Amcor PLDA 19E User manual

PLDA 19E 19EH 25E 25EH
HOME TREATMENT CENTRE
www.amcorgroup.com
DBedienungsanleitung
家庭空氣處理器
家庭空气处理器
LUFTREINIGER
GB Instruction Manual
TC 說明書
SC 用户手册

GB
2
THANK YOU !
• Never operate this appliance if it is damaged or if it has a damaged cord or plug.
• Do not lead the cord over sharp edges.
• A damaged supply cord should be replaced by the manufacturer, its service agent
or a qualied person in order to avoid a hazard.
• Any service other than regular cleaning or replacing the carbon lter should be
performed by an authorized service representative. Failure to do so could result in
a loss of warranty.
The rst time that you use the unit please ensure that it has been standing for
2 hours in an upright position before it is switched on.
IMPORTANT: The unit is not to be used in temperatures under 5 °C.
Thank you for choosing this innovative amcor product. We suggest that you keep
this manual in a safe place for future reference. It describes the many benets and
advanced features this unique product has to offer. Before you use it, you should
carefully read these instructions to maximise this product’s performance.
For over 50 years amcor has specialised in complete indoor environmental control,
manufacturing and marketing dehumidiers, portable air conditioners, coolers, air
puriers, ionisers and aromatherapy scent diffusers. These world class products
incorporate the latest technological developments.
IMPORTANT SAFETY INSTRUCTIONS
Before any installation, use and maintenance operation, read the safety instructions
in this manual carefully.
Remove all packaging materials from the unit, keep it away from babies and small
children to avoid the danger of suffocation.
Before inserting the plug make sure that the voltage is within the range indicated on
the rating label on the unit.
The dehumidier is intended exclusively for the use for which it was created. Amcor
is not responsible for any damage caused by improper use.
The dehumidier is safe, however as with other electrical appliances, use it with
care.
WARNING

GB
IMPORTANT!
• The unit is designed for indoor operation.
• Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet.
• The installation must be in accordance with regulations of the country where the
unit is used.
If you are in any doubt about the electrical installation, have it checked and if
necessary modied by a qualied electrician.
• Unplug when not in use. Do not unplug by pulling the cord.
• Do not operate this product with wet hands.
• Keep out of the reach of children.
• Do not clean the unit by spraying it or immersing it in water.
• Disconnect it from the mains before cleaning the unit or any of its components.
• Always unplug before changing the carbon lter.
• Do not connect the unit to an electrical outlet using an extension cord. If an
outlet is not available, one should be installed by a licensed electrician.
• Keep at least 20cm distance from the wind outlet to the combustible surfaces,
when the heater is on.
Do not use your PLDA under the following conditions:
Close to a heat
source
Inside unit exposed
to the weather
outdoors
In a permanent
very humid
environment
If the power cable
wires are frayed
or cut
When small
children may be
left unattended
If an extension
cord is needed to
reach an outlet
Where the power
cable may be
damaged
On a slope or
uneven surface
Where it may
be damaged by
chemicals
Where there is a
risk of interference
by foreign objects
This product is
not made for DIY
repair
If there is a risk of
liquid falling on
the unit
Fan
Motor
Proximity
switch
Water tank
Micro switch
Condenser
(warmed coil)
Evaporator
(cold refrigerated coil)
Buoy
Compressor
Door switch
Proximity
switch
Water tank
Moist
air
Moist ai
r
Warmer dry air
a
b
c
d
e
f

GB
HOW IT WORKS
Your Amcor PLDA draws air through a multi stage high efciency washable lter
onto a refrigerated cold coil. As the air in the room passes over the cold surface,
moisture condenses and collects into a removable water tank. The drier, slightly
warmer air is then expelled through the air outlet located behind the control panel
of the unit into the room.
When the water tank is full, a micro-switch automatically stops the unit and an
indicator light signals the need to empty the tank.
If preferred a continuous drainage hose connected into the back of the unit can be
used to drain the water.
The dehumidier ghts condensation, mould and dampness throughout the house.
It protects your furniture, precious possessions and decor from the damaging
effects of excessive moisture.
The combination of air purier and dehumidier may aid in relieving some medical
conditions such as arthritis and allergies linked to high humidity and airborne
allergens by removing excess moisture, dust, smoke, animal dander, mould spores
and pollen to create a less irritating living environment for your enjoyment.
The air is cleaned both when the dehumidier is operating and also independently
of the dehumidier when the air purier mode is selected.
Your PLDA is also great for drying the laundry! But please do not put the clothes on
the unit directly.
Close to a heat
source
Inside unit exposed
to the weather
outdoors
In a permanent
very humid
environment
If the power cable
wires are frayed
or cut
When small
children may be
left unattended
If an extension
cord is needed to
reach an outlet
Where the power
cable may be
damaged
On a slope or
uneven surface
Where it may
be damaged by
chemicals
Where there is a
risk of interference
by foreign objects
This product is
not made for DIY
repair
If there is a risk of
liquid falling on
the unit
Fan
Motor
Proximity
switch
Water tank
Micro switch
Condenser
(warmed coil)
Evaporator
(cold refrigerated coil)
Buoy
Compressor
Door switch
Proximity
switch
Water tank
Moist
air
Moist ai
r
Warmer dry air
a
b
c
d
e
f

GB
5
HOW IT WORKS
PARTS
PLACEMENT
a. Carbon lter
b. Scent emitter
c. Adapter for d.
d. Spot dehumidication hose
e. 3M™ High Air Flow lter
(optional)
Your Amcor PLDA will begin to protect your home from the harmful effects of exces-
sive moisture as soon as it is turned on.
Excess moisture travels throughout your home, in the same way that cooking smells
spread to every room in the house. For this reason, the dehumidier should be
positioned in a central and clear location so that it can draw this moist air towards
it from all over the home. A warm hallway or landing is an excellent position for your
dehumidier. If possible, leave interior doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by positioning
the dehumidier there and later moving it to a more central point.
For the most effective use, run your dehumidier with external doors and windows
kept closed when the dehumidier is operating.
Please note the unit should not be placed directly against a radiator or other heat
source.
When positioning your AMCOR PLDA, ensure that it is placed securely on a
level surface clear of any obstacle that may limit the air movement.
Your AMCOR PLDA is tted with 4 wheels for easy movement.
Before you move the unit, switch it off and empty the water tank.
a
b
c
d
e

GB
AIR PURIFYING
Your PLDA is tted with a high denition multi-stage air purication system.
Stage one
A preliminary washable dust lter. The lter absorbs irritating odours such as that
from mould, stale cigar smoke, or vehicle fumes so they are not recirculated into
the cleaner air.
Stage two
An activated carbon odour absorbent lter.
Stage three (optional)
An optional 3M™ High Air Flow lter or a TiO2 lter for purifying the air from
bacteria.
Remember
You can use the air purier function even when dehumidication is not needed.
Simply press the UV push button and set the humidity level to 80%.
For details on cleaning the lter see the section of maintenance.
5678
10
12
9
1
2
3
4
11
13

GB
AIR PURIFYING CONTROLS
1. Humidity set mode.
2. High fan speed.
3. Low fan speed.
4. Dehumidication – compressor runs.
5. Timer set is on.
6. Setting the timer ON.
7. Setting the timer OFF.
8. Real time indication and timer setting(s).
9. Indication of room relative humidity and temperature.
In all units – it also indicates the timer setting status as follows:
– setting the rst timer – Setting the second timer
– the rst timer ( )is conrmed – the second timer ( )is conrmed.
10. Ultra violet light is on (where available).
11. Heating function is ON. (for PLDA 19EH & 25EH)
12. Water tank full.
13. Dual colour led indication.
1. When the unit is switched ON the led colour is BLUE.
2. When the water tank is full the led colour turns RED.
..
..
..
..
..
..
5678
10
12
9
1
2
3
4
11
13

GB
Setting the time
..
The real time is shown on the clock, the 4 digits at the bottom of the LCD.
The moment the unit is connected to the electricity, the default time 12:00 is shown.
Push the SET BUTTON for 2 seconds, the 2 left digits will blink, adjust the hour by
pressing the
..
or
..
button repeatedly.
To set the minutes push the SET BUTTON again for 2 seconds. The 2 right digits
blink. Press the
..
or
..
button repeatedly to adjust the minutes.
Push the SET BUTTON again and the real time is set.
Switching the unit ON and OFF
Push the
..
BUTTON to operate the dehumidier. Pushing the button again will
switch the unit off.
Setting the humidity level
..
CONT = Continuous dehumidication, the unit is dehumidifying disregarding the
relative humidity in the room.
50% maintains the relative humidity around 50%, ideal for personal comfort and dry
storage.
60% maintains the relative humidity around 60% for personal comfort.
70% maintains the relative humidity around 70% in the room.
80% maintains the relative humidity around 80% in most cases the compressor will
be OFF.
To set the desired relative humidity level press the
..
or
..
button repeatedly.
Setting the fan speed.
Push the SPEED BUTTON to change the fan speed, the chosen speed will be
indicated on the LCD,
..
for the high speed and
..
for the low speed.
Setting the Timer
..
The timer switches the unit on and off automatically.
Make sure that the clock is set to the real time so that the timer can operate the unit
accurately.
When the unit runs (is ON)
Push the TIMER BUTTON, the 2 left digits will blink; adjust the desired hour when
the unit will switch OFF by repeatedly pressing the
..
or
..
button. Push the TIMER
BUTTON again, the 2 right digits will blink; adjust the minutes by repeatedly press-
ing the
..
or
..
button. (The minutes can be set insteps of 5 minutes, 5, 10, 15 up to
55). Press SET BUTTON to conrm the desired timer and
..
will be displayed.
If an ON setting is desired after the OFF, repeat the above procedure. (
..
will
be displayed accordingly)
To activate the timer settings push the SET BUTTON one more timer.

GB
9
When the unit is OFF.
Follow the same procedure as above for the ON and if required continue to the OFF
setting.
Cancelling the timer
In order to cancel the timer setting(s), push the TIMER BUTTON.
Blue light in the UV light range
..
Normally the blue UV light will be ON whenever the unit is connected to the
electricity. In order to turn the blue UV light off, push the UV BUTTON, the UV light
will go OFF and the UV icon on the LCD will disappear.
Pushing the UV BUTTON again will light the UV light.
When the front door opens, a micro switch cuts off the electricity.
Heater
..
( for PLDA 19EH & 25EH)
The heating function may run together with the compressor or alone. The heater will
run only when the room temperature is below 25 °C.
To operate the heating function, press the TEMP&HEAT BUTTON.
Room relative humidity
..
Normally the 2 digits indicate the relative humidity % in the room.
If the relative humidity is lower then 35% the 2 digit icon indicate
..
If the relative humidity is higher then 95% the 2 digit icon indicate
..
Room temperature
Push the TEMP&HEAT BUTTON for 2 seconds and the LCD will indicate the room
temperature.
SCENT EMITTER
The unit is supplied with a scent emitter to fragrance
the air.
• take out the scent capsule from its bag.
• take the scent emitter cover off by turning it and
pulling it out.
• x the capsule into its airy seat in the back of the
unit.
• return the cover to its place.

GB
10
MAINTENANCE
Always unplug the unit from the mains before carrying out any maintenance or clean-
ing the unit.
Cleaning the body
Use only a soft cloth to wipe the unit clean.
Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other
harmful cleansing solutions. These could all possibly damage the cabinet.
Cleaning the washable air lter
This dehumidier is equipped with a washable lter. This will capture most airborne
pollutants like dust, smoke, animal dander, mould spores and pollen to create a less
irritating living environment.
It is advisable to check the lter on a regular basis (at least monthly and after stor-
age) and clean as necessary:
• Extract the lter holder
• Use a vacuum cleaner or tap the lter lightly.
If the lter is particularly dirty, use luke-warm water with a small amount of medium
strength detergent and rinse thoroughly under the cold water tap.
Make sure the lter is completely dry before replacing.
Do not expose the lter to sunlight or other sources of direct heat as this may cause
the lter and frame to warp.
Cleaning and replacing the carbon lter.
The carbon lter can be cleaned with a vacuum cleaner, never rinse it with water. We
suggest to replace the carbon lter every 6 months.
Optional lters
3M™ High Air Flow lter
PCO – Photo Catalytic Oxidation (optional)
TiO2 lter is included in the multi air lter.
STORAGE
If the dehumidier is not used for long periods of time, follow these steps:
• disconnect the unit and wrap the power cable.
• if used, empty the water container, remove the scent emitter .
• clean the unit and lter, pack it in its original packaging or cover to protect against
dust.
• store the unit in an upright position in a cool, dry place away from access by chil-
dren.
This manual suits for next models
3
Table of contents
Languages:
Other Amcor Air Cleaner manuals

Amcor
Amcor AM-70 User manual

Amcor
Amcor AM-90 User manual

Amcor
Amcor UltrClean AM-70 Ficus User manual

Amcor
Amcor 1 User manual

Amcor
Amcor AM-90 User manual

Amcor
Amcor AIR PROCESSOR 2000 User manual

Amcor
Amcor AM-70 User manual

Amcor
Amcor HEPA TOWER plus User manual

Amcor
Amcor AM-12 User manual

Amcor
Amcor AM-45 User manual