Air purifi er with the AMCOR exclusive high-tech pure carbon ion generator.
带有AMCOR独有的高科技纯碳离子发生器的空气净化器。
帶有AMCOR獨有的高科技純碳離子發生器的空氣淨化機。
Luftreiniger mit außerordentlicher Wirkung dank des exklusiven, von AMCOR patentierten
Ionen-Generators aus Kohlenstoffaser.

GB
3
DO NOT USE YOUR AIR PURIFIER UNDER THE FOLLOWING CONDITIONS:
Close to a heat
source
Inside unit exposed
to the weather
outdoors
In a permanent
very humid
environment
If the power cable
wires are frayed
or cut
When small
children may be
left unattended
If an extension
cord is needed to
reach an outlet
Where the power
cable may be
damaged
On a slope or
uneven surface
Where it may
be damaged by
chemicals
Where there is a
risk of interference
by foreign objects
This product is
not made for DIY
repair
If there is a risk of
liquid falling on
the unit
For safety reasons, read this manual carefully before operating.
Persons who are not familiar with this manual must not use this product.
We strongly recommend keeping this manual in a safe place for future reference.
GENERAL SAFETY
THANK YOU
A word to AM-40 owners:
This manual has been prepared to acquaint you with the proper installation,
operation and maintenance of your AM-40. We urge you to read this publication
carefully and to follow the recommendations to help assure the most enjoyable and
trouble-free operation of your AMCOR unit.
When it comes to service, remember that AMCOR knows its product best. Please
do not attempt to open, repair and/or clean any of the internal parts of the
AM-40 yourself. This could result in the loss of warranty.
We would like to take this opportunity to thank you for choosing an AMCOR
product and to assure you of our continuing interest in your comfort, pleasure and
satisfaction.

GB
4
ELECTRICAL SAFETYHOW IT WORKS
A. POLLUTED AIR, WITH POSITIVELY CHARGED IONS
Stage 1: Electrostatic Dust-holding Capacity Filter
Friction caused by air passing through the first honeycomb filter creates an
electrostatic charge that captures and retains pollutants, dust and dirt.
Stage 2: Open Pore Polyurethane Foam
The foam is very permeable and has an extremely high dust-holding capacity.
Stage 3: A second honeycomb filter also captures and retains pollutants, dust and
dirt.
Stage 4: Scent Emitter
The user may add a pleasant scent to the air with the scent emitter option. The
system is environmentally friendly since it uses a blower to disperse the scent
instead of dispersing harmful fluorocarbons. The scent comes in replaceable
capsules which are easily inserted.
The scents are pleasant, unobtrusive and barely suggestive.
Stage 5: Ionization
This stage is of utmost importance as it restores the natural balance of the air.
After the air is purified, it is further cleaned and ionized at the air outlet using
AMCOR’s patented carbon filament process.
* Ionization substantially reduces the amount of indoor bacteria in the air.
* Ionization can frequently help asthma and allergy sufferers.
* Ionization may help relieve
weather related maladies
such as headaches, nausea
and physical aches.
* Ionization may help
lower tension, producing
sounder sleep.
B. CLEANED AND IONIZED
MOVING AIR
C. STAGES 1-3 ARE
CONTAINED IN A SINGLE,
EASY TO CLEAN CASSETTE.
1
3
4
5
2
A
B
C

GB
5
* The AM-40 is safe. It is approved by many safety institutions around the world.
However, as with other electrical appliance, use it with care.
* Do not clean the AM-40 by spraying it or immersing it in water.
* Do not insert any object into the opening of the AM-40.
* Disconnect the product from the mains before cleaning the unit or any of its
components.
* A slight sensation may be felt if the carbon filament ionizing element (the carbon
cord on the front air outlet) is touched. This is normal and presents no danger.
This sensation may also be felt if you touch a person or a large metal object while
your other hand is on the unit.
* WHEN NOT IN USE, STORE OUT OF THE REACH OF CHILDREN!
* WARNING:
Any service, other than regular cleaning or filter replacement, should be
performed by an authorized service representative. Failure to do so could result in
loss of warranty.
Never operate this appliance if it has a damaged cable or plug. Do not jam the
cable or lead it over sharp edges.
Damaged cords or plugs can be life-threatening. They must be replaced only by
an approved customer service department or similarly qualified personnel.
ELECTRICAL SAFETY
Caution
In order to prevent dirt build-up, it is recommended to keep the unit at least 1.5 ft.
(45 cm) from any non-washable surface. The air outlet should face away from the
wall.
The principle upon which the ionizer works is ionization. The process of ionization
accelerates the fallout of pollutants from the air. These pollutants may adhere to
surrounding surfaces, causing a dark smudge. Therefore, placement of the unit
away from all non-washable surfaces is a must!

GB
6
INSTALLATION
Attention: Before deciding on a location for your AM-40 AIR PURIFIER, carefully
read all the operating instructions as well as the following information.
The AM-40 ensures a minimum of 1000 negative air ions per cubic centimeter in an
area of 18 ft. (6 m) x 12 ft. (4 m) = 220 sq.ft. (24 sq.m).
Effective range: up to 18 ft. (6 m).
Installation of the AM-40
a) Never place this unit in close proximity to (at least 3-4 ft. away from) electronic
devices that contain electronic circuits, or are damaged by electrical fields.
Examples are: video tapes, audio tapes, floppy disks, computers, wrist watches,
touch lamps, radios, stereos, telephones, VCRs, etc.
b) Never place this unit on metal shelving or on any electrical devices.
c) The AM-40 may be placed on a nightstand, table or desk with its air outlet facing
the user. In order to allow for proper air flow and to reduce particle build-up,
always keep your unit at least 1.5 ft. (45 cm) from any wall. The air outlet should
always face away from the wall.
Instructions for use of the AM-40
The AM-40 may be operated all day or night. The air velocity can be regulated
either by the blower’s two-speed switch or by moving the AM-40 towards or away
from the user.
A. Checking the operation of the AM-40
When the light goes on, your air purifier is in operation (see control switch
diagram, page 8).
Before operating your unit:
B. Using the scent release function (optional)
Your air purifier can also disperse a pleasant scent. To do so, a scent release
capsule may be purchased from your dealer or ordered directly from us. One
scent release capsule is provided with the unit. These scents are pleasant,
unobtrusive and barely suggestive. The capsules are made of Polyiff®.
Polyiff® is produced by IFF, the world’s largest manufacturer of flavorings and
fragrances.
OPERATION

GB
7
To use the scent release function:
The capsule is installed on the right
side of the lower enclosure on the
front of your appliance (see fig. 1, page
2) To install, SWITCH OFF the unit.
Remove the capsule from its protective
wrapping. Open the capsule cap by
turning it in the direction opposite to
that indicated by the arrow on the cap
(see fig. 1, page 2). Insert the capsule in
the cap until the tabs catch the cap (see
fig. 2, page 2). Insert the complete cap
(with the capsule inside it) into the air
purifier and turn the cap in the direction
of the arrow (see fig. 3, page 2). Your
air purifier will now release a pleasant
fragrance during operation.
To replace the capsule, SWITCH OFF
the unit.
First remove the cap from the air
purifier by turning it in the direction
opposite to that indicated by the arrow
(see fig. 1, page 2).
Press the tabs together and remove the
used capsule (see fig. 4, page 2).
Replace the used capsule with a new
one (see fig. 3, page 2).
To deactivate the scent release function:
Remove the capsule and store in a glass jar with a tight lid (if the capsule is
still active). Store the empty cap inside the lower enclosure.
C. The AMCOR ionoscope, an ion detector (see fig. 5, page 2)
What is an ionoscope?
The ionoscope is a device that detects the negative ions emitted from the ion
generator. It proves visually to the user that the ion generator is functioning.
INSTALLATION
OPERATION

GB
8
TECHNICAL DATA
How to use the ionoscope
After switching on the unit, hold the ionoscope with your thumb on the area
marked “thumb position”.
Touch the ionizing element (the carbon cord on the front of the air outlet) with
the bare metal strip on the underside of the ionoscope. The neon bulb on the
tester will begin to blink.
When you turn off the ionizer or move the ionoscope away, the ionoscope’s
neon bulb will stop blinking. This shows that no more negative ions are being
generated into the air.
Note:
Do not worry if the light on the ionoscope continues to blink after the appliance
is turned off. This just means that negative ions recently emitted by the unit are
still in the vicinity.
Routine service and cleaning
Regular maintenance of the unit will maintain its effectiveness.
Before cleaning this unit, unplug it from the electrical outlet!
A. Cleaning the filter
a. Lift the filter cover (see fig. 6 , page 2) using the recesses on the sides of the
appliance, then remove the filter cassette (see fig.6 , page 2). Clean the filter by
dusting and then washing it in a mild detergent solution.
DRY THE FILTER CASSETTE COMPLETELY BEFORE RE-INSTALLATION!
b. Install the dry filter cassette on top of the appliance. Push the filter cassette
forward until it is properly seated. The filter cassette is symmetrical. Do not
worry which way you place it.
c. Replace the filter cover, making sure to insert the two pins on the filter cover
through the holes in the cassette into the upper enclosure (see fig. 6, page 2).
Frequency of cleaning
It is recommended to clean the filter every 2 weeks.
B. Enclosure cleaning
Clean the outside of the unit at least once a week with a damp paper towel
moistened with a common household detergent. Use a soft brush to clean
(lengthwise) the carbon filament on the front of the outlet grill. Make sure not to
damage the carbon filament during the cleaning process.
C. Cleaning the area around the unit
Wipe the area around the unit once a week with a wet paper towel. This will
prevent unmanageable debris from collecting.
CLEANING

GB
9
Mains 230-240 V / 50 Hz / 20 W
Current: 0,17 Amps
Installation No installation required.
Plugs into any electrical outlet.
Controls Control switch:
Off / high speed with ionization
/ low speed with ionization.
When the light goes on, the
unit is in operation.
Power Consumption High blower speed: 20 watts
Low blower speed: 12 watts
Airflow rates High speed: 85 m3/h
Low speed: 50 m3/h
Ionization
Total negative ion output:
2.5 x 1012 = 2.5 billion negative ions per second.
Minimum of 1000 negative air ions per cm3 in an area of 4 m x 6 m (= 24 m2).
Ionization voltage: 6kV
Ionization voltage has been optimally selected. It will provide an ample supply of negative
ions in the room and at the same time minimize deposits of pollutants in the immediate
vicinity of the unit.
Short current to ground is less than 0.1 milliamperes.
Direct contact with the carbon ionizing filament is completely safe.
Ionoscope Ion detector is provided with the unit.
Ozone 50% lower than UL safety limits.
Effective range up to 6 meters
Coverage 24 m2
Dimensions Length: 284 mm
Width: 227 mm
Height: 150 mm
Net Weight 1.4 kg
Safety
Complies with strictest standards: British Electrical Safety Standard BS3456 (UK), UL (USA)
and GS (Germany).
EEC Directives
Meets EEC directive 93/68/EEC (EMC) on electro-magnetic
compatibility and EEC directive 73/23/EEC (LVD) on safety.
TECHNICAL DATA
CLEANING
* Suject to change without notification

TC
10
一般安全手則
如果電線遭到磨損
或切壞時
小孩可能人看管
的地方。
被置於倒的
斜面或不平表面
靠近明火,易生
火的地方
切勿自己手修理
本品
可能有水滴落的地
方
暴露於室外天的
地方
在永久性非常
的境中
延源可能超
遭到 可能遭到化
物品的地方
有物干的危地
方
出於安全考慮,操作前請詳細閱讀本說明書。
不熟悉本說明書的人不得使用本產品。
强烈推荐保留本說明書,以備日後參考。
切勿在下列條件下使用空氣淨化機:
感謝您!
本說明書的目的在于使您熟悉您的AM4-0空氣淨化機的安装、操作与保養。敬請
詳细閱讀本說明書,并按照建議進行操作,确保可以無誤地操作AMCOR產品。
對於维修本產品,AMCOR是最為熟悉的。請不要自行打開、修理或清洗内部零
件,否則會失去保用服務。
感谢您購買AMCOR產品,并保證您可以不斷地體驗本產品所带来的舒适与满
意。