Dome DMS01 User manual

Always Connected. Always Covered.
Siren
User Manual
DMS01

Page 2
Siren Advanced User Manual
Preface
As this is the full User Manual, a working knowledge of Z-Wave automation
terminology and concepts will be assumed. If you are a basic user, please visit
www.domeha.com for instructions. This manual will provide in-depth techni-
cal information about the Siren, especially in regards to its compliance to the
Z-Wave standard (such as compatible Command Classes, Association Group ca-
pabilities, special features, and other information) that will help you maximize
the utility of this product in your system.
Preface

Page 3
Siren Advanced User Manual
Table of Contents
Table of Contents
Preface................................................................................................................................. 2
Description & Features..................................................................................................... 4
Specifications..................................................................................................................... 5
Physical Characteristics ................................................................................................... 6
Inclusion & Exclusion........................................................................................................ 7
Factory Reset & Misc. Functions..................................................................................... 8
Physical Installation.......................................................................................................... 9
LED Behavior .................................................................................................................... 10
Compatible Command Classes..................................................................................... 11
Configuration Parameters ............................................................................................. 13
Troubleshooting.............................................................................................................. 15
Warranty & Support ........................................................................................................ 16

Page 4
Siren Advanced User Manual
Description & Features
The Dome Siren is a battery powered Z-Wave Plus device that alerts the user
to events detected by the connected Z-Wave Controller using an audible alarm.
In addition to a DECIBEL dB audible alarm for critical events, the Siren has a
secondary chime to signal other events like movement or doors opening,
Key Features:
»Z-Wave Plus Certified
»DECIBEL dB Audible Alarm
»Visual indicator with built-in LED ring
»Secondary Chime
»Customizable notifications and volume levels
»Up to 150’ range
»Three-Year Battery Life
»Low Battery Indication
Description & Features

Page 5
Siren Advanced User Manual
Specications
Package Contents:
Technical Specications
Radio protocol Z-Wave(500 series)
Power supply 2x CR123 3.0V battery
Power Consumption 2W
Working current 35mA
Operating temperature 32—104 °F (0—40 °C)
Radio frequency 908.4 MHz US
Range Up to 150’ depending on environment
Dimensions (L x W x H) Ø2.75” x 1.2”
Table 1 - Technical Specications
User Manual Siren 2x Battery 1x Screw 1x Wall Anchor
SolidWorks Student Edition.
For Academic Use Only.
Specications

Page 6
Siren Advanced User Manual
Physical Characteristics
SolidWorks Student Edition.
For Academic Use Only.
SPEAKER
CONNECT BUTTON
LED RING
A. B.
Figure 2 - Showing individual parts A. Inside the Siren and B. Underneath the Siren.
SolidWorks Student Edition.
For Academic Use Only.
BACK COVER
MAIN BODY
BATTERIES
BATTERY TABS
Figure 1 - Exploded View
Physical Characteristics

Page 7
Siren Advanced User Manual
Inclusion & Exclusion
Inclusion
Follow the instructions for your Z-Wave Certified Conto enter inclusion mode.
When prompted by the controller:
1. The Siren should be within 10’ of your Z-Wave controller for the inclusion
process. After successful pairing, the device can be brought to the desired lo-
cation.
2. Remove the BACK COVER by twisting it CLOCKWISE.
3. Remove the BATTERY TABS.
4. Press the CONNECT BUTTON quickly 3 times in a row.
The LED RING will flash five times indicating exclusion/disconnection.
Exclusion
Follow the instructions for your Z-Wave Certified Conto enter exclusion mode.
When prompted by the controller:
1. Remove the BACK COVER from the MAIN BODY.
2. Press the CONNECT BUTTON quickly 3 times in a row.
The LED RING will flash five times indicating exclusion/disconnection.
Inclusion & Exclusion

Page 8
Siren Advanced User Manual
Factory Reset & Misc. Functions
Resetting the Siren
If needed, the Siren can be reset locally by following these steps. Only do this
when your Z-Wave controller is disconnected or otherwise unreachable. Beware
that resetting your device will disconnect it from the system:
1. Remove the BACK COVER and confirm that your Siren is powered up.
2. Press and hold the CONNECT BUTTON for at least 10 seconds then release.
A flashing light indicates a successful factory reset.
3. The Siren’s memory will be erased to factory settings.
Waking Up The Siren
Because the Siren is a battery powered device, it wakes up on regular intervals
to give battery and other status updates to the controller, as well as to accept
configuration settings from the controller. This helps to extend the battery life.
The device can be forced to wake up to submit these reports or accept new set-
tings immediately by simply pressing and holding the CONNECT BUTTON for two
seconds. The LED RING will flash once indicating successful wake up.
Factory Reset & Misc. Functions

Page 9
Siren Advanced User Manual
Physical Installation
The device should already be included in your Z-Wave system before continuing
further. Study the Pre-Installation Checklist below for a broad overview of in-
stallation options and other notes to bear in mind .
Pre-Installation Checklist
9The Siren can be mounted on a wall or placed on shelf or tabletop
9The Siren is loud enough to be audible from inside a drawer
9The BACK COVER twists CLOCKWISE to be removed
9The Siren should be included in your Z-Wave System prior to installation
9Confirm that your device can communicate with your Z-Wave Controller
from the final installed location before proceeding
Installation—With Double-Stick Tape
1. Wipe the surface you wish to attach the Siren to clean of any residue.
2. With the Siren completely assembled, peel the preapplied adhesive backing
and firmly push it against the wall.
Installation—Using Keyhole Slot
1. Drive a screw into the surface the Siren will be attached to, leaving it 1/8”
away from being completely flush.
2. Slide the fully assembled Siren around the screw, into the keyhole slot, and
pull it down to completely secure the device around the screw.
Installation—With Screws
1. Remove the BACK COVER by twisting it clockwise.
2. Hold the BACK COVER on the surface it will be attached to, and drive two of
the included screws through indentations on the BACK COVER. You may option-
ally install anchors in the wall for added support.
3. Twist the MAIN BODY counter clockwise onto the BACK COVER.
Physical Installation

Page 10
Siren Advanced User Manual
LED Behavior
Color Behavior This happens when…
Red
Blink 5 times in 1 second …the device powers on, but is not yet included in a
Z-Wave Network.
Blink 5 times in 500ms
…the CONNECT BUTTON is pushed 3 times, either
resulting in the Siren sending its NodeInfo, or being
included or excluded from a Z-Wave network.
Blink 5 times in 300ms …the device powers on, and is arleady included in
a Z-wave network.
Blink Once
…the CONNECT BUTTON is pressed for an extended
period of time, resetting the Siren to factory default
settings.
Flashing and Spinning …the Siren is sounding its alarm.
Table 2 - LED Blinking Behavior
LED Behavior
Table of contents
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual