931022A
PCM
TIM
POWER
TONE
VOLUME
BGM SRC
VOLUME
GND ST
IN
RT
BGM
SRC
NIGHT
RING
TEL
LINE
OVER
RIDE
NC
COM
NO
NC
COM
NO
RLY
ONE
RLY
TWO
S1
S2
S3
S4
S5
S6
S7
TEL
INT
SEL
0 1
S1
S2
S3
S4
S5
S6
S7
TEL
INT
SEL
0 1
1 - Not used
2 - Contact Closure
3 - Dry audio (R)
4 - Dry audio (T)
5 - Contact Closure
6 - Not used
Bogen PCM2000 Zone Paging System with Old PCMTIM to Singlewire Paging Adapter Connections—Contact Closure Configuration
Bogen PCMTIM Module Configuration Singlewire Paging Adapter Connections
+-+
-
Notes
CyberData Singlewire Paging Adapter's Page Port output connects to the
TEL LINE input on the PCMTIM module using an RJ11 modular connec-
tor. Pins 2, 3, 4, and 5 of the RJ11 modular connector will be used for this
configuration.
Power off the PCMTIM. Set the TEL INT SEL switches per the above dia-
gram for a Page Port/Contact Closure configuration. Page activation
occurs upon contact closure.
It will be necessary to use the dry relay contacts for contact closure. Be
sure to check the Enable relay on local audio option on the Device
Configuration page of the web interface.
s
Page Port Output Connections
Pin Description
1 Fault Sense Input (Common).
2 Fault Sense Input (Sense).
3 Positive 600-Ohm Audio Outputa
a.The 600-Ohm audio output of the page port is
also suited for interfaces with lower input
impedances.
4 Negative 600-Ohm Audio Outputa
5 Audio Ground Reference.
6 Relay Contact - Commonb
b.1 Amp at 30 VDC for continuous loads.
7 Relay Contact - Normally Openb
TEL LINE