BRAYER BR4901 User manual

Instruction manual
Инструкция по эксплуатации
Air purifier BR4901
Очиститель воздуха BR4901
brayer.ru

СОДЕРЖАНИЕ
EN......................................................................................................................................3
DE....................................................................................................................................16
RU ...................................................................................................................................30
KZ....................................................................................................................................44

3
EN
AIR PURIFIER BR4901
An air purier is an appliance intended for cleaning
the air from dust, microbes, pet hair, tobacco smoke
as well as allergens, bacteria and unpleasant odours.
The built-in air humidier is intended for maintaining
an optimal relative humidity in the room.
DESCRIPTION
1. Control/indication panel
2. Room air cleanness indicator
3. Detachable front lid
4. Room humidity sensor
5. Air cleanness sensor
6. Carrying handle
7. Air outlet grid
8. Body
9. Water tank
10. Drain plug
Control/indication panel (1)
11. On/o button « On»
12. Timer on/o button « Timer»
13. Humidier on/o button « Humidier»
14. Automatic mode on/o button « Auto»
15. Speed operation mode selection button « Speed»
16. Night mode on/o button « Night»
EN
17. UV lamp on/o button « UV lamp»
18. Ionization mode on/o button « Ionization»
19. Operation mode icons «
STERILIZE
, SLEEP ,
AUTO
,
ANION
»
20. Air purier operation/standby mode symbol « »
21. Room relative humidity digits
22. Timer operation time digits
23. Humidity intensity symbol «
MIST
»
24. Speed operation mode symbol «
SPEED
»
Remote control (33)
25. On/O button « On»
26. Night mode on/o button «Night»
27. UV lamp on/o button «UV lamp»
28. Timer on/o button «Timer»
29. Speed operation mode selection button « Speed»
30. Humidier on/o button « Humidier»
31. Automatic mode on/o button « Auto»
32. Ionization mode on/o button «Ionization»
33. Remote control
34. Battery holder

4 EN
MIST
ON/OFF
TIMER
SPEED
ANION
STERILIZE
SLEEP
AUTO
SPEED
MIST
SLEEP
STERILIZE
AUTO
ANION
HUMIDITY
TIMER
3
1114201915
16 21 22 23 24 12
18
17 13
19
5
4
2
6
7
8
9
10
1

5EN
30
29
28
27
26
25 31
32
33
34
Рiс. 1
Рiс. 4 Рiс. 8
Рiс. 2
Рiс. 5
Рiс. 9 Рiс. 11
Рiс. 12 Рiс. 13 Рiс. 14 Рiс. 15 Рiс. 16 Рiс. 17
Рiс. 10
Рiс. 6 Рiс. 7
Рiс. 3

6
EN
AIR PURIFIER FEATURES
Filters, an air ionizer and an antibacterial UV lamp are
used to clean the indoor air.
Cold catalytic lter:
• The cold catalytic lter lters harmful gases and such
compounds as formaldehyde, ammonia and benzol,
decomposing them into water and carbon dioxide.
Coal lter:
• Activated carbon absorbs unpleasant odors and
tobacco smoke, holds allergens, keeps pollen of
plants and animal hair.
Antibacterial lter:
• The lter is aimed at ghting bacteria and viruses, it
also eectively holds allergens.
НЕРА lter:
• The HEPA lter cleans the air from dust particles
with a diameter of less than 2.5 microns, holds plant
pollen, dangerous viruses and bacteria.
Air ionizer:
• The ionizer saturates the air with negatively charged
ions, which are necessary for the normal life of
people, animals and plants. In the ionization mode
you feel clean, almost mountain air.
UV lamp:
• The UV lamp emission destroys bacteria and viruses.
«Air cleanness» smart sensor:
The smart sensor automatically sets the speed
operating mode of the air purier based on the indoor
air pollution. The air cleanness level is indicated by
color indication on the scale (14) «Air cleanness»:
- red (polluted air);
- yellow (normal air composition);
- green (clean air).
Air Humidier:
- Insucient room air humidity (especially during the
heating season) negatively aects humans’ and
pets’ health as well as plants and furniture.
- If the relative humidity in the room is low, you can
switch the air humidier on.
- High-frequency vibration of the sprayer divides
water into the smallest particles of 1-5 micron in
size. Cold water «mist» mixes well with the air and
increases the relative air humidity.
ATTENTION! The air purier does not retain such
gases as carbonic oxide (CO) or radon (Rn) and
it cannot be used for air purifying in case of re or
dangerous chemical release.

7
EN
SAFETY MEASURES AND OPERATION
RECOMMENDATIONS
Read the operation instructions carefully before
using the air purier, after reading keep them for
future reference.
• Use the unit for its intended purpose only, as it is
stated in this manual.
• Mishandling the unit can lead to its breakage and
cause harm to the user or damage to the user’s
property, which is not covered by warranty.
• Protect the unit from impacts, falling, vibrations and
other mechanical stress.
• Never leave the unit connected to the mains
unattended.
• Do not use the unit near heating appliances, heat
sources or open ame.
• Do not use the unit in places where aerosols are
used or sprayed, and in proximity to inammable
liquids.
• Do not immerse the air purier, the power cord or the
power plug into water or any other liquids.
• Do not use the unit in proximity to the kitchen sink, in
bathrooms, near swimming pools or other containers
lled with water.
• If the unit is dropped into water, unplug it
immediately, and only then you can take the unit out
of water.
• Do not let the power cord touch hot surfaces and
sharp edges of furniture.
• Unplug the unit after usage or before cleaning. When
unplugging the unit, hold the power plug and carefully
remove it from the mains socket, do not pull the
power cord, as this can lead to its damage and cause
a short circuit.
• Do not touch the unit body, the power cord and the
power plug with wet hands.
• Use only the removable parts supplied with the unit.
• Use tap water cleaned with domestic water lters,
distilled or boiled water. The water temperature
should not exceed +40°С.
Attention! A lithium battery is used in the remote
control. To avoid danger, do not allow children to play
with the battery. If your child has swallowed a battery,
immediately see a doctor.
• Make sure that operating voltage of the unit indicated
on the label corresponds to your home mains
voltage.
• Do not connect the unit to external timers or remote
control mains sockets.
• Place and use the air purier on a at dry and steady
surface. The distance between the unit body and
other furniture and interior objects should be at least
50 cm and 80 cm above the unit.
• Do not use the air purier outdoors.
• It is recommended not to use the unit during lightning
storms.

8
EN
• Do not use sparkling or dirty water, do not add any
perfume additives into the water tank.
• Do not switch the unit on without water tank or if the
water tank is empty.
• Switch the air humidier o when the water tank is
empty.
• Unplug the unit before removing the water tank.
• Do not cover the air purier during the operation.
• Do not cover the air inlets on the unit body and avoid
getting of foreign objects inside them.
• Clean the unit regularly.
• For child safety reasons do not leave polyethylene
bags used as packaging unattended.
• The unit is not intended for usage by physically,
sensory, psychically or mentally disabled persons
(including children) or by persons lacking experience
or knowledge if they are not under supervision of a
person who is responsible for their safety or if they
are not instructed by this person on the usage of the
unit.
• From time to time check the power cord integrity.
• If the power cord is damaged, it should be replaced
by the manufacturer, a maintenance service or
similar qualied personnel to avoid danger.
• Do not repair the unit by yourself. Do not
disassemble the unit by yourself, if any malfunction
is detected, and after the unit was dropped, unplug it
and apply to the service center.
• To avoid damages, transport the unit in the original
package.
• Keep the unit in a dry cool place out of reach of
children and disabled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USE
ONLY, DO NOT USE THE UNIT FOR COMMERCIAL
OR LABORATORY PURPOSES.
BEFORE THE FIRST USE
After unit transportation or storage at negative
temperature, unpack it and wait for 3 hours before
using.
• Unpack the unit and remove all the packaging
materials.
Attention! Do not allow children to play with
polyethylene bags or packaging lm. Danger of
suocation!
• The unit is not intended for usage by children.
• Do not leave children unattended to prevent using
the unit as a toy.
• Do not allow children to touch the operating surface,
the unit body, the power cord or the power plug
during operation of the unit.
• Be especially careful if children or disabled persons
are near the operating unit.
• During the unit operation and breaks between
operation cycles, place the unit out of reach of
children.

9
EN
• Keep the original package.
• Read the safety measures and operating
recommendations.
• Check the delivery set.
• Examine the unit for damages, in case of damage do
not plug it into the mains.
• Make sure that specied specications of power
supply voltage of the unit correspond to the
specications of your mains.
Remote control (33)
- remove the battery if you are not planning to use
the unit for a long time;
- remove the used battery from the remote control
(33) and dispose of it.
Preparing the lters before the using the air purier
• Remove the lid (1) (pic. 2).
• Turn the locks and remove the lters (pic. 3).
• Unpack the lters (pic. 4).
• Install the rst two-piece (antibacterial + HEPA lter)
into the air purier body, make sure that the »puller”
is pointing towards you (pic. 5).
• Install the second two-piece (catalytic + coal lter),
make sure that the »puller” is pointing towards you
(pic. 6).
• Fix the lters by turning the locks (pic. 7).
• Install the front lid (1) back to its place (pic. 8).
• The air purier is ready for operation.
USING THE AIR PURIFIER
• Place and use the air purier on a at dry and steady
surface. The distance between the unit body and
other furniture and interior objects should be at least
50 cm and 80 cm above the unit.
Switching on
• Connect the unit to the mains, you will hear a sound
signal and the symbols (22) «00» will appear on the
control/indication panel (1).
Attention! A lithium battery is used in the remote
control. To avoid danger, do not allow children to play
with the battery. If your child has swallowed a battery,
immediately see a doctor.
Battery installation/replacing (pic. 1)
• Press on the clamp and remove the battery holder
(34) from the remote control (33) body, insert a
CR2025 battery (supplied with the unit) into the
holder, strictly following the polarity.
• Install the battery holder (34) into the remote control
(33).
Notes:
- if there is an isolation insert, remove it.
- replace the battery in time;
- do not recharge the lithium battery;

10
EN
• Every pressing of the active button is accompanied
by a sound signal.
• Press the button (11) « On» on the control/
indication panel (1) or the button (25) « On» on
the remote control (33), the air purier will switch on
in the ready mode, and the symbol (20) « » will
start ashing.
• To switch the air purier o, press the button (11) «
On» on the control/indication panel (1) or press the
button (25) « On» on the remote control (33). The
symbol (20) « » will go out and after that you
can unplug the unit.
Notes:
- when any operating mode is switched on, the
symbol «
HUMIDITY
» will be displayed and the relative
humidity in the room will be shown with digital
symbols (21);
- the relative humidity level readings may be slightly
dierent from the readings of another hygrometer.
Humidier switch o timer
• To switch the timer on, press the button (12) «
Timer» on the control/indication panel (1) or press the
button (28) «Timer» on the remote control (33), the
symbol «
TIMER
» will appear on the control/indication
panel (1) and the digits (22) will show the timer
operation time.
• By consequently pressing the button (12) « Timer»
on the control/indication panel (1) or the button (28)
«Timer» on the remote control (33), set the timer
operation time, the operation time is displayed by the
digits (22).
• Timer setting time is from 1 to 12 hours.
• When the timer is switched on, the air cleanness
smart sensor is activated. The air purier will
automatically adjust the speed depending on the air
cleanness.
• The air cleanness level is displayed with the indicator
(2):
- red (polluted air);
- yellow (normal air composition);
- green (clean air).
• To switch the timer o, repeatedly press the button
(12) « Timer» on the control/indication panel (1),
or the button (28) «Timer» on the remote control (33)
until the timer operation time digits (22) go out, and
the symbol «
TIMER
» goes out.
Air humidier
ATTENTION! If you nd a water leak from the tank
(9), immediately switch the air purier o, place a
suitable container under the drain plug (10), remove
the plug (10) (pic. 12), drain the water, leave the
unit in an upright position for 40-50 minutes to dry,
reinstall the plug (10), contact the service center for
testing or repair of the air purier.
Table of contents
Languages:
Other BRAYER Air Cleaner manuals




















