................................................ 24
Maintenance.................................................................................................. 25
Troubleshooting.............................................................................................26
Specifications................................................................................................ 27
Security Class................................................................................................28
Storage and Transportation...........................................................................28
EMC Information-Guidance and Manufacture’s Declaration....................29
Warranty and After-Sale Service..................................................................34

1
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Notes:
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions,may cause harmful interference to radio
communications.However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
■ Reorient or relocate the receiving antenna.
■ Increase the separation between the equipment and receiver.
■ Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
■ Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly
approved by manufacturer could void your authority to operate this
equipment.

2
Unpacking Check
Please open the package carefully before use, check whether all
accessories are available or not and whether any component is damaged
during transportation, and perform installation and operation following this
user manual. In case of any damage or operation problem, please contact
the dealer or contact Jumper directly. You will need the following
information when making your claim:device model, serial number,
purchase date, and your contact information and address.
Package Contents
No.
Name
Quantity
1
Infrared Thermometer
1
2
Pouch
1
3
Battery (AAA)
2
4
Instruction Manual
1
Safety Precautions
Read the following precautions carefully before using the
thermometer.
Attention
Take care of the temperature probe lens, which is fragile.
Dispose used batteries with care. To protect the environment, you
are recommended to send the used batteries to a designated
collection point.

3
Remove the batteries if the thermometer will not be used for more
than two months.
Do not immerse the thermometer in water or expose it to direct
sunlight.
Do not subject the thermometer to vibration or impact.
The normal body temperature varies from person to person.
Tracking a person's body temperature will help determine whether
they have fever.
Do not take body temperature readings within 20 minutes after you
do physical exercises or get excited.
Clean the thermometer probe after each use.
Do not use the thermometer on newborns or for continuous
temperature monitoring purposes.
Do not use the thermometer for purposes that are not specified in
this User’s Manual. Follow the instructions in the "Measurement
Process" chapter and carefully operate the thermometer when
measuring children's temperature.
Do not immerse the thermometer in water or other liquid, as it is
not waterproof. Clean and disinfect the thermometer as described
in the "Cleaning and Disinfection" chapter.
Do not touch the tip of the temperature probe, on which a precise
temperature sensor resides.
Keep the temperature probe clean to make sure accurate readings.
Before measuring the temperature from the ear canal, clean the

4
earwax, if any.
The ambient temperature must not be extremely high or low. To
make sure accurate readings, keep the thermometer under room
temperature for more than 30 minutes before use.
Do not use the thermometer under an ambient temperature higher
than 40°C (104°F) or lower than 10°C (50°F), which is beyond the
operating temperature range of the thermometer.
Risk of pollution! The user is recommended to send the overdue
thermometer to local garbage disposal site or send it back to us.
2 AAA batteries of 1.5V are the only replaceable accessories of the
thermometer. Please do not use the batteries of other voltages or
specifications.
Warning
Warning
Do not force the temperature probe of the thermometer into an ear
canal. Otherwise, the ear canal may get injured.
Keep the thermometer out of the reach of children.
The result may be inaccurate if you use the overdue thermometer.
The thermometer is not intended to diagnose or treat any health
problem or disease. The measurement results are for reference
only.

5
It is dangerous to make a self-diagnosis or self-treatment based on
the obtained measurement results. For such purposes, please
consult a doctor.
Do not charge an alkaline dry-cell battery or throw it in fire.
Otherwise, the battery may explode.
Do not disassemble the thermometer or attempt to repair it.
Otherwise, the thermometer may be damaged permanently.
Do not take temperature measurements on body parts other than
forehead and ears. Otherwise, the temperature readings may be
inaccurate.
During measurement, do not use a mobile phone or any other
device that may cause electromagnetic interference.
Do not use the thermometer in an environment where flammable
anesthetic mixture with air or with oxygen or nitrous oxide is
available.
Symbols
Symbol
Description
Type BF applied part.
Attention must be paid.
The action is prohibited.

6
Symbol
Description
Information about the manufacturer.
Date of manufacture.
Consult the instructions for use.
This product complies with the MDD93/42/EEC
requirements.
Waste electrical materials should be sent to a
dedicated collection point for recycling.
Warning
A personal injury or damage to the thermometer may
occur if the thermometer is not used correctly.
Attention
Inaccurate reading or damage to the thermometer may
occur if the thermometer is not used correctly.
Non-ionizing radiation
Body Temperature Basics
•The normal body temperature is a range.
•The normal range varies from person to person and can fluctuate
throughout the day.
•The normal range also varies by body site. Therefore, measurements
from different sites should not be compared directly.

7
To determine if an individual is experiencing an elevated body temperature
and/or having a fever, it is critical to know the individual’s normal body
temperature when he/she is well. Take multiple readings to obtain the
normal body temperature range and note the specific body site measured,
for example: forehead or eardrum temperature.
The normal body temperature range varies slightly with age and gender.
Generally, newborns or children have higher body temperatures than
adults, and adults have higher body temperatures than the elderly.Women's
body temperatures are approximately 0.3°C (0.5 °F) higher than men's.
Variation in body temperature
Body Site
Normal Temperature Range
Forehead
34.7°C-37.3°C (94.5°F- 99.1°F)
Eardrum
35.8°C-38.0°C (96.4°F-100.4°F)
Mouth
35.5°C-37.5°C (95.9°F- 99.5°F)
Armpit
34.7°C-37.3°C (94.5°F- 99.1°F)
Rectal
36.6°C-38.0°C (97.9°F-100.4°F)
Normal body temperature
fluctuates throughout the day and
is also affected by external
factors.The body temperature of
an individual is the lowest
between 2:00 a.m. and 4:00 a.m.
and the highest between 2:00
p.m. and 8:00 p.m. An
individual's body temperature
typically changes by less than
1°C (1.8°F) each day.
Table of contents
Other Jumper Thermometer manuals

Jumper
Jumper JPD-FR202 User manual

Jumper
Jumper JPD-FR409 User manual

Jumper
Jumper JPD-FR300 User manual

Jumper
Jumper JPD-FR412 User manual

Jumper
Jumper JPD-FR300 User manual

Jumper
Jumper JPD-FR403 User manual

Jumper
Jumper ThermoCheck TC 700 User manual

Jumper
Jumper JPD-FR410 User manual

Jumper
Jumper JPD-FR412 User manual