INSTALLATION
CAUTION — TIPS FOR REMOVAL OF OLD SHOWER:
Always turn off water supply before removing existing diverter or disassembling the valve.
Open shower handle to relieve water pressure and ensure all water has been drained.
Option 1: Easy Install(No drilling required)
2
7
T-12
1
Remove the existing showerhead
arm by turning it in a counter
clockwise direction.
Note: A channel lock wrench T-12
(Not included) may be required.
Prepare for installation.
ss than 1 -3/8"
1-7/8"-4"
Choosing the correct length of
shower arm.
Measure the distance between the
1/2" - 14 NPT (National Pipe Thread) in
wall water supply elbow (not included)
and the nished wall surface. If the
measurement is less than 1-3/8" choose
6" shower arm (1). If the measurement
is between 1-7/8"-4" choose 8" shower
arm (2).
1
If the wall surface is the same between
the shower arm and the bottom
mounting brocket, use 6" Shower
Arm (1).
2
If installing in a berglass or acrylic
shower enclosure where the shower
arm is mounted on sheet rock or tile,
use 8" Shower Arm (2).
6" Shower Arm
8" Shower Arm
1
2
There are two optional shower arm
for your choosing: 6" Shower Arm (1)
and 8" Shower Arm (2).
3
56
4