Fluo FSS101EI/JDF-N3 User manual

Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the User's Manual, please contact the local agent or visit www.skyworth-ac.com or sent
USER'S MANUAL
Split Air Conditioner
MODEL
FSS101EI/JDF-N3
FSS121EI/JDF-N3
FSS181EI/JDF-N3
FSS 241 EI/JDF-N3

Operation Notices
Precautions ........................................................................................................ 1
Parts name.......................................................................................................... 6
Operation Guide
Operation guide.................................................................................................. 7
Remote controller .............................................................................................. 8
Buttons on remote controller............................................................................ 9
Indoor unit address inquiry............................................................................. 13
Maintenance
Clean and maintenance................................................................................... 13
Malfunction
Malfunction analysis........................................................................................ 15
Safety operation of ammable refrigerant..................................................... 18
Installation Notice
Installation drawing ......................................................................................... 20
Installation prepare.......................................................................................... 21
Installation
Installation of indoor unit................................................................................ 24
Check after installation ................................................................................... 29
Test operation................................................................................................... 30
Content
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact
the retailer where the product was purchased. They can take this product for
environmental safe recycling.
If it needs to install, move or maintain the air conditioner, please contact dealer or local
service center to conduct it at rst. Air conditioner must be installed, moved or maintained
by appointed unit. Otherwise, it may cause serious damage or personal injury or death.
R32:675

1
Precautions
Please read this operating manual carefully before operating the unit.
Appliance lled with ammable gas R32.
Before use the appliance, read the owner's manual rst.
Befoer install the appliance, read the installation manual rst.
Befoer repair the appliance, read the service manual rst.
The gures in this manual may be different with the material objects, please refer to the
material objects for reference.
To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
The used refrigerant is the uoride R32, which is specially cleaned. The refrigerant is
ammable and inodorous. Furthermore, it can leads to explosion under certain condition.
But the ammability of the refrigerant is very low. It can be ignited only by re.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the
ozonosphere. The inuence upon the greenhouse effect is also lower. R32 has got very
good thermodynamic features which lead to a really high energy efciency. The units
therefore need a less lling.
The Refrigerant
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nearest
authorized Service Center.
Any repairs carried out by unqualied personnel may be dangerous.
The appliance shall be stored in a room without continuously operating ignition sources.
(For example: open ames, an operating gas appliance or an operating electric heater.)
Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a oor area larger than
“X”m2 (see table 1). (only applies to appliances that are not xed appliances)
Appliance lled with ammable gas R32. For repairs, strictly follow manufacturer's
instructions only.
Be aware that refrigerants not contain odour.
Read specialist’s manual.

2
This appliance can be used by children aged of 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause re hazard.
Do disconnect power supply when cleaning air conditioner.
Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in
order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric
shock.
Do not spray water on indoor unit. It may cause electric shock
or malfunction.
After removing the lter, do not touch ns to avoid injury.
Do not use re or hair dryer to dry the lter to avoid deformation
or re hazard.
Maintenance must be performed by qualied professionals.
Otherwise, it may cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric
shock or damage. Please contact dealer when you need to
repair air conditioner.
Do not extend ngers or objects into air inlet or air outlet. It may
cause personal injury or damage.
Precautions
Operation and Maintenance
WARNING

3
Attachment
Installation must be performed by qualied professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing the
unit.
According to the local safety regulations, use qualied power
supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation of
at least 3mm in all poles should be connected in xed wiring.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air conditioner
and disconnect power immediately, and then contact the dealer
or qualied professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions, it
may cause malfunction, electric shock or re hazard.
When turning on or turning off the unit by emergency operation
switch, please press this switch with an insulating object other
than metal.
Precautions WARNING

4
Including an circuit break with suitable capacity, please note the
following table.Air switch should be included magnet buckle
and heating buckle function, it can protect the circuit-short and
overload.
Don't use unqualied power cord.
Make sure the power supply matches with the requirement of
air conditioner.Unstable power supply or incorrect wiring or
malfunction. Please install proper power supply cables before
using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire
of power socket.
Be sure to cut off the power supply before proceeding any work
related to electricity and safety.
Do not put through the power before nishing installation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in
order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep
the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national
wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel only.
The air conditioner is the rst class electric appliance. It must
be properly grounding with specialized grounding device
by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire,
which can't be used for other purposes.
The grounding resistance should comply with national electric
safety regulations.
Precautions WARNING

5
Working temperature range
NOTE:
The operating temperature range (outdoor temperature) for cooling is 18°C ~43°C ; Heating
temperature range for the model without electric heating belt for chassis is -15°C ~ 24°C ;
Heating temperature range for the model with electric heating belt for chassis is
-20°C ~24°C .
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected
by a professional.
If the length of power connection wire is insufcient, please
contact the supplier for a new one. Avoid extending the wire by
yourself.
For the air conditioner with plug, the plug should be reachable
after nishing installation.
For the air conditioner without plug, an circuit break must be
installed in the line.
If you need to relocate the air conditioner to another place, only
the qualied person can perform the work. Otherwise, it may
cause personal injury or damage.
Select a location which is out of reach for children and far away
from animals or plants.If it is unavoidable, please add the fence
for safety purpose.
The indoor unit should be installed close to the wall.
Precautions WARNING

6
Parts name
Panel
Horizontal louver Aux.button
Air inlet
Filter Air outlet
Indoor unit
Remote controller
Actual product may be different from above graphics,please refer to actual products.
NOTE:
Display
Temp.indicator
Temp.indicator
Wi-Fi indicator
Wi-Fi indicator
)$1
6:,1*
02'(
785%2
7,0(5
+($/7+
6/((3
/,*+7
(&2
For some model:
For some model:

7
● During operation, point the remote control signal sender at the receiving window on indoor unit.
● The distance between signal sender and receiving window should be no more than 8m, and there
should be no obstacles between them.
● Signal may be interfered easily in the room where there is uorescent lamp or wireless telephone;
remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
NOTE:
Operation guide
1. Press the back side of remote controller marked
with " ", as shown in the g, and then push out
the cover of battery box along the arrow direction.
2. Installation two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar are
correct.
3. Reinstall the cover of battery box.
Installation batteries
Operation guide
1. After connecting the power, press " " button on remote controller to turn on the air
conditioner.
2. Press "MODE" button to select your required mode: Auto, Cool, Dry, Fan, Heat.
3. Press " " or " " button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press "FAN" button to set your required fan speed: auto , quiet , fan1, fan2 , fan3 , fan4 ,
fan5 , stepless speed.
5. Press "SWING" button to turn on or turn off the swing function.
ὐ
ὑὒ

8
Remote controller
)$1
6:,1*
02'(
785%2
7,0(5
+($/7+
6/((3
/,*+7
(&2
Turbo function
Quiet function
Set fan speed
Child lock
Sleep function
Swing function
Light
Dual-8 nixietube
Auto mode
Cooling mode
Dry mode
Fan mode
Heating mode
Health function
ECO function
Clock display
SWING button
TURBO button
TIMER button
HEALTH button
button
button
ON/OFF button
SLEEP button
FAN button
MODE button
ECO button
LIGHT button
Battery
I feel function
Smart function
There is no this function for
the unit.
This manual suits for next models
3
Table of contents
Other Fluo Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual