HeatSeeker VORTEXC Instruction Manual

Heatseeker VortexC Inverter Heat Pump
Installation & User Manual 1
INSTALLATION & USER MANUAL

Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
2supremeheating.com.au
1300 787 978
Head Ofce
2/ 19 Enterprise Drive
Bundoora VIC 3083
P: (03) 9460 4200
F: (03) 9460 4900
info@supremeheating.com.au
supremeheating.com.au
NSW Ofce
19/24 Anzac Avenue
Smeaton Grange NSW 2567
P: (02) 4648 4766
M: 0448 959 666
M: 0438 471 381
solar.nsw@supremeheating.com.au
salesnsw@supremeheating.com.au
QLD Ofce
Unit 13, 53-57 Link Drive
Yatala QLD 4207
P: (07) 3807 6308
F: 1300 887 879
M: 0455 064 765
solarqld@supremeheating.com.au
SA Ofce
Unit 4, 7-9 Streiff Road
Wingeld SA 5013
P: 1300 787 978
F: 1300 887 879
M: 0437 947 375
solarsa@supremeheating.com.au
WA Ofce
South Fremantle WA 6162
P: (08) 9433 5588
solar@supremeheating.com.au

INSTALLATION & USER MANUAL
FOR USERS
1. General information 02
1.1. Contents 02
1.2. Operating conditions and range 02
1.3. Advantages of different modes 02
1.4. Kind reminder 03
2. Operation 06
2.1. Notice before using 06
2.2. Operation instructions 06
2.3. Daily maintenance and winterizing 08
3. Technicalspecication 09
FOR INSTALLERS AND PROFESSIONALS
4. Transportation 10
5. Installation and maintenance 11
5.1. Notice before installation 11
5.2. Installation instructions 12
5.3. Trial after installation 17
6. Trouble shooting for common faults 18
7. Error codes 19
ANCILLARY PRODUCTS
8. VortexSwitch 20
8.1. Operation 20
8.2. Heating priority 20
8.3. Installation instructions 21
9. VortexLink 22
9.1. Operation 22
9.2. Heat demand 22
9.3. Installation instructions 23
WARRANTY
11. Warranty agreement 24
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual 01

1. GENERAL INFORMATION
1.1. CONTENTS:
After unpacking, please check that you have all the following components.
1.2. OPERATING CONDITIONS AND RANGE
ITEMS RANGE
Operating Range Air temperature -7°C - 43°C
Temperature Setting Heating 18°C - 35°C
Cooling 12°C - 30°C
The heat pump will have ideal performance in the operation range Air 15°C - 25°C
1.3. ADVANTAGES OF DIFFERENT MODES
The heat pump has two modes: Smart and Silence. They have different advantages under different
conditions
MODE RECOMMENDATION ADVANTAGES
Smart mode
As standard
Heating capacity: 20% to 100% capacity
Intelligent optimisation
Fast heating
Silence mode
Use at night
Heating capacity: 20% to 80% capacity
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
02

1.4. KIND REMINDER
ATTENTION
This heat pump has power-off memory function. When the power is recovered, the heat
pump will restart automatically.
1.4.1. The heat pump can only be used with pool water. It can NEVER be used to heat or cool other
ammable or turbid liquid.
1.4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat
exchanger.
�
�
1.4.3. Do not obstruct the air inlet or outlet of the heat pump.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual 03

1.4.4. Do not obstruct or insert any objects into inlet or outlet of the heat pump. The efciency may
be reduced or even stopped.
1.4.5. To avoid re hazards, do not store or use combustible gas or liquids such as thinners, paints
or fuels near the heat pump.
1.4.6. If you detect any abnormal noises, odours, smoke or leaks from the heat pump, immediately
switch off the power supply and contact your local dealer. Do not attempt to repair the heat
pump yourself.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
04

1.4.7. Please note that following codes are not failures.
CODES
Nowaterow
Anti-freezing reminder
Out of the operating range
Insufcientwateroworpumpblocked
Power abnormal
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual 05

2. OPERATION
2.1. NOTICE BEFORE USING
1. Users are advised to start the water
circulation prior to turning on the heat
pump. It is also recommended that the
heat pump be turned off prior to the
interruptionofwaterow.
2. Check for any water leakage in connecting
pipework, then turn on the power supply,
press the ON/OFF button of the heat
pump, and set desired temperature.
2.2. OPERATION INSTRUCTIONS
SYMBOL DESIGNATION OPERATION
Power ON/OFF Press to power on or off the heat pump
Up/ Down Press to set desired water temperature
Heat/Cool/Auto Press to switch between cooling, heating and auto
Fan Press to select Silence mode ON/OFF
Note:
1. You can set the desired water temperature from 12°C to 35°C.
2. The numbers on the right of the display show the inlet water temperature. The numbers on
the left of the display show the outlet water temperature.
3. Turn on the heat pump and the fan will start to run after 3 minutes. In another 30 seconds,
the compressor will start to run.
�C�C
MIN
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
06

2.2.1 Status on the display
Auto
Mode
Defrost
Mode
Heating
Mode
Cooling
Mode
Timer
ON/OFF
2.2.2. Clock setting
1. Hold for5secondstoentertheclocksetting.88:88isashingonthedisplay
2. Press or to adjust the time. Then, press toconrmandexit.
3. If no settings are made within 30 seconds, any changes will be lost and the controller will exit
the clock setting.
2.2.3. Timer on and off
1. Hold the for10secondstoenterthetimersetting.The“ON”willbeashingtoenterthe
Timer ON setting. Press the or to adjust Timer ON time. You can choose Timer ON
(Display: ON), or Repeat Timer ON (Display: 1 ON) by pressing . Then press toconrm.
2. Whenthe“ON”stopsashing,and“OFF”isashing,youentertheTimerOFFmode.Pressthe
or to adjust Timer OFF time. You can choose Timer OFF (Display: OFF), or Repeat Timer
OFF (Display: 2 OFF) by pressing . Then press toconrm.
3. After entering the Timer ON/OFF setting, press directly without adjusting the time to
cancel the relevant Timer setting.
4. If no settings are made within 30 seconds, any changes will be lost and the controller will exit
the Timer ON/OFF setting.
Note: If daily time schedule is required (normal) repeat timers must be set.
2.2.4 Silence mode
1. The Smart mode as default will be activated when the machine is turned on. And the display
shows .
2. When machine is on, press button to enter the Silence mode. will show. Press again
to exit.
2.2.5 Compulsory defrost
1. When the machine is on heating mode and the compressor is working continuously for
10 minutes, press both and buttons for 5 seconds to start compulsory defrost.
(Note: the break between compulsory defrost needs to be more than 30 minutes.)
2. Thedefrostsymbolwillashwhenthemachineisincompulsorydefrostmodeorautodefrost
mode.
3. Compulsory defrost will take the same amount of time as auto defrost.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual 07

2.3. DAILY MAINTENANCE AND WINTERIZING
2.3.1. Daily Maintenance
ATTENTION
Please don’t forget to cut off power supply to the heat pump
1. Please clean the evaporator with household detergents or clean water. NEVER use gasoline,
thinners or any similar fuel.
2. Check bolts, cables and connections regularly.
2.3.2. Winterizing - Sub-Zero Climates
In climates where the winter season reaches sub-zero temperatures, please disconnect from power
supply and drain water out of the heat pump. When using the heat pump under 2°C, make sure
thereisalwayswaterow.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter s eason, t he t itanium hea
t
exchanger may be damaged.
Unscrew the water union of inlet
pipe to let the water flow out.
When the water in machine freezes
in winter season, the titanium heat
exchanger may be damaged.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
08
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual