WARNING
1. Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
2. The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater.)
3. Do not pierce or burn.
4. Be aware that refrigerants may not contain an odour.
5. Appliance shall be installed, operated and stored in a room with a floor area
larger than 12m2.
6. Keep any required ventilation openings clear of obstruction;
7. Servicing shall be performed only as recommended by the manufacturer.
8. The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
9. Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment
specification.
10. Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
11. All working procedure that affects safety means shall only be carried by
competent persons.

Notes:
* The air conditioning is only suitable for indoor use, and is not suitable for
other applications.
* Follow local grid interconnection rules while installing the air conditioning
and ensure that it is properly grounded. If you have any questions on
electrical installation, follow the instructions of the manufacturer, and if
necessary, ask a professional electrician to install it.
* Place the machine in a flat and dry place and keep a distance of over 50cm
between the machine and the surrounding objects or walls.
* After the air conditioning unit is installed, ensure that the power plug is intact
and firmly plugged into the power outlet, and place the power cord orderly to
prevent someone from being tripped or pulling out the plug.
* Do not put any object into the air inlet and outlet of the air conditioning. Keep
the air inlet and outlet free from obstructions.
* When drainage pipes are installed, ensure that the drainage pipes are
properly connected, and are not distorted or bent.
* While adjusting the upper and lower wind grill strips of the air outlet, please
do so gently to avoid damaging the wind grill strips.
* When moving the machine, make sure that it is in an upright position.
* The machine should stay away from gasoline, flammable gas, stoves and
other heat sources.
* Don't disassemble, overhaul and modify the machine, otherwise it will cause
a machine malfunction or even bring harm to persons and properties. To avoid
danger, if a machine failure occurs, ask the manufacturer or professionals to
repair it.
* Do not install and use the air conditioning in the bathroom or other humid
environments.

* Do not pull the plug to turn off the machine.
* Do not place cups or other objects on the body to prevent water or other
liquids from spilling into the air conditioning.
* Do not use insecticide sprays or other flammable substances near the air
conditioning.
* Do not wipe or wash the air conditioning with chemical solvents such as
gasoline and alcohol. When you need to clean the air conditioning, you must
disconnect the power supply, and clean it with a damp soft cloth. If the
machine is really dirty, scrub with a mild detergent.
* The appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities if they have
been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with
the appliance. Cleaning and maintenance shall not be made by children
without supervision.

Features and Components
Features
Cooling, dehumidification and fan functions
Class A energy rating
Compact design
LED display control panel
Castor wheels for easy movement
Sleep mode (quiet setting)
24 hour timer
Remote control
Water full indicator
Air filtration capacity
Components

Exhaust Pipe Assembly
Window Sealing Plate Assembly

Fig.3
Installation and Adjustment
Warning: before using the mobile air conditioning, keep it upright for at least
two hours.
The air conditioning unit can be easily moved in the room. When moving the
machine, please ensure that the air conditioning unit is in the upright position
and is placed on a flat surface. Do not install and use the air conditioning unit
in the bathroom or other humid environments.
1.1 Install the heat pipe assembly (as shown in Fig.1): screw the heat pipe
assembly (exhaust fitting end) into the exhaust port on the rear panel.
1.2 Install the window sealing plate assembly
1) Half open the window and mount the window sealing plate assembly to the
window (as shown in Fig.2 and Fig.3); the assembly can be placed in
horizontal and vertical direction.
2) Pull various components of the window sealing plate assembly open, adjust
their opening distance to bring both ends of the assembly into contact with the
window frame, and fix various components of the assembly.1.2 Install the
window sealing plate assembly
Fig.1
Fig.2

1.3 Install the body
1) Move the machine with installed heat pipe and fittings before the window,
and the distance between the body and walls or other objects shall be least
50 cm (as shown in Fig.4).
2) Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints
into the hole of the window sealing plate assembly (as shown in Fig.5 and
Fig.6).
Notes: 1. the flat end of the exhaust pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater
than 45 °). Keep the ventilation of the exhaust pipe not blocked.
Fig.4
Fig.6
Fig.5

Important Notice
The length of the exhaust hose shall be 280 - 1,500mm, and this length is
based on the specifications of the air conditioning unit. Do not use extension
tubes or replace it with other different hoses, or this may cause a malfunction.
The exhaust hose must be not blocked; otherwise it could cause overheating
or damage to the machine.
Control Panel Setting
I. Operating instructions:
Control Panel is as follows:

II. Operating Instructions of the Remote Control
The remote control panel is as follows:
Instructions of key operation of the high-quality remote control are as follows:
1. Power: press the key to turn on or turn off the machine.
2. Mode: press the key to switch between cooling, fan and
dehumidifying mode.
3. Up: press +the key to increase temperature and timing set value.
4. Down: press -the key to reduce temperature and timing set value.
5. Fan: press the key to select high, medium and low wind speed.
6. Timer: press the key to set timing value.
7. Cleaning: press the louver will swing up and down.
This manual suits for next models
1
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual