1 ABOUT THE OPERATING INSTRUCTIONS ...........................................................................................................................5
1.1 Symbols used ..........................................................................................................................................................................5
1.2 Definition of the term product ........................................................................................................................................5
1.3 Definition of the term system ..........................................................................................................................................6
1.4 Definition of the term büS .................................................................................................................................................6
1.5 Definition of the term "reagent unit" ............................................................................................................................6
2 INTENDED USE ....................................................................................................................................................................................6
3 BASIC SAFETY INFORMATION ....................................................................................................................................................7
4 GENERAL INFORMATION ................................................................................................................................................................8
4.1 Contact ........................................................................................................................................................................................8
4.2 Warranty conditions ..............................................................................................................................................................8
4.3 Information on the Internet ...............................................................................................................................................8
5 DESCRIPTION .......................................................................................................................................................................................9
5.1 General description and function ..................................................................................................................................9
5.2 Description of the product without housing for the type 8905 .....................................................................9
5.3 Description of the product mounted in a housing for the type 8905 .....................................................10
6 TECHNICAL DATA .............................................................................................................................................................................11
6.1 Conditions of use ................................................................................................................................................................11
6.2 Conformity to standards and directives .................................................................................................................11
6.3 Materials the product is made of ...............................................................................................................................11
6.4 Fluid data .................................................................................................................................................................................11
6.5 Measurement data .............................................................................................................................................................12
6.6 Electrical data .......................................................................................................................................................................12
6.7 Data transfer ..........................................................................................................................................................................12
7 INSTALLATION ...................................................................................................................................................................................13
7.1 Safety instructions .............................................................................................................................................................13
7.2 Installation on a wall of the product with housing for the type 8905 .....................................................13
7.3 Installation of the product without housing for the type 8905 ...................................................................13
7.3.1 Arrangement and equipment of the backplanes .........................................................................14
7.3.2 Mounting of the backplanes on 2 standard rails (TS35) ...........................................................15
Table of contents
English

2
7.3.3 Mounting the product on a 4 backplane combination ...............................................................15
7.3.4 Mounting the product on a 3 backplane combination ...............................................................16
7.3.5 Installation of the reagent unit .........................................................................................................17
7.4 Fluid system installation .................................................................................................................................................17
7.4.1 Fluidic connection of the product with housing ..........................................................................17
7.4.2 Fluidic connection of the product mounted on a standard rail ................................................17
7.5 Electrical connection .........................................................................................................................................................18
7.5.1 Pin assignment for the M12 connectors .......................................................................................18
7.5.2 Connecting the product with housing to the power supply and fieldbus .............................18
7.5.3 Electrically connecting the product without housing .................................................................20
8 COMMISSIONING ...........................................................................................................................................................................21
8.1 Safety instructions .............................................................................................................................................................21
8.2 Before commissioning the product ..........................................................................................................................21
8.3 Procedure for commissioning the product ...........................................................................................................22
8.4 Procedure for commissioning after a flow interruption .................................................................................22
9 ADJUSTMENT AND OPERATION ..............................................................................................................................................23
9.1 Safety instructions .............................................................................................................................................................23
9.2 How to adjust the product .............................................................................................................................................23
9.3 General information on the display software type ME21 ..............................................................................23
9.4 "Device" view of the product .........................................................................................................................................24
9.5 "Function" view of the product .....................................................................................................................................25
9.6 Detailed views of the büS function ...........................................................................................................................26
9.7 Setting the parameters of function FIA ..................................................................................................................28
9.7.1 Functions that can be adjusted in "Parameter" view ..................................................................28
9.7.2 Setting the time interval between 2 analyses ..............................................................................28
9.7.3 Setting the automatic start of a calibration...................................................................................29
9.7.4 Setting the automatic start of a cleaning cycle ...........................................................................29
9.7.5 Manually modifying the calibration values .......................................................................................... 30
9.7.6 Connecting the product with the reagent unit to monitor the operating agents
(only MZ30 with electronics) ...........................................................................................................30
9.7.7 Monitoring the fill level of the operating agents, MZ30 without electronics .........................31
9.7.8 Monitoring the fill level of the waste container ............................................................................31
9.7.9 Switching off the monitoring of the fill level of the waste container .......................................31
English

3
9.7.10 Setting the fill level of the waste container to zero .....................................................................32
9.7.11 Monitoring the expiration date of the operating agents (only MZ30 with electronics).......32
9.7.12 Monitoring the iron content .............................................................................................................32
9.8 Reading the product diagnosis ...................................................................................................................................33
9.8.1 Reading the current product status ...............................................................................................33
9.8.2 Reading the total operating time of the product .........................................................................33
9.8.3 Reading the number of analyses since first commissioning .....................................................34
9.8.4 Reading the number of analyses before the next automatic calibration ................................34
9.8.5 Reading the number of analyses before the next automatic cleaning ....................................34
9.8.6 Reading the connection status between the product and reagent unit ................................34
9.9 Setting maintenance work .............................................................................................................................................35
9.9.1 Reading the current function and tracking its progress ............................................................35
9.9.2 Reading the total and remaining time of a function in progress ..............................................36
9.9.3 Starting automatic analyses, calibrations and cleaning cycles ................................................36
9.9.4 Switching off automatic analyses, calibrations and cleaning cycles ......................................37
9.9.5 Setting the behaviour of the product after a power interruption .............................................37
9.9.6 Manually starting an analysis ...........................................................................................................38
9.9.7 Manually starting a calibration .........................................................................................................38
9.9.8 Manually starting a cleaning cycle ..................................................................................................39
9.9.9 Manually starting degassing ............................................................................................................39
9.9.10 Manually starting filling of the sample fluid system .....................................................................40
9.9.11 Manually starting filling of the reagent tube ..................................................................................40
9.9.12 Manually starting filling of the calibration tube .............................................................................40
9.9.13 Manually starting filling of the cleaning tube ................................................................................41
9.9.14 Manually starting commissioning ....................................................................................................41
9.9.15 Manually starting draining of the reagent tube ............................................................................42
9.9.16 Manually starting draining of the calibration tube .......................................................................42
9.9.17 Manually starting draining of the tube for cleaning solution .....................................................42
9.9.18 Activate or stop simulation of an iron content .............................................................................43
9.9.19 Hold the last measured value ..........................................................................................................44
9.9.20 Switching on the saving of the iron contents measured during calibration ..........................44
9.9.21 Switching off the saving of the iron contents measured during calibration ..........................44
9.9.22 Step-by-step replacement of operating agent bottles ..............................................................45
10 MAINTENANCE AND TROUBLESHOOTING .......................................................................................................................47
10.1 Safety instructions .............................................................................................................................................................47
English
Type MS06

4
10.2 Performing maintenance work ....................................................................................................................................47
10.3 Cleaning the outside of the product .........................................................................................................................47
10.4 Removal of the product from the backplane .......................................................................................................48
10.5 Troubleshooting, when no message is displayed .............................................................................................48
10.6 Troubleshooting if a message is displayed ..........................................................................................................49
10.6.1 Message "Low limit in reagent-solution tank detected" ............................................................49
10.6.2 Message "Low limit in cleaning-solution tank detected" ...........................................................49
10.6.3 Message "Low limit in calibration-solution tank detected" .......................................................50
10.6.4 Message "Measured Fe value too large" ......................................................................................50
10.6.5 Message "Measured Fe value too low" .........................................................................................51
10.6.6 Message "Waste container fill level limit reached" .....................................................................52
10.6.7 Message "Measured Fe value exceeds valid range" ..................................................................53
10.6.8 Message "Inlet temperature low limit" ...........................................................................................53
10.6.9 Message "Inlet temperature upper limit" .......................................................................................53
10.6.10 Message "The test of valves and pumps failed" ..........................................................................53
10.6.11 Message "Power supply voltage limit has been reached" ........................................................54
10.6.12 Message "Container 1 in MZ30 is placed at the wrong position" ..........................................54
10.6.13 Message "Container 2 in MZ30 is placed at the wrong position" ..........................................54
10.6.14 Message "Container 3 in MZ30 is placed at the wrong position" ..........................................55
10.6.15 Message "Reagent solution expiration date" ...............................................................................55
10.6.16 Message "Clean solution expiration date" ....................................................................................56
10.6.17 Message "Calibration solution expiration date" ...........................................................................56
10.6.18 Message "Communication with MZ30 failed" .............................................................................57
10.6.19 Message "Initializing communication with MZ30" ......................................................................57
10.6.20 Message "Automatic calibration failed" .........................................................................................57
11 SPARE PARTS AND ACCESSORIES ......................................................................................................................................58
12 PACKAGING, TRANSPORT ..........................................................................................................................................................58
13 STORAGE ..............................................................................................................................................................................................59
13.1 Storage of the product .....................................................................................................................................................59
13.2 Commissioning the product after a period of storage ...................................................................................59
14 DISPOSAL OF THE PRODUCT ..................................................................................................................................................59
English
Type MS06

5
About the Operating Instructions
1 ABOUT THE OPERATING INSTRUCTIONS
The Operating Instructions describe the entire life cycle of the product. Please keep these Operating Instructions
in a safe place, accessible to all users and any new owners.
The Operating Instructions contain important safety information.
Failure to comply with these instructions can lead to hazardous situations.
▶The Operating Instructions must be read and understood.
1.1 Symbols used
Danger
Warns against an imminent danger.
▶Failure to observe this warning results in death or in serious injury.
Warning
Warns against a potentially dangerous situation.
▶Failure to observe this warning can result in a serious injury or even death.
CaUTiOn
Warns against a possible risk.
▶Failure to observe this warning can result in substantial or minor injuries.
nOTiCe
Warns against material damage.
▶Failure to observe this warning may result in damage to the product or system.
Indicates additional information, advice or important recommendations.
Refers to information in the Operating Instructions or in other documents.
▶Indicates an instruction to be carried out to avoid a danger, a warning or a possible risk.
→Indicates a procedure to be carried out.
Indicates the result of a specific instruction.
1.2 Definition of the term product
The term "product" used within these Operating Instructions always refers to the sensor cube of the flow injection
analysis type MS06.
English
Type MS06

6
About the Operating Instructions
1.3 Definition of the term system
The term "system" used within these Operating Instructions, always refers to the Online Analysis System type
8905.
1.4 Definition of the term büS
The term "büS" used within these Operating Instructions always refers to the fieldbus developed by Bürkert.
1.5 Definition of the term "reagent unit"
The term "reagent unit" used within these Operating Instructions always refers to the reagent unit type MZ30.
2 INTENDED USE
Use of this product that does not comply with the instructions could present risks to people, nearby
installations and the environment.
The product is used for measuring dissolved iron in water and must be operated with reagent unit type MZ30.
▶This product must be protected against electromagnetic interference, ultraviolet rays and, when installed
outdoors, the effects of climatic conditions.
▶This product must be used in compliance with the characteristics and commissioning and use conditions
specified in the contractual documents and in the Operating Instructions.
▶Requirements for the safe and proper operation of the product are proper installation as well as careful opera-
tion and maintenance.
▶Only use the product as intended.
English
Type MS06

7
Basic safety information
3 BASIC SAFETY INFORMATION
This safety information does not take into account any contingencies or occurrences that may arise during instal-
lation, use and maintenance of the product.
The operating company is responsible for the respect of the local safety regulations including for the staff safety.
Danger
Danger due to the nature of the operating agents.
▶Observe the rules in force concerning accident prevention and safety and which relate to the use of hazard-
ous products.
▶Observe the information in the safety data sheet. The safety data sheets can be found at
- Reagent: http://sds-id.com/200123-8
- Cleaning solution: http://sds-id.com/200124-7
- Calibration solution: http://sds-id.com/200122-9
▶Use a waste container of at least 2.5 litres.
▶Dispose of waste containing chemicals produced by the system in an environmentally friendly manner.
Various dangerous situations.
To avoid personal injury take care:
▶to prevent any unintentional power supply switch-on.
▶to carry out the installation and maintenance work by qualified and skilled staff with the appropriate tools.
▶to use the product only if in perfect working order and in compliance with the instructions provided in these
Operating Instructions
▶to observe the general technical rules.
▶not to use the product in explosive atmospheres.
▶not to use the product in an environment incompatible with the materials from which the product is made.
▶not to make any modifications to the product.
nOTiCe
Elements/components sensitive to electrostatic discharges.
This product contains electronic components sensitive to electrostatic discharges They may be damaged if they
are touched by an electrostatically charged person or object. In the worst-case scenario, these components are
instantly destroyed or go out of order as soon as they are activated.
• To minimize or even avoid all damage due to electrostatic discharge, take all the precautions described in the
EN 61340-5-1 norm.
• Do not touch any of the live electrical components.
English
Type MS06

8
General information
4 GENERAL INFORMATION
4.1 Contact
To contact the manufacturer of the product, use the following address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL
The addresses of our international branches can be found on the Internet at: www.burkert.com
4.2 Warranty conditions
The condition governing the legal warranty is the conforming use of the product in observance of the operating
conditions specified in these Operating Instructions.
4.3 Information on the Internet
You can find the Operating Instructions and technical data sheets regarding type MS06 at: www.burkert.com
English
Type MS06
Table of contents
Other Burkert Accessories manuals

Burkert
Burkert S070 User manual

Burkert
Burkert SE30 Ex Namur User manual

Burkert
Burkert GENERIC 8400 User manual

Burkert
Burkert 8030 User manual

Burkert
Burkert 8694 User manual

Burkert
Burkert 8020 User manual

Burkert
Burkert 2509 User manual

Burkert
Burkert 8020 User manual

Burkert
Burkert 8020 User manual

Burkert
Burkert 8223 User manual

Burkert
Burkert 8030 User manual

Burkert
Burkert 8741 User manual

Burkert
Burkert 8007 User manual

Burkert
Burkert FULLBORE S056 User manual

Burkert
Burkert 8020 Low Power Installation and operating instructions

Burkert
Burkert MS09 User manual

Burkert
Burkert 8071 User manual

Burkert
Burkert MS05 User manual

Burkert
Burkert GENERIC 8400 User manual

Burkert
Burkert 8221 User manual