CEStronics WT-I Manual

OMEGA FLEX wall terminals
WT-I/WT-II
Fitting and Operating
Instructions
Translated fitting and
operating instructions
version 1.2, 03/2013

Contents
Page 2 of 80 OMEGA FLEX wall terminals WT-I/WT-II
1Contents
2Notes on the layout ................................................ 4
3Preface ................................................................... 5
3.1 Versions ........................................................... 5
3.2 Manufacturer and Service ................................... 5
3.3 Target group ..................................................... 6
4For your safety .................................................. 7
4.1 Explanation of the safety notes............................ 7
4.2 Intended use..................................................... 8
4.3 CE Declaration of Conformity............................... 9
4.4 Basic safety instructions ................................... 10
5Introduction ......................................................... 13
5.1 Description...................................................... 13
5.2 Scope of delivery ............................................. 17
5.3 System components ......................................... 19
5.4 Versions and their functions .............................. 20
5.5 Programming with OMEGA software ................... 21
5.6 Optional Master media...................................... 23
6Fitting the wall terminal ....................................... 26
6.1 Connections WT-I ............................................ 28
6.2 Connections WT-II ........................................... 31
7Operating the wall terminal .................................. 44
7.1 Mifare locking media ........................................ 44
7.2 DESFire EV1 Transponder (locking media)........... 45
8Programming via programming cable ................... 47
9Programming with the RF-Stick ............................ 52
10 Maintenance ......................................................... 56
11 Care ...................................................................... 56

Contents
OMEGA FLEX wall terminals WT-I/WT-II Page 3 of 80
12 Spare Parts .......................................................... 56
13 Trouble-shooting.................................................. 57
14 Disposal ............................................................... 58
15 Technical data ...................................................... 59
15.1 WT-I/WT-II (CES standard) ...............................59
15.2 WT-I/WT-II (Flush installation) .......................... 60
15.3 Appropriate power supply..................................62
15.4 WT-I/WT-II, Siedle BM-611 housing (optional)....62
15.5 WT-I/WT-II, IP 55, surface installation (optional) .63
15.6 WT-I/WT-II, IP 55, Flush installation (optional) ...63
16 Glossary ............................................................... 64
17 Overview of the signals ........................................ 65
18 Concise Programming Guide ................................ 68
18.1 Defining the SYSTEM-MASTER............................68
18.2 Authorizing a PROGRAM-MASTER .......................69
18.3 Authorizing a locking medium ............................70
18.4 Enabling RF mode (RF-INI-MASTER) ..................71
18.5 Enabling and disabling RF mode .........................71
18.6 No RF link established.......................................71
18.7 Programming with RF-Stick ...............................72
18.8 Authorizing optional media ................................73
18.9 Deleting the authorization of a PROGRAM-
MASTER ..........................................................74
18.10 Deleting the authorization of a locking medium ...75
18.11 Deleting the authorizations of all locking media ...76
19 Notes on the manufacturer's warranty................. 77
20 Index ................................................................... 78

Notes on the layout
Page 4 of 80 OMEGA FLEX wall terminals WT-I/WT-II
2Notes on the layout
In these Fitting and Operating Instructions, various elements are
highlighted with defined layout features:
Additional information on the efficient use of the
OMEGA FLEX wall terminal
Reference to additional information
Notes on the correct disposal
Steps in a sequence of actions. Tips with this
symbol require you to perform an action

Preface
OMEGA FLEX wall terminals WT-I/WT-II Page 5 of 80
3Preface
These Fitting and Operating Instructions will help you fit and use
the OMEGA FLEX wall terminals WT-I/WT-II (the "wall terminal")
as intended, safely and advantageously.
Any person who programs, operates or disposes of this wall
terminal must have read and understood the entire contents of
these Fitting and Operating Instructions.
These Fitting and Operating Instructions should be kept within
reach at all times as long as the wall terminal is used.
These Fitting and Operating Instructions should be handed over to
the end users.
Be sure to use the most recent version of these Fitting
and Operating Instructions. Updated versions are
available free of charge at www.ces.eu.
3.1 Versions
These Fitting and Operating Instructions only apply to:
CEStronics OMEGA FLEX wall terminals WT-I/WT-II,
in all variants
3.2 Manufacturer and Service
The manufacturer of the wall terminal is:
CEStronicsGmbH
Friedrichstr. 243
42551 Velbert
Tel: +49 (0) 2051-204-0
Fax: +49 (0) 2051-204-105
www.ces.eu
For service support please contact your professional CEStronics
partner.

Preface
Page 6 of 80 OMEGA FLEX wall terminals WT-I/WT-II
3.3 Target group
These Fitting and Operating Instructions are intended for trained
fitting staff, maintenance staff and operators.
As regards the use of these Operating Instructions, it is assumed
that the necessary technical knowledge on how to use the product
as intended is available.
The necessary product training is provided by your professional
CEStronics partner. If this has not yet taken place, please contact
your professional CEStronics partner to obtain training on the
product.
NOTICE
Unintended condition of your system
possible!
If you are not fully familiar with the various
possibilities of your system, it may perform
unexpected functions.
If you program the OMEGA FLEX system, you
must be clearly aware of the consequences of
your programming to prevent undesired
results.
If there are functions of the OMEGA FLEX
system you do not understand, contact your
professional CEStronics partner to obtain
further information.
Always satisfy yourself that your programming
produces the desired result.

For your safety
OMEGA FLEX wall terminals WT-I/WT-II Page 7 of 80
4For your safety
4.1 Explanation of the safety notes
These Fitting and Operating Instructions include safety notes of
the following types:
NOTICE
These notes warn against possible property
or environmental damage.
CAUTION
CAUTION notes warn against hazards that
may result in slight or medium injuries.
WARNING
WARNING notes warn against hazards that
may result in medium to fatal injuries.

For your safety
Page 8 of 80 OMEGA FLEX wall terminals WT-I/WT-II
4.2 Intended use
The wall terminals serve to control door opening mechanisms
(actuators). The wall terminals are exclusively intended and may
only be used for that purpose.
Any other use is considered to be improper and may result in
property damage or even personal injury.
CEStronics GmbH does not accept any liability for any damage
resulting from improper use.

For your safety
OMEGA FLEX wall terminals WT-I/WT-II Page 9 of 80
4.3 CE Declaration of Conformity

For your safety
Page 10 of 80 OMEGA FLEX wall terminals WT-I/WT-II
4.4 Basic safety instructions
Observe all warnings and notes in these Fitting and Operating
Instructions when fitting, programming and using the wall
terminals.
To prevent danger to life and limb, the following safety
instructions must be observed:
4.4.1 Danger to life
People may not be able to open the door in emergencies and
may be injured or killed. Do not use the wall terminal e.g. for
doors with anti-panic function, such as escape doors.
The wall terminal must be suitable for your door system. In
case of doubt, please contact the manufacturer of the door or
the door lock and satisfy yourself that the wall terminal is
suitable for your door system.
4.4.2 Danger of explosion
Live parts of the wall terminals may cause an explosion. Do not
use the wall terminals in potentially explosive atmospheres.
4.4.3 Danger of suffocation
Never allow children to play with packaging material and/or plastic
bags. There is a risk that children pull them over their head and
suffocate. Keep film and other packaging materials out of the
reach of children.
This manual suits for next models
1
Table of contents
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual











