I. Notes................................................................................................. 3
II. Featuresand Components......................................................... 4
III. Installation and Adjustment.......................................................6
IV. Control Setting.............................................................. .…... . 8
V. Drainage Instructions....................................................................... 10
VI. Maintenance………………………………………………… 11
VII. Troubleshooting............................................................................ 12
VIII. Appendix................................................................................. 13

Page: 3/14
Thank you for choosing the luxurious and elegant mobile air conditioning. Please
keep the manual for later review, and read the manual carefully before use.
I. Notes
Notes:
*The air conditioning is only suitable for indoor use, and is not suitable for other applications.
* Follow local grid interconnection rules while installing the air conditioning and ensure that it is
properly grounded. If you have any question on electrical installation, follow the instructions of
the manufacturer, and if necessary, ask a professional electrician to install it.
* Place the machine in a flat and dry place and keep a distance of above 50cm between the
machine and the surrounding objects or walls.
*After the air conditioning is installed, ensure that the power plug is intact and firmly plugged
into the power outlet, and place the power cord orderly to prevent someone from being tripped or
pulling out the plug.
*Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and
outlet free from obstructions.
* When drainage pipes are installed, ensure that the drainage pipes are properly connected, and
are not distorted or bended.
* While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands
gently to avoid damaging wind-guide strips.
*When moving the machine, make sure that it is in an upright position.
* The machine should stay away from gasoline, flammable gas, stoves and other heat sources.
* Don't disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a
machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine
failure occurs, ask the manufacturer or professionals to repair it.
*Do not install and use the air conditioning in the bathroom or other humid environments.
* Do not pull the plug to turn off the machine.
* Do not place cups or other objects on the body to prevent water or other liquids from spilling
into the air conditioning.
*Do not use insecticide sprays or other flammable substances near the air conditioning.
* Do not wipe or wash the air conditioning with chemical solvents such as gasoline and alcohol.
When you need to clean the air conditioning, you must disconnect the power supply, and clean it
with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
*The appliance can be used by children aged from 8 years and above and persons with reduced

Page: 4/14
physical, sensory or mental capabilities if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and maintenance shall not be made by children
without supervision.
II. Features and Components
1. Features
•New look, compact structure, streamlined machine, aristocratic atmosphere.
•With cooling, heating (single cold with no such function), dehumidification and air supply
function.
•Automatic swing leaf in the outlet has automatic air swing function, and the outlet can be
covered when the machine is turned off to prevent dust from entering the body.
•LCD displays the control panel. The machine is beautiful and elegant. High-quality LCD
remote control is equipped to facilitate operation. The remote control can be placed on the back
of the body. It adopts a user-friendly remote control storage design.
• Handles on both sides adopt dividing point design, so that it is easer to carry it and the body
design is more humane.
•The structure of wrapping the power cord on the back facilitates users to hang the power cord
without hanging itot dthoewgnround and staining and damaging the power cord.
•Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe.
•Air filtration capability.
• Timing switch function, unique switching machine music.
•Protection function of automatically restarting the compressor after three minutes, a variety of
other protection functions.
•Patented product, patent No.: CN201330444908.8.

1
2
3
4
5
6
7
8


Figure 4
Page: 7/14
2)Elongate the heat pipe and snap the flat end of the heat pipe joints into the elliptical hole
of the window sealing plate assembly (as shown in Figure 5 and Figure 6) .
Notes: 1. the flat end of the heat pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep
the ventilation of the heat pipe unobstructed.
Figure5 Figure 6
Important Notice
The length of the exhaust hose shall be 280~1,500mm, and this length is based on the
specifications of the air conditioning. Do not use extension tubes or replace it with other different
hoses, or this may cause a malfunction. Exhaust must be unobstructed; otherwise it may cause
overheating.

1
Power key
2
Mode selection key
3
Window display
4
Down key
5
Up key
6
Wind speed selection key
7
Timing key


Page: 10/14
8. : press the key to switch between Celsius and Fahrenheit.
III. A Variety of Protection Functions
3.1 Frost Protection Function:
In cooling, dehumidification or economic power saving mode, if the temperature
of the exhaust pipe is too low, the machine will automatically enter protection
status; if the temperature of the exhaust pipe rises to a certain temperature, it can
automatically revert to normal operation.
3.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will
automatically sound an alarm, and the LDC temperature display area will show
"FL". At this point, you need to move the drainage pipe connecting the machine
or the water outlet to sewer or other drainage area to empty the water (details
see Drainage Instructions at the end of this chapter). After the water is emptied,
the machine will automatically return to the original state.
3.3 Automatic Defrosting (heating and cooling models have this function):
The machine has automatic defrosting function: during defrosting, heating symbol
on the display screen will flash.
3.4. Automatic Thermal Protection:
To protect the service life of the machine, the machine has automatic thermal
protection in heating mode. During the protection period, the compressor and the
lower motor will stop operation and will automatically return to normal heating state
after the temperature of the machine recovers.
3.5 Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.
Other manuals for YPS3-14H
1
Table of contents
Other CCH Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual