Albalá Ingenieros, S.A. TLE2001C01 User manual

TLE2001C01
ETHERNET ADVANCED COMMUNICATIONS CONTROLLER WITH SNMP
AGENT
Version 1.0
Albalá Ingenieros, S.A.
Medea, 4 - 28037 Madrid - Spain
16 December 2014 - © Albalá Ingenieros S.A. - All rights reserved

TLE2001C01

TLE2001C01
ETHERNET ADVANCED COMMUNICATIONS CONTROLLER WITH SNMP AGENT
Version 1.0
1. DESCRIPTION ...................................................................................................................... 5
1.1. The TLE2001C01 ............................................................................................................................. 5
1.2. Features ............................................................................................................................................. 6
1.3. Block diagram .................................................................................................................................. 7
2. SPECIFICATIONS ................................................................................................................. 9
3. INSTALLATION .................................................................................................................. 11
3.1. Initial inspection .......................................................................................................................... 11
3.2. Safety instructions ...................................................................................................................... 11
3.3. Environmental considerations ................................................................................................ 12
3.4. Installing the module in the mounting frame ................................................................... 12
3.5. Interconnection ............................................................................................................................ 13
4. OPERATION ...................................................................................................................... 15
4.1. Front panel description .............................................................................................................. 15
4.2. Functional description ............................................................................................................... 16
4.3. User and IP configuration ......................................................................................................... 16
4.4. Event logging application ......................................................................................................... 17
4.4.1. eventos.conf file structure ............................................................................................... 18
4.4.2. log file structure .................................................................................................................. 19
4.5. SNMP application ........................................................................................................................ 20
4.5.1. Agent characteristics ......................................................................................................... 20
4.5.2. MIB parameter types and structure ............................................................................. 20
4.5.3. Characteristics of the traps ............................................................................................. 21
4.5.4. snmpd.conf file structure ................................................................................................. 22
4.6. Redundant operation ................................................................................................................. 22
4.7. Module configuration and management utilities ........................................................... 22
4.7.1. File editing via FTP .............................................................................................................. 23
4.7.2. Review of the event logs stored ..................................................................................... 24
4.8. Module remote control and supervision ............................................................................. 26
4.8.1. The TL2000 protocol .......................................................................................................... 27
4.8.2. Details of the TLE2001C01 registers ............................................................................ 29
5. GLOSSARY ........................................................................................................................ 33
6. REGULATIONS .................................................................................................................. 35

7. VERSIONS ......................................................................................................................... 37

Albalá Ingenieros | Manual TLE2001C01
1. DESCRIPTION
1.1. The TLE2001C01
The TLE2001C01 module is an advanced communications controller for use with the
TL2000 family of modular systems from Albalá Ingenieros. This module enables
communication with the majority of TL2000 family modules over an Ethernet LAN as
long as the modules are capable of remote control and are installed in a mounting
frame. The more advanced modules require a TLE2001C02 communications controller to
be installed in the same mounting frame.
The TLE2001C01 module provide four general purpose terminals that can be
independently configured as inputs or outputs and whose status can be controlled from
a computer.
Two TLE2001C01 modules can be installed in the same mounting frame in order to
provide redundancy.
In addition to acting as the communications bridge between TL2000 family modules
located in the same mounting frame or exterior to the mounting frame, the TLE2001C01
can perform the following functions:
-Remote control of any TL2000 family modules from Albalá Ingenieros with this
feature using an internal SNMP agent.
-Supervision of all modules installed in the same mounting frame and logging of any
status change of the modules. In addition, notification of the changes can be sent to
a computer using the UDP protocol.
The TLE2001C01 is a TL2000 terminal line module and can be housed in a two rack unit
(2 RU) UR2000 mounting frame.
5

Albalá Ingenieros | Manual TLE2001C01
1.2. Features
• Communications controller module that provides:
- One 10/100Mbit/s Ethernet port for connection to a LAN.
-One high speed internal serial port for communication with all modules within the
UR2000 mounting frame using its internal data bus.
• Ethernet communications are established via TCP/IP and UDP/IP protocols.
• Four general purpose contacts that can be configured as inputs or outputs.
•Two TLE2001 modules can be installed in the same mounting frame in a redundant
configuration.
•Built-in SNMP agent for remote management of all TL2000 modules with remote
control capability.
•Optional recording to a log file of the status changes of the modules installed in the
same mounting frame and also notification to one or more computers via UDP.
• Low power.
6

Albalá Ingenieros | Manual TLE2001C01
1.3. Block diagram
7

Albalá Ingenieros | Manual TLE2001C01
TLE2001C01
8

Albalá Ingenieros | Manual TLE2001C01
2. SPECIFICATIONS
Ethernet interface
Connector RJ45
Encoding and electrical characteristics:
100BASE-T According to IEEE std 802.3u standard
10BASE-T According to IEEE std 802.3i standard
Operating modes Auto-Negotiation speed,
full duplex/half duplex
Supported protocols IP, ARP, ICMP, TCP, UDP, NTP, TELNET,
FTP, HTTP, SNMP
GPI input
Connector Plug-in terminal,
3.81mm pitch
Type 220 kΩ pull-up to 3.3 V
Number of inputs 4
Threshold levels:
VIH min. 2.3 V
VIL max. 0.5 V
Activation Closing contact to ground
Allowed voltage range -0.5 .. 60 V
GPO output
Connector Plug-in terminal,
3.81mm pitch
Type Open/closed drain
Number of outputs 4
Allowed voltage range -0.5 .. 60 V
General
Power consumption 1.6 W
Operating temperature range 0 .. 50 °C
Approximate weight 150 g
9

Albalá Ingenieros | Manual TLE2001C01
TLE2001C01
10
Table of contents
Other Albalá Ingenieros, S.A. Controllers manuals
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions