ENGLISH
DEUTSCH
SVENSKA

Copyright © 2021 Interspiro
This publication contains or refers to proprietary information which is protected by copyright. All
rights are reserved. Interspiro®, Oxydive® and Divator® are registered trademarks belonging to
Interspiro. This publication may not be copied, photocopied, reproduced, translated, or converted to
any electronic or machinereadable form in whole or in part, without prior written approval from
Interspiro.

Table of Contents
RS4 .......................................................................................................... 5
Introduction and safety ....................................................................... 5
Safety terminology and symbols ................................................. 5
Safety notice ............................................................................. 5
Product description ............................................................................ 8
Main components ...................................................................... 8
Divator RS4 regulator versions ................................................... 8
Preparation ..................................................................................... 11
Adjusting the Divator RS4 before the first use ............................ 11
Assembling the Divator RS4 on the cylinder .............................. 12
Attaching a device to the second high pressure outlet ................ 12
Attaching and directing hoses on Divator BC use ....................... 12
Connecting the breathing hose ................................................. 13
Connecting the inflation hose .................................................... 13
Connecting the octopus breathing hose and valve ..................... 14
Attaching the RS4 regulator pressure gauge .............................. 14
Connecting the Divator DP1 hose ............................................. 15
Pre-dive procedures ......................................................................... 16
Overall check .......................................................................... 16
Checking O-rings ..................................................................... 16
Leakage and function test of the Divator RS4 regulator .............. 17
Checks during diving ........................................................................ 19
Post-dive procedures ....................................................................... 20
Transport and storage ...................................................................... 21
RS4 ........................................................................................................ 23
Einführung und Sicherheit ................................................................ 23
Sicherheitsbegriffe und -symbole .............................................. 23
Sicherheitshinweis ................................................................... 23
Produktbeschreibung ....................................................................... 26
Hauptkomponenten ................................................................. 26
Divator RS4 Regulator-Versionen ............................................. 26
Vorbereitung .................................................................................... 29
Das Einstellen des Divators RS4 vor dem ersten Gebrauch ........ 29
Montage des Divator RS4 an der Flasche ................................. 30
Anschließen eines Geräts an den zweiten Hochdruckauslass ..... 31
Anbringen und Ausrichten von Schläuchen am Divator BC ......... 31
Anschluss des Atemschlauches ................................................ 31
Anschluss des Inflatorschlauches ............................................. 32
Anschluss des Oktopus-Lungenautomaten und -Schlauchs ........ 33
RS4 • RS4 • RS4
3

Anbringen des Manometers am RS4-Regulator ......................... 33
Anschließen des Divator DP1-Schlauchs ................................... 34
Maßnahmen vor dem Tauchgang ...................................................... 35
Vollständige Prüfung ................................................................ 35
Prüfen der O-Ringe .................................................................. 35
Leckage- und Funktionstest des Divator RS4 Regulators ........... 36
Maßnahmen während des Tauchgangs ............................................. 38
Maßnahmen nach dem Tauchgang ................................................... 39
Transport und Aufbewahrung ............................................................ 40
RS4 ........................................................................................................ 41
Introduktion och säkerhet ................................................................. 41
Säkerhetstermer och symboler ................................................. 41
Säkerhetsföreskrifter ................................................................ 41
Produktbeskrivning .......................................................................... 44
Huvudkomponenter ................................................................. 44
Versioner av Divator RS4 ......................................................... 44
Förberedelse ................................................................................... 47
Justera Divator RS4 före första användningen ........................... 47
Montera Divator RS4 på flaskan ............................................... 48
Montera ett tillbehör på den andra högtrycksanslutningen .......... 48
Fästa och rikta slangar vid Divator BC användning .................... 48
Montera andningsslangar ......................................................... 49
Montera uppblåsningsslangen .................................................. 50
Montera slangen till sekundär andningsventil (octopus) .............. 50
Montering av manometern på RS4 regulatorn ............................ 51
Montera Divator DP1 dykslang ................................................. 51
Före dyk .......................................................................................... 52
Översyn .................................................................................. 52
Kontroll av o-ringar .................................................................. 52
Läckage och funktionstest av Divator RS4 regulatorn ................. 53
Under dyk ....................................................................................... 55
Efter dyk ......................................................................................... 56
Transport och förvaring .................................................................... 57
RS4 • RS4 • RS4
4

Introduction and safety
Safety terminology and symbols
In this document, the terms WARNING and NOTICE are used to indicate
potential hazards. Read the accompanying information carefully and follow the
safety instructions.
WARNING
The WARNING type of hazard statement signifies that there is
a risk of serious injury or death.
NOTICE
The NOTICE type of hazard statement signifies that there may
be a risk of damage to equipment or property.
Safety notice
This product, supplying breathing gas to the user, has been tested in
accordance with EN250, and is to be used according local regulations.
It is approved for a range of 0-50 meters (0-164 feet) depth and for cold water
temperatures down to 4 ± 2 °C (39,2 ± 3,6 °F) in accordance with EN 250.
Manufacturer: Interspiro AB, Box 2853 18728 Täby Sweden
Interspiro is not responsible for:
• combinations of products, unless put to market by Interspiro
• changes or adaptations made to the product by a third party
RS4
5
ENGLISH

WARNING
BEFORE USING THE DIVATOR RS4, THE USER MUST
HAVE RECEIVED FULL TRAINING IN ITS USE, HAVE READ
AND UNDERSTOOD THESE OPERATING INSTRUCTIONS
AND DEMONSTRATED PROFICIENCY TO A RESPONSIBLE
TRAINER OR SUPERVISOR. FAILURE TO DO SO MAY
RESULT IN INJURY OR DEATH FOR THE USER AND CAN
HAVE SERIOUS CONSEQUENCES FOR PEOPLE TO BE
RESCUED AND/OR ITEMS OF VALUE TO BE SAVED.
WARNING
ALL USERS OF THE DIVATOR SYSTEM MUST BE
CERTIFIED BY A NATIONALLY OR INTERNATIONALLY
RECOGNIZED SCUBA CERTIFICATION AGENCY.
FURTHERMORE, ALL USERS OF THE DIVATOR SYSTEM
MUST BE ADEQUATELY TRAINED IN ITS USE BY A
CERTIFIED SCUBA INSTRUCTOR WITH KNOWLEDGE
AND EXPERIENCE IN THE USE OF THE DIVATOR DIVING
SYSTEM.
WARNING
ALL USERS OF THE DIVATOR SYSTEM MUST
PERIODICALLY UNDERGO TRAINING IN EMERGENCY
PROCEDURES IN SHALLOW WATER TO MAINTAIN
PREPAREDNESS IN THE EVENT OF AN ACTUAL
EMERGENCY.
RS4
6

WARNING
HIGH PRESSURE GAS SYSTEMS MUST BE HANDLED
WITH CARE. DAMAGE TO HIGH PRESSURE GAS SYSTEM
COMPONENTS MAY RESULT IN INJURY OR DEATH.
INTERSPIRO IS NOT LIABLE FOR DAMAGES INCURRED
AS A CONSEQUENCE OF FAILURE TO FOLLOW THE
INSTRUCTIONS IN THIS MANUAL
WARNING
THE BREATHING AIR SHALL MEET THE REQUIREMENTS
FOR BREATHABLE AIR ACCORDING TO EN 132 ANNEX A,
OR SIMILAR PURITY REQUIREMENTS.
RS4
7
ENGLISH

Product description
Main components
1
8
9
3
57
6
10
2
4
1. Regulator, first stage
2. Anti-freeze device (maintenance free)
3. Pressure gauge, displaying pressures from 0 to 300 bar, or 0 to 4350 Psi
(photo shows pressure gauge with optional compass and depth gauge)
4. High pressure hose
5. Quick connector for DP1 with protective rubber cap (optional)
6. Dry suit hose (optional)
7. Octopus hose (optional)
8. BC hose (optional)
9. Breathing hose for full face mask or breathing valve with mouth piece
(optional)
10. Parking plug (optional)
Divator RS4 regulator versions
The RS4 Regulator is available with DIN or YOKE connection. It can be
configured with one or two LP covers and with or without DP1 Surface supply
RS4
8

connection. The DIN versions are using one HP connection for a parking plug
for keeping the dust cover in place during the dive.
LP connections
• 2 LP outlets (3/8”) are available on each cover. They can be used to connect
breathing/octopus valves, dry suits, BC hoses or any additional LP hoses.
HP connection
• The regulator has 2 HP outlets (7/16”). They can be used to connect a
pressure gauge, the Divator HUD or other HP devices.
DP1 connection
• The DP1 connection is added to the top cover of the RS4 regulator to
connect to the P+ regulator of the Divator DP1 surface supply system.
NOTICE
If the RS4 regulator shall be used without a Divator breathing
valve (which can release overpressure) connected to it, it must
be equipped with a relief valve.
RS4
9
ENGLISH

1. Yoke cylinder connection. One LP cover with one safety valve.
2. DIN cylinder connection. Pressure gauge hose. Two LP covers.
3. DIN cylinder connection. Pressure gauge hose. Two LP covers.
DP1connection.
RS4
10
Table of contents
Languages:
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions