Effitherm AWT9-V5+ User manual

Air/water/tank 9/11/13kw Split Heat Pump

Catalogue
1.Before use
1.
2. Safety precautions
3.
4.
5.
6. Specifications
7.
List of accessories
Main components
Outlines and dimensions
Working principles
Exploded view
4
5
8
10
14
14
17
2.Installation
1.
2. Installation of the indoor unit
3. Installation of the outdoor unit
4. Refrigerant pipe connection
Quick connector
Flare nut
5. Water pipe connection
.
7. Air purging of water system
8. Pre-Start up
Installation methods
6 Installation of the accessories
FOUR-way safety valve kit
L type decorative panel in back side
Pipings for mixture valve
9. Power supply and electric connections
22
31
32
34
36
37
39
40
40
41
41
42
44
45
4
22
3.Use
1. Introduction of wired controller
3. Basic operation
4. Advanced setting
5. Failure code
6.
2. Parameter setting overview
Error code
7. Electric heating
46
46
48
53
65
75
76
81
1
02

4.Service and maintenance
1. Attention
.
3. Maintenance
2 Service
Indoor unit
Outdoor unit
Cleaning of water filter
Cleaning of heat exchanger
Gas charging
Cleaning of plate exchanger
Antifreeze in winter
4. Troubleshooting
83
5.Wiring diagram 89
83
84
84
84
86
86
86
86
87
87
87
Catalogue
1
03

The accessories below are delivered together with the product .
Please check in time. If there is any shortage or damage, please contact local distributor.
【Indoor unit】
【 】List of accessories
11. List of accessories
Before use
1
04
User manual
Four-way Safety valve kit
Pressure release valve
Piping for mixture valve
Quantity
1pcs
1set
1pcs
1set
1pcs
2pcs
1pcs
L type decorative panel in
back side 2
Thermostat mixing valve
L type decorative panel in
back side 1
Attention
Dear Customer
Congratulation with your choice of heat pump. You have chosen a high quality product with
some of the latest technology within the heat pump market. This unit, will correctly installed
and set, provide you with cost efficient high level of comfort in your house regarding cooling,
heating and hot shower water.
Install and service the product with authorized and trained personnel only. Do not attend to do
the installation yourself, since the warranty of the product will not be valid. Please read this
manual carefully and make sure you follow the service and maintenance program to ensure
best lifetime and economy of the product. The longer the lifetime, the better investment.

CautionWarning Prohibition
which concerns the product and your personal safety.
The following symbols are very important. Please be sure to understand their meaning,
【 】Symbol description
The installation, dismantlement and maintenance of the unit must be performed
by qualified personnel. It is forbidden to do any changes to the structure of the
unit. Otherwise injury of person or unit damage might happen.
【 】Safety precautions
Make sure the power supply to the heat pump unit is off before any operations are
done on the unit. When the power cord gets loose or is damaged, always get a
qualified person to fix it.
12. Safety precautions
Before use
1
05
User Manua l
Be sure to read this manual before
use.
Keep the unit away from the
combustible or corrosive environment.
Before taking shower, please always
add a mixture valve before water tap
and set it to proper temperature.
This appliance can be used by children aged from 8 yearsand above and persons
with reduced physical, sensory or mental capabilities or lack of experienceand
knowledge if they have been given supervisionor instruction concerninguse of the
appliance in asafeway and understand the hazards involved. Childrenshall not play
with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
1.The heat pump is for “Closed pressurized water borne systems only, with
running pressure from 1-2,5 bars”.
2. Heat pump indoor unit should only be placed in a room with drainage in the floor.
(If any catastrophic leak from the water tank, no costly damage to the house can be
put on ES).

Water tank
12. Safety precautions
Before use
1
06
Ground wire
Use a dedicated socket for this
unit,otherwise malfunction may
occur.
The power supply to the unit must
be grounded.
Don't run the heat pump unit
with water temperature lower
than 25℃.
Do not touch the power plug with
wet hands.Never pull out the pulg
by pulling the power cable.
Water or any kind of liquid is strictly
forbidden to be poured into the
product, or may cause creepage or
breakdown of the product.
When running the unit, never cover
the product with clothes, plastic
cloth or any other material that
block ventilation on the product,
which will lead to low efficiency or
even non-operation of this unit.
Main
Power Cable RCD
Indoor
unit
It is mandatory to use a suitable circuit
breaker for the heat pump and make
sure the power supply to the heater
corresponds to the specifications.
Otherwise the unit might be damaged.
Disposal of Scrap Batteries ---
Please discard the batteries as sorted
municipal waste at the accessible
collection point.
Installation of a residual current device
(RCD) having a rated residual
operating current not exceeding
30 mA is advisable.
ON
OFF
City water inlet
Connect to water tank
Min. 0.1 Mpa
Max. 0.7 Mpa
The maximum inlet water pressure, in pascals: 0.7Mpa.
The minimum inlet water pressure, in pascals, if this is necessary for the correct operation of the appliance: 0.1Mpa.

Sanitary hot
water
12. Safety precautions
Before use
1
07
Be aware finger might be hurt by the fin of the coil.
Copper
Steel Fuse
Please select the correct fuse or breaker as per recommended. Steel wire or
copper wire cannot be taken as substitute for fuse or breaker. Otherwise,
damaged maybe caused.
When the power cord gets loose or is damaged, always get a qualified person to
fix it.
Do not touch the air outlet grill when fan motor is running.
Please mind that when the unit works under room temperature control mode, it
may not supply sanitary hot water with enough high temperature.

【 】 Indoor unit
Inside
Top
Outside
13. Main components
Before use
1
08
35
36
37
38
AWT9/11-V5+
Handle
Wired controller
Decorative panel
Front panel
Digital thermostat
Automatic air purging valve
T/P valve
Water pressure gauge
Four-way safety valve kit
L type decorative panel in back side 1
L type decorative panel in back side 2
Middle temperature hot water outlet
Filling water to coil
Filling water to water tank
High temperature hot water outlet
Refrigerant connector(3/8’’~½’’)
Fixing plate for refrigerant connector
Cable gland
Water from heating/cooling system(G1’’male)
(G1’’male)
(G1’’male)
(G3/4’’male)
(G1’’male)
Water to heating/cooling system
Water expansion tank
Refrigerant expansion tank
Emergency Switch for 6KW electric heater
Thermostat knob
Plate heat exchanger
Water pump
Drainage
Electric box
Overheating protector for 1.5KW electric heater
Temperature sensor for 1.5KW electric heater
1.5KW electric heater 230V/50Hz/1Ph
Water flow switch
6KW electric heater 400V/50Hz/1Ph
Anode Rod
Temperature sensor for hot water mode
Motorized three-way valve
Water tank
Rubber absorber feet
(G1’’male)

【 】 Indoor unit
Inside
Top
Outside
13. Main components
Before use
1
09
35
36
37
AWT13-V5+
Handle
Wired controller
Decorative panel
Front panel
Digital thermostat
Automatic air purging valve
T/P valve
Water pressure gauge
Four-way safety valve kit
L type decorative panel in back side 1
L type decorative panel in back side 2
Middle temperature hot water outlet
Filling water to coil
Filling water to water tank
High temperature hot water outlet
Refrigerant connector
Fixing plate for refrigerant connector
Cable gland
Water from heating/cooling system
(G1’’male)
(G1’’male)
(G3/4’’male)
(G1’’male)
(3/8’’~5/8’’)
(G1’’male)
Water to heating/cooling system
Water expansion tank
Emergency Switch for 6KW electric heater
Thermostat knob
Plate heat exchanger
Water pump
Drainage
Electric box
Overheating protector for 1.5KW electric heater
Temperature sensor for 1.5KW electric heater
1.5KW electric heater 230V/50Hz/1Ph
Water flow switch
6KW electric heater 400V/50Hz/1Ph
Anode Rod
Temperature sensor for hot water mode
Motorized three-way valve
Water tank
Rubber absorber feet
(G1’’male)

【 】 Indoor unit
14. Outlines and dimensions
Before use
Unit:mm
1
10
AWT9/11/13-V5+
This manual suits for next models
5
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual











