iFan IF9010 User manual

iFAN 3IN1 PORTABLE AIRCON AIR CONDITIONER / FAN / DEHUMIDIFIER
IF9010

Parts & Description s
LIST OF COMPONENTS
1.
Control Panel
5.
Top Cover
2.
Air Outlet Louvre
6.
Decorative Box
3.
Front Housing
7.
Side Plate
4.
Base Plate
8.
Rear Housing
9.
Caster
Control Panel ①
Air Outlet Louvre ②
Front Housing ③
Base Plate ④
⑤&&Top Cover
⑥&&Decorative Box
⑦&&Side Plate
⑧&&Rear Housing
⑨&&Caster

10.
EVA Filter
11.
Continuous Drainage Hole
12.
Air Vent
13.
Wrapping Post
14.
Con Filter
15.
Drainage Hole
⑩&&EVA Filter
⑪&&Continuous Drainage Hole
⑫&&Air Vent
⑬&&Wrapping Post
⑭&&Con Filter
⑮&&Drainage Hole
Exhaust Pipe Assembly
Window Sealing Plate Assembly

INSTALLATION GUIDE s
1.
INSTALLATION
Warning: before using the portable air conditioner, keep it upright for at least
2 hours. When moving the appliance, ensure that it is kept upright on a
horizontal and dry surface.
1.1
Screw the Exhaust Pipe Assembly (exhaust fitting end) into the exhaust port
on the rear panel (Fig. 1).
Exhaust Pipe Assembly Fig. 1
1.2
Half open the window, and mount the Window Sealing Plate Assembly to
the window in either horizontal (Fig. 2) or vertical (Fig. 3) directions.
To do so, you may have pull various components of the Window Sealing
Plate Assembly open to adjust their opening distance to bring both ends of
the assembly into contact with the window frame
Window Sealing Plate Assembly Fig. 2 Fig. 3
1.3
Place the Main Body with installed
Exhaust Pipe Assembly and fittings
before the window, and the distance
between the body and walls or other
objects shall be least 50 cm (Fig.4).
Fig. 4

2
Elongate the Exhaust Pipe. Snap the flat end of the Exhaust Pipe joints into
the hole of the Window Sealing Plate Assembly into place.
The Exhaust Pipe cannot be distorted nor subject to substantial turning
angle (greater than 45 °). Keep the ventilation of the Exhaust Pipe unlocked.
(Fig.5 & Fig.6).
Fig. 5 Fig. 6
Note:
The length of the Exhaust Pipe shall be between 280 ~ 1500 mm, and this
length is based on the specifications of the air conditioner DO NOT use
extension tubes or replace it with other different hoses, or this may cause a
malfunction. Exhaust Pipe must be unblocked; otherwise it may cause
overheating.


HOW TO USEs
LED CONTROL PANEL
REMOTE CONTROL PANEL
①""""""""""""""""" ②""""""""""""""""""""""""""""""""""""""""""""""" ③"""""""""""""""""""""""" ④ ⑤ ⑥
""""""""""""""" ②""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
④
③" UP
⑤
①"
③"DOWN
"
!
⑥
TIMER SPEED SWING SLEEP MODE POWER
SWING

①""
TIMER
When appliance is ON, press the TIMER key to exit. When appliance
is OFF, press the TIMER key to input.
Press the Timer key ® Symbol flashes ® Press UP or DOWN key to
set Timer (adjusted UP by one hour or Down by one hour, from
1 – 24 hours)
②""""
WIND
SPEED
SELECTION
When in FAN or COOL Mode (see 5), press key to toggle between
HIGH or LOW wind speed.
When in DEHUMIDIFY Mode, pressing the key does not work as it is
set to the LOW wind speed mode permanently.
③
UP / DOWN
Adjusts the Temperature or Timer settings.
④
SLEEP
In COOL mode, pressing the SLEEP key turns on Energy saving
operation. Does not work in DEHUMIDIFY or FAN modes.
⑤
FAN MODE
Press to toggle between
FAN ® DEHUMIDIFY ® COOL modes.
⑥
WATER
FULL
The lamp will light and buzzer will sound for several seconds to
indicate that the Water Pan inside the appliance is full.
POWER
To turn the appliance ON and OFF.

SAFETY FUNCTIONS
1.
Frost Protection Function
In COOL, DEHUMIDIFY or SLEEP mode, if the temperature of the exhaust pipe is
too low, the appliance will automatically enter protection status; if the temperature of
the exhaust pipe rises to a certain temperature, it automatically reverts to normal
operation.
2.
Automatic Defrosting
The appliance has Automatic Defrosting function.
3.
Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.
4.
Overflow Protection Function
When water in the Water Pan exceeds the warning level, the appliance will
automatically sound an alarm, and the "FULL" indicator light will flash. The appliance
will stop operating. Follow the instructions below.
After the water is emptied, the appliance will automatically return to the original state.

HOW TO DRAIN AND STORE
1.
Manual Drainage
a.
Turn the wall switch OFF and unplug the power cable from the wall socket.
b.
Move the ②"Drainage Pipe connecting the appliance to a toilet or other drainage area
to empty the water. You may have to carefully move the appliance, as well.
c.
Unscrew the ①"Drainage Plug from the Drainage Hole. Water will automatically flow
out of the Water Pan. During drainage, the body of the appliance can be tilted slightly
backwards
d.
Re-attach the ①" Drainage Plug securely. Restart the appliance immediately.
Otherwise, condensate water of the appliance will flow to the floor.
Drainage Plug""
①"""""""""""""""""
②""Drainage Pipe!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Table of contents
Other iFan Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual