Coolix MPM3-10CRN1 User manual

MPM3-10CRN1 / MPM3-12CRN1
DE
EN
IT
FR
NL
KLIMATYZATOR PRZENOŚNY
DK
SE
NO
FI
PL

INFORMATION
SAFETY INSTRUCTIONS 28
DESCRIPTION OF APPLIANCE 30
ACCESSORIES 32
CONTROL PANEL 33
OPERATING THE APPLIANCE 34
INSTALLATION AND START-UP 38
OPERATING INSTRUCTIONS 40
WATER DISCHARGE 41
MOUNTING 43
CLEANING, MAINTENANCE AND STORAGE 45
TROUBLESHOOTING 46
WEEE 48
INSTRUCTIONS FOR USE
PURCHASE TERMS AND CONDITIONS 48
WARRANTY 49

28
CAUTION
deAr CuStOMer,
Thank you for buying a product that was developed and tested to meet even the highest demands. Please read the instruc-
tions for use carefully before the first start up, so that you may get to know all the functions of this appliance. Keep the
instructions for use nearby for reference whenever required.
InFOrMAtIOn
In summer, one feels good at a temperature between 24°C and 27°C, and a relative humidity of about 50%. Air-conditioners
serve the purpose of recreating this condition even at higher external temperatures and higher humidity levels in the room
by removing humidity and heat from the air in the room.
Unlike permanently installed air-conditioners, mobile models have the advantage that they can be moved from one room
to another and can be transported to another building.
SAFetY InStruCtIOnS
1. Do not operate this appliance if it is damaged or has damages, or if it does not function properly. Disconnect the power
plug from the power outlet.
2. Install the appliance at a place where children cannot reach it.
3. Do not use the appliance:
A. In the vicinity of heat sources, e.g., heater or a heating appliance, clothes dryer, etc.
B: At places where oil and water can be splashed.
C. At places that are directly exposed to sunlight.
D. In the vicinity of bathtubs, showers or swimming pools.
E. In a greenhouse.
F. In the vicinity of easily flammable gases and substances.
G. Behind curtains or other objects or obstacles that can have an adverse effect on the air circulation.
H. In the open.
4. Always place the appliance in the upright position, so that the compressor can function properly.

EN
29
5. If the power cord of the appliance is damaged, it must be repaired by a repair shop authorised by the manufacturer
because special tools are required.
6. Always unplug the power plug from the power outlet when the appliance is not in use, or when it is moved, touched
or cleaned. Do not pull on the cord to disconnect the power plug.
7. Always switch the appliance off before disconnecting the power plug from the power outlet by activating the POWER
button on the operating panel.
8. Do not remove the water tank when the appliance is in operation.
9. Never insert your finger or other external bodies into the screen or openings.This can lead to overheating, fire or electric
shock. Warn children about these dangers.
10. Do not submerge the appliance in water or other liquids and do not spill water or other liquids onto the appliance or into
the air intake and air outlet openings.
11. The appliance must be cleaned regularly. Please observe the cleaning instructions in this context. Disconnect the appli-
ance from the power supply before cleaning.
12. The appliance should not be covered.
13. Do not use insecticide sprays or other sprays on the appliance that can cause a fire.
14. The appliance does not contain components that require maintenance by the user. You must send the appliance
to the manufacturer or to Customer Service, if the appliance or the power cord is damaged.
15. Please empty the water tank before transporting the appliance. The appliance must first be disconnected from
the power supply.
16. The appliance is not suitable for cooling server rooms.

30
DESCRIPTION OF APPLIANCE
1. Operation panel
2 Horizontal ventilation flap
3 Signal receiver of remote control
4 Air intake
5 Handle on both sides
6 Air intake opening
7 Power cable and power plug
8 Opening for the drainage hose
9 Air intake opening
10 Hot air outlet
11 Air intake opening
1
2
3
4
5
7
8
9
10
11
6

EN
31
Horizontal ventilation flap
In addition to the electronic movement of the ventilation flaps, you have the additional option of adjusting the ventilation
flaps manually by freely selecting an angle up to 45°.
1 Pull the flaps up and bring them into the desired position.
1

32
Check whether all the accessories
are included in the packaging and read
the instructions for use to learn how
these are to be used.
ACCESSORIES
Figure Designation Number
Exhaust cable 1
Adapter A (for permanent cable mounting) 1
Adapter B (for temporary cable mounting) 1
Expansion plug 4
Tape for fastening power cable 2
Drainage hose 1
Window panel set 1
Foam seal 3
Remote control 1
E
TMP
U
AOT
OC OL
RD Y
EH TA
A
F N
IH GH
M DE
OL W
MO E
D
AF NP
SEE D
WS NI G
IT MRE O N
CE OON MY
O /N O FF
IT M RE O
FF
E
RES TOL KC
E
S T ET M E
PAR U
TE
R ( C
)
F L
O O
LW
ME L D
E
D SI LP YA
O
IN
UT B
RO

EN
33
OPERATION PANEL
Familiarise yourself with the control panel and the remote control and all the functions before operating the appliance.
Follow the symbol for the desired function. The appliance can be operated from the control panel of the appliance or
with the remote control.
1 Activates the timer
2 Mode control light
3 Turbo mode
4 Set mode
5 Clean Air mode (in some models)
6 Sleep Mode
7 Switches device on or off
8 Sets blower speed
9 Control light of blower speed
10 Direction regulation
11 Sets temperature or time
LED display window: Displays the set temperature, auto timer and fault code.
1
2
3 4 678
9
10
1111
5

34
OPERATING THE APPLIANCE
2 Changing the temperature
Press or hold the or key down till the desired temperature appears on the display. Please choose a temperature
between 17°C and 30°C. If the display should show the current room temperature, see Section 4. The temperature may be
displayed in degrees Fahrenheit or degrees Celsius. To switch from one unit to the other, hold the and keys down
simultaneously for 3 seconds.
2
2
3
3 Blower speeds
By pressing this key you can select one of the following four blower speed levels: slow , medium , fast or auto
(there is no control light for Auto). The speed changes each time you press the key.
1
1 Switching the appliance on/off
1

EN
35
4 Modes
Press the MODE key to select the desired mode. Pressing the button again will switch the operating modes in the follow-
ing sequence: auto , cool , dehumidify , fan . You can view the mode you have selected with the help of the con-
trol light. The blower speed cannot be set in the mode. The speed is adjusted automatically to the room temperature. If
the room is relatively cool, the blower runs only at a lower level. Cooling is not possible in the mode, it is meant only for
air circulation in the room. Instead of the desired temperature, the display shows the actual room temperature in this mode.
Needless to mention, the blower speed can be adjusted.
4
5
5 Sleep function
The selected temperature is increased by 1°C after 30 minutes on pressing this key. The temperature is increased by 1°C
again after another 30 minutes. The new temperature is maintained for 7 hours, the appliance is then reset to the original
temperature, the Sleep mode ends and the appliance resumes working as programmed earlier . The Sleep mode
program can be deactivated at any time when the appliance is in operation by pressing the key again or by switching
the appliance off or by pressing the or key.This function is not available in the or mode.
This manual suits for next models
1
Table of contents
Other Coolix Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual