HTW P20 User manual

P20
OWNER’S MANUAL
PORTABLE
ENGLISH
HTW-PC-021P20
Thanks for choossing our product.
Please, read carefully this manual
before using the product

17
Content
I. Notes ................................................................................................................................................... 18
II. Features and Components .......................................................................................................... 19
III. Installation and Adjustment ........................................................................................................ 21
IV. Control Setting ............................................................................................................................... 23
V. Drainage Instructions .................................................................................................................... 25
VI. Maintenance .................................................................................................................................. 26
VII. Troubleshooting ............................................................................................................................ 27
VIII. Appendix ....................................................................................................................................... 28
P20 Series
Thank you for choosing the luxurious and elegant mobile air conditioning. Please keep the ma-
nual for later review, and read the manual carefully before use.

18
Notes
* The air conditioning is only suitable for indoor use, and is not suitable for other applications.
* Follow local grid interconnection rules while installing the air conditioning and ensure that it is
properly grounded. If you have any question on electrical installation, follow the instructions of
the manufacturer, and if necessary, ask a professional electrician to install it.
* Place the machine in a at and dry place and keep a distance of above 50cm between the
machine and the surrounding objects or walls.
* After the air conditioning is installed, ensure that the power plug is intact and rmly plugged
into the power outlet, and place the power cord orderly to prevent someone from being tripped
or pulling out the plug.
* Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and
outlet free from obstructions.
* When drainage pipes are installed, ensure that the drainage pipes are properly connected, and
are not distorted or bended.
* While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently
to avoid damaging wind-guide strips.
* When moving the machine, make sure that it is in an upright position.
* The machine should stay away from gasoline, ammable gas, stoves and other heat sources.
* Don’t disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a
machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine
failure occurs, ask the manufacturer or professionals to repair it.
* Do not install and use the air conditioning in the bathroom or other humid environments.
* Do not pull the plug to turn off the machine.
* Do not place cups or other objects on the body to prevent water or other liquids from spilling into
the air conditioning.
* Do not use insecticide sprays or other ammable substances near the air conditioning.
* Do not wipe or wash the air conditioning with chemical solvents such as gasoline and alcohol.
When you need to clean the air conditioning, you must disconnect the power supply, and clean
it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
* The appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and maintenance shall not be made by children
without supervision.

19
Features and Components
1. Features
New look, compact structure, streamlined machine, aristocratic atmosphere.
With cooling,dehumidication and fan function, Continuous Water Drainage Functions.
LED displays the control panel. The machine is beautiful and elegant. High-quality remote
control is equipped to facilitate operation. It adopts a user-friendly remote control design.
Outdoor interface is set high to facility assembly and keep the smooth ow of the heat pipe.
Air ltration capability.
Timing switch function.
Protection function of automatically restarting the compressor after three minutes, a variety of
other protection functions.
Components
Top Cover
Handle
Rear
Housing
Caster
Control
Panel
Air Outlet /
Louver
Front
Housing

20
EVA Filter Front Housing
Handle
Rear Housing
Continuous
drainage hole
Air Vent
CON Filter
Drainage Hole
Exhaust Pipe
Assembly
Window Seating
Plate Asembly

21
Installation and Adjustment
1. Installation:
Warning: before using the mobile air conditioning, keep it upright for at least two hours.
The air conditioning can be easily moved in the room. In the moving process, ensure that the
air conditioning is in the upright position and the air conditioning should be placed on a at
surface. Do not install and use the air conditioning in the bathroom or other humid environ-
ments.
1.1 Install the heat pipe assembly (as shown in Fig.1): screw the heat pipe assembly (exhaust
tting end) into the exhaust port on the rear panel.
1.2 Install the window sealing plate assembly
1) Half open the window, and mount the window sealing plate assembly to the window (as
shown in Fig.2 and Fig.3); the assembly can be placed in horizontal and vertical direction.
2) Pull various components of the window sealing plate assembly open, adjust their opening
distance to bring both ends of the assembly into contact with the window frame, and x va-
rious components of the assembly.1.2 Install the window sealing plate assembly
1.3 Install the body
1) Move the machine with installed heat pipe and ttings before the window, and the distance
between the body and walls or other objects shall be least 50 cm (as shown in Fig.4).
Fig. 4
Fig. 1
Fig. 2 Fig. 3

22
2) Elongate the exhaust pipe and snap the at end of the exhaust pipe joints into the hole of
the window sealing plate assembly (as shown in Fig.5 and Fig.6) .
Notes: 1. the at end of the exhaust pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep
the ventilation of the exhaust pipe not blocked.
Important Notice
The length of the exhaust hose shall be 280~1,500mm, and this length is based on the spe-
cications of the air conditioning. Do not use extension tubes or replace it with other different
hoses, or this may cause a malfunction. Exhaust host must be not blocked; otherwise it may
cause overheating.
Fig. 5 Fig. 6

