GE 1200 Series User manual

GE
Security
1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring
Guide

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
2
Copyright Copyright © (2008), GE Security B.V. All rights reserved.
This document may not be copied or otherwise reproduced, in whole or in part,
except as specifically permitted under US and international copyright law,
without the prior written consent from GE.
1060738 / revision: 3-4 (March 2008)
Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. GE ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS
AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR
OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE
USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE
LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE
AT WWW.GESECURITY.NET.
This publication may contain examples of screen captures and reports used in
daily operations. Examples may include fictitious names of individuals and
companies. Any similarity to names and addresses of actual businesses or
persons is entirely coincidental.
Trademarks and patents GE and the GE monogram are registered trademarks of General Electric.
Other trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Software license agreement GE software supplied with GE products is proprietary and furnished under license
and can be used or copied only in accordance with the license terms.
THE ENCLOSED PROGRAM IS FURNISHED SUBJECT TO THE TERMS AND
CONDITIONS OF THIS AGREEMENT. RETENTION OF THE PROGRAM FOR MORE
THAN 30 DAYS, OPENING OF THE SEALED WRAPPER, IF ANY, SURROUNDING THE
PROGRAM, OR USE OF THE PROGRAM IN ANY MANNER WILL BE CONSIDERED
ACCEPTANCE OF THE AGREEMENT TERMS. IF THESE TERMS ARE NOT ACCEPTABLE,
RETURN THE UNUSED PROGRAM AND ANY ACCOMPANYING DOCUMENTATION TO
GE FOR A FULL REFUND OF THE LICENSE FEE PAID. (FOR INFORMATION
REGARDING THE RETURN OF PROGRAMS ENCODED OR INCORPORATED WITHIN
EQUIPMENT, CONTACT THE NEAREST GE SALES OFFICE.)
Intended use Use this product only for the purpose it was designed for; refer to the data sheet
and user documentation. For the latest product information, contact your local
supplier or visit us online at http://www.gesecurity.eu/.
Regulatory
The European directive “Waste Electrical and Electronic Equipment” (WEEE) aims
to minimise the impact of electrical and electronic equipment waste on the
environment and human health. To conform with this directive, electrical
equipment marked with this symbol must not be disposed of in European public
disposal systems. European users of electrical equipment must now return end-
of-life equipment for disposal. Further information can be found on the following
website: www.recyclethis.info.
European representative for manufacture:
GE Security B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands.
?

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
3
Contents
1Preface ..................................................................................................................................... 4
1.1 Conventions used in this manual..................................................................................................4
1.2 Safety terms and symbols................................................................................................................4
2Introduction ............................................................................................................................ 5
2.1 About this document ..........................................................................................................................5
2.2 Internal layout of 2000 series panels..........................................................................................6
2.3 Internal layout of 1200 series panels..........................................................................................7
3Interconnection and wiring.................................................................................................. 8
3.1 Recommended cable..........................................................................................................................8
3.2 Loop card connections ......................................................................................................................8
3.3 Sounder board connections......................................................................................................... 10
3.4 Auxiliary input connections .......................................................................................................... 15
3.5 Power supply connections............................................................................................................ 16
3.6 Network connections....................................................................................................................... 22
3.7 Null modem cable ............................................................................................................................. 25
4First-time start-up and configuration ............................................................................. 26
4.1 First-time start-up............................................................................................................................. 26
4.2 Configuration of 2000 series panels......................................................................................... 26
4.3 Configuration of 1200 series panels......................................................................................... 27
5Maintenance and support.................................................................................................. 28
5.1 Maintenance........................................................................................................................................ 28
5.2 Contacting technical support...................................................................................................... 29
6Technical specifications ..................................................................................................... 30
6.1 Loop specifications........................................................................................................................... 30
6.2 Current loop specifications........................................................................................................... 31
6.3 Panel specifications.......................................................................................................................... 31

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
4
1 Preface
This is the 1200-2000 Series Fire Panels, Repeaters, and Emulators Interconnection and Wiring Guide.
Read these instructions and all ancillary documentation entirely before installing or operating this
product. For in-depth information on installation and wiring refer to the product installation manual.
1.1 Conventions used in this manual
The following conventions are used in this document:
Menu items and buttons.
Bold
Emphasis of an instruction or point; special terms.
Italic
File names, path names, windows, panes, tabs, fields, variables, and other GUI elements.
Titles of books and various documents.
(Electronic version.) Hyperlinks to URL addresses.
Blue italic
Monospace Text that displays on the computer screen.
Programming or coding sequences.
1.2 Safety terms and symbols
These terms may appear in this manual:
Cautions identify conditions or practices that may result in damage to the equipment or other
property.
CAUTION:
Warnings identify conditions or practices that could result in equipment damage or serious personal
injury.
WARNING:

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
5
2 Introduction
For general guidelines on fire system planning, design, installation, commissioning, use and
maintenance refer to the EN54-14 standard and local regulations.
CAUTION:
This is a Class A product and may cause radio interference if installed in a domestic environment.
WARNING:
2.1 About this document
This manual explains how to install 1200 and 2000 series analogue addressable fire panels, repeaters
and emulators. The manual is intended as a guide only and is not to be used to replace any local
building and/or wiring codes.
Addititional information may be found in the following manuals (available from your local supplier):
• 1200-2000 Series Reference Guide.
• 1200-2000 Series Network Configuration Guide.
• 1200-2000 Series Installation And Commissioning Guide.
• 1200-2000 Series User Guide.

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
6
2.2 Internal layout of 2000 series panels
Figure 1: Internal layout of 2000 series panels
1. FEP board
2. Power supply board
3. Loop card
4. Sounder board
5. Programmable relays
6. Fault routing
7. Fire protection
8. Fire routing
9. Fire alarm devices
10. General input
11. Fault routing return input *
12. Fire protection return input *
13. Fire brigade return input *
14. 2 x Class A loops or 4 x Class B loops
15. 4 x auxiliary inputs
*VdS mode only

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
7
2.3 Internal layout of 1200 series panels
Figure 2: Internal layout of 1200 series panels
1. FEP board
2. Power supply board
3. Loop card
4. Sounder board
5. Programmable relays
6. Fault routing
7. Fire protection
8. Fire routing
9. Fire alarm devices
10. General input
11. Fault routing return input
12. Fire protection return input
13. Fire brigade return input
14. 2 x Class A loops or 4 x Class B loops
15. Auxiliary power
16. Fault relay
Jumpers H and L are not included on the LC2002 loop card.
Note:

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
8
3 Interconnection and wiring
The following sections describe the cabling and system interconnection requirements for your
product.
3.1 Recommended cable
Twisted and screened cable is required for all installation cabling. The cable screen should be
connected to the earth stud in the panel.
3.2 Loop card connections
Connect the loop card as shown below and select the loop Class required (see Section 3.2.1).
Figure 3: Loop card connections
1. Class B loop 1
2. Class B loop 2
3. Class B loop 3
4. Class B loop 4
5. Class A loop 1
6. Class A loop 2
7. Class A loop 1 forward
8. Class A loop 1 return

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
9
3.2.1 Loop Class and jumper selection
Figure 4: Location of loop card jumpers for loop Class selection
A. Jumper selection for up to 2 x Class A loops
B. Jumper selection for up to 4 x Class B loops
H. Jumper selection for 900 series and 2000 series protocol

1200-2000 Series Fire Panels, Repeaters, and Emulators
Interconnection and Wiring Guide
10
3.3 Sounder board connections
Figure 5: Location of jumpers on sounder board
1. Sounder board
2. Programmable relays (A = OUT8, B = OUT7, C = OUT6, D = OUT5)
3. Fault routing (OUT4)
4. Fire protection device (OUT3)
5. Fire routing device (OUT2)
6. Fire alarm device (OUT1)
7. General input (IN8)
8. Fault routing fault input (VdS mode only) (IN7)
9. Fire protection fault input (VdS mode only) (IN6)
10. Fire routing feedback input (VdS mode only) (IN5)
This manual suits for next models
28
Table of contents
Other GE Security System manuals
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual