CAS CI-600D Series User manual

2

Cautions for Your Safety
Please comply with 'Cautions for Your Safety', which will lead you to use the product safely and
properly to prevent any dangerous situations.
■Cautions are divided into 'Warning' and 'Alert', which mean as follows.
■Keep this manual in a place where product users can find out, after finish reading it.
'Warning' means a great possibility led to the death or heavy injury when instructions are violated.
'Alert' means a great possibility led to the injury or material damage when instructions are violated.
3

Warning
Never disassemble, repair or retrofit the
product.
It might exclude the product from the
quality assurance and cause the damage
to devices, electric shock or fire.
Ensure the power plug to be fully
inserted to prevent shaking.
Any instable connection might cause
electric sparks to set fire.
Ensure the grounding of the product.
Poor grounding might cause failure or
electric shock upon electric leak.
Do not damage, process, excessively
jerk, bend or twist the power cord.
It might damage the power cord to
cause fire or electric shock.
Keep any combustible spray or fire
source away.
It might cause fire.
Do not spray water to the outside of the
product or use it in any humid place.
It might deteriorate the insulation of
electric parts that can cause the electric
shock, fire risk or weighing errors.
Do not place the product to the direct
sunlight or near any hot object like
a heater.
It might cause fire.
4

Attention
Check the weighing error anytime for
the accurate weighing.
Any use out of the allowed tolerance
for the careless use or other causes
might not ensure the accurate
weighing.
Customer Service:080-022-0022
Avoid any sudden shock to the product.
It might damage the product to fail the
accurate weighing.
Find a proper place to attach the rubber
pad at the bottom of the indicator,
which was shipped together.
Do not use the product at a place with
sudden temperature changes or severe
vibrations.
It might cause the weighing error or
failure.
Do not install the produce at a place with the excessive electromagnetic wave.
It might cause the wrong weighing.
Our Dealers : CAS feels that each of its valued customers should get the best service
available. Whether it’s the initial installation of our product,
maintenance/repair work, or simply answering questions about our products,
CAS Corporation and all of its Authorized Dealers are highly trained to assist
you with any need regarding CAS products.
5

Contents
1. Features...............................................................................9
1-1. Features........................................................................................ 9
1-2. Main Functions ...........................................................................9
1-3. Digital Loadcell Interface.........................................................10
1-4. Digital and Display ...................................................................10
1-5. General Specifications.............................................................. 11
1-6. Option Specifications................................................................ 11
2. Specifications inAppearance................................................... 12
2-1. External Dimension ..................................................................12
2-2. Front Panel Descriptions ..........................................................12
2-3. Keyboard ...................................................................................14
2-4. Rear Panel Descriptions............................................................17
3. Installation & Connection.........................................................18
3-1. Loadcell Connection.................................................................18
4. DLC Mode.........................................................................................19
4-1. DLC Mode Menu...................................................................... 19
5. Weight Setup(Calibration) Mode.......................................... 26
5-1. Weight Setup(Calibration) Menu ............................................. 26
5-2. How to Seal the Indicator(Sealing)..........................................37
6. Weight Mode.................................................................................... 38
6-1. Zero function ............................................................................. 38
6-2. Tare function..............................................................................39
6-3. Net Weight / Gross Weight Selection....................................... 40
6-4. Item Number Change................................................................41
6-5. Subtotal Print ............................................................................. 41
6-6. Total Print...................................................................................42
6-7. Selection and Change of Article Information.......................... 43
6-8. How to Change Item Number..................................................43
6-9. Change in Tare Weight.............................................................. 44
7. Test Mode........................................................................................... 45
6

8. Set Mode...............................................................................................50
8-1. How to Enter the Set Mode ......................................................50
8-2. General Functions......................................................................53
8-3. Communication and Function Setting .....................................59
8-4. Print Function Setting................................................................64
8-5. Option Setting............................................................................69
8-6. Hardware Set Function..............................................................70
9. RS-232C Interface in Detail.....................................................72
9-1. RS-232C Port Connection ........................................................72
9-2. How to Connect an Auxiliary Display.....................................73
9-3. How to Connect a Label Printer(DLP) ....................................73
9-4. RS-422 & 485 Serial Communications ...................................74
10. Serial Data Information...........................................................75
10-1. CAS 22Bytes Format..............................................................75
10-2. CAS 10Bytes...........................................................................75
10-3. AND 18Bytes ..........................................................................75
10-4. CAS 22Bytes with relay status...............................................76
11.Appendix..........................................................................................77
12. Modbus Protocol..........................................................................80
13. Error Message...............................................................................85
13-1. Error Message from the Weight Setup Mode.............................85
13-2. Error Message from the Weighing Mode...................................86
7

Preface
Thank you very much for purchasing CAS International Indicator.
This produce is characterized by the excellent performance and luxurious features through
strict examinations, as well as elaboration for each part under our strict quality control.
CAS Indicator (CI-series) is a product with rich functions and various external interfaces,
which is designed to comply well with special requirements in a variety of industrial fields
under strong and beautiful designs in appearance.
In addition, it is designed for the user-friendly programs for the easier use of indicator by any
user with the built-in message display functions to help users understand the product.
Please use the product right and sufficiently utilize functions of CI-600 series as you read this
manual thoroughly before using CI-600 series.
8

1. Features
1-1. Features
■High accuracy
■High speed micro processor adoption
■Appropriate for weight and measurement system
■Easy operation and various options.
■Simple and prompt Full Digital Calibration
(SPACTM: Single pass automatic span Calibration)
■RFI./EMI screened
■Watch Dog circuitry (System restoration)
■Weight Back-up
(Weight memory at sudden power failure)
1-2. Main Functions
■Store date, time and calculated data at sudden power failure.
■Various specification on weight conversion speed.
(Digital filter function)
■Various printer connection. (RS-232C Serial printer)
■Tare weight setting with keys.
■Storage of measured times.
■Set Point input & highest, lowest limit input.
■External input 4 relay.(CI-605)
■External output 6 relay.(CI-605)
■Users can set the desirous max. weight and a division freely.
■Control various external equipment by inner external input/output.(option)
■Print date and time by inner clock.
■Self hardware Test.
■Prompt A/S is available for Test of each part of circuit by module is possible.
9

1-3. Digital Loadcell Interface
Applied voltage for load cell DC 9V
Loadcell connection Max. 10EA
Communication RS-485 half-duplex(COM2)
Baudrate 9,600BPS ~ 115,200BPS
Non-straightness 0.01% Full Scale
1-4. Digital and Display
Span Calibration Full Digital Calibration : SPAC™
(Single automatic span Calibration)
Display 4.3” Full Graphic LCD
Sign for status ZERO, TARE, NET,GROSS, STABLE, HOLD,
RX,TX,USB,UNIT(kg, lb, ton)
Division ×1, ×2, ×5, ×10, ×20, ×50
Tare Subtraction Full capacity
Display Below Zero “-”Minus
10

1-5. General Specifications
Power AC 85~264V, 50~60 Hz (20W)
Product Size 192(W) x 199(D) x 96 (H)
Temperature Range -10 ~ 40℃℃
Fuse Capacity T2A L250V
Product Weight Approx. 1.8 kg
1-6. Option Specification
Option - 1 Analog V-out (0 ~10V) or I-out (4~20mA)
Option – 2 Relay module
Option – 3 Relay module Type 2 (8in, 10out)
Option – 4 BCD Out
Option – 5 Ethernet
Option - 6 WiFi
Note 1. Ensure to affirm before purchasing the product since there may be
a limitation for the option module that can be used depending on
the program version.
11
Table of contents
Other CAS Accessories manuals

CAS
CAS CI-100A Installation and operating instructions

CAS
CAS NT-500 Series User manual

CAS
CAS CI-2400BS User manual

CAS
CAS CI-400 Series User manual

CAS
CAS NT-302A User manual

CAS
CAS RW Series User manual

CAS
CAS DH User manual

CAS
CAS CT100 Series User manual

CAS
CAS CI-2001A User manual

CAS
CAS EXP-2000A User manual