23
Control Panel Setting
I. Operating instructions:
LED Control Panel is as follows:
1. Timer Key 2. Fan Speed Selection Key 3. Up Key 4. Display Window
5. Down Key 6.Mode Selection Key 7. Power Key
1. When the machine is powered on for the first time, the buzzer will play power-on music, and
then the machine will get into standby status.
2. Power Key: press the key to turn on and turn off the machine. In the case of power on,
press the key to turn off the machine; in the case of power off, press the key to turn on the
machine.
3. Mode Selection Key: In the case of power on, press the key to switch between:
cooling → d ehumidifying mode → fan.
4. Up Key and Down Key: press the two keys to change the setting temperature or setting
time, operate as follows:
While setting temperature, press up key or down key to select the required temperature (not
available in fan or dehumidifying mode).
While setting time, press up key or down key to select the required time.
5. Fan Speed Selection Key:
In cooling mode, press the key to select high, medium or low wind speed operation.
In fan mode, press the key to select high, medium or low wind speed operation.
In heating mode, press the key to select high, medium and low wind speed operation.
In dehumidification mode, pressing the key is invalid, and the fan will forcibly choose low
wind speed operation.
6. Timing Key:
In the case of power on, press the key to close timing; in the case of power off, press the key
to open timing.
Press the key, when the timing symbol ashes, press up and down key to select the required
timing value.
Timing values can be set in 1-24 hours and the timing value is adjusted up or down by one
hour.
7. Sleep Mode:
In the cooling Mode,Press the UP and Fan Key to turn on the sleep mode,then the unit will
work on Energy-Saving and quiet type.
Note: Can not turn on the sleep mode in the dehumidifying or Fan mode!
1 2 3 4 5 6 7

24
II. Operating Instructions of the Remote Control
The remote control Panel is as follows:
Instructions of key operation of the high-quality remote control are as follows:
1. Power:
2. Timer:
3. Down:
4. Mode:
5. Up:
Press the key to turn on or turn off the machine.
press the key to set timing value. Timing value can be set with 1-24 hours
and the timing value is adjusted upwards or downwards by one hour.
press the key to reduce temperature and timing set value.
press the key to switch between cooling, dehumidifying mode, fan.
press the key to increase temperature and timing set value.
6. Fan: press the key to select high, low wind speed.
7. Sleep Mode: Press the key to turn on the sleep mode.
III. A Variety of Protection Functions
3.1 Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of the EVA
pipe sensor is too low, the machine will automatically enter protection status; if the
temperature of the EVA pipe sensor rises to a certain temperature, it can automatically revert
to normal operation.
3.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound
an alarm, and the W.F indicator will flash. At this point, you need to drainage the water
(details see Drainage Instructions at the end of this chapter). After the water is emptied, the
machine will get into standby status.
3.3 Automatic Defrosting:
In heating, the machine has automatic defrosting function. After defrosting, the machine will
automatically return to the original status.
3.4. Overheat Protection:
To protect the service life of the machine, the machine has overheat protection in heating
mode. During the protection period, the compressor and the lower motor will stop operation
and will automatically return to normal heating state after the temperature of the machine
recovers.
3.5 Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection
function after the compressor is turned off.

25
Drainage Instructions
1. Manual drainage:
1) When the machine stops after the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at
the bottom of the body.
2) Place the water container below the side water outlet behind the body.
3) Unscrew the drainage cover and unplug the water plug, the water will automatically ow
into the water container.
Notes:
1. Keep the drainage cover and the water plug properly.
2. During drainage, the body can be tilted slightly backwards.
3. If the water container cannot hold all the water, before the water container is full, stuff the
water outlet with the water plug as soon as possible to prevent water from owing to the
oor or the carpet.
4) When the water is discharged, stuff the water plug, and tighten the drainage cover.
Notes: 1. Restart the machine after the water plug and drainage cover are installed, otherwi-
se condensate water of the machine will ow to the oor or the carpet.
2. Continuous drainage (Optional) (only applicable to cooling and
dehumidifying mode), as shown in gure:
1) Unscrew the drainage cover, and unplug the water plug.
2) Set the drainage pipe into the water outlet.
3) Connect the drainage pipe to the bucket.
This manual suits for next models
1
Table of contents
Other HTW Air Conditioner manuals

HTW
HTW IX41B User manual

HTW
HTW HTW-MSI-026IX21D4R32 User manual

HTW
HTW ADMIRA HTW-C6-035ADMR32 Service manual

HTW
HTW HTW-MKG-V300C User manual

HTW
HTW ECO-THERMAL R32 Series Product guide

HTW
HTW HTWS026IX21D4-R32 User manual

HTW
HTW P21 User manual

HTW
HTW INNOVA HTWS026INNR32-EXT Service manual

HTW
HTW PREMIUM R32 Service manual

HTW
HTW IX21D4 User manual
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual