acaia AL010 User manual

Acaia Lunar
User Manual
AL008 / AL009 / AL010
FW 1.0.009

In the Box
Introduction
Scale Overview
Getting Started
Placement
Power On/Off
Tare Weight
Switch Mode
Product Care Information
Battery Charge
Battery Level Indicator
Calibration
Care and Cleaning
Flow-Rate Indicator
Brewing with Flow-Rate Indicator
Tare Save
Mode Introduction
Mode 1 - Weighing Mode
Mode 2 - Dual Display Mode
Mode 3 - Timer Starts with Flow Mode
Mode 4 - Auto-Tare Timer Starts with Flow Mode
Mode 5 - Auto-Tare Auto-Start Timer Mode
Mode 6 - Auto-Tare Mode
Conguration
Appendix
Buttons
LED Indicators
Error Codes
Other
Specications
3
3
3
4
4
4
4
4
5
5
5
5
5
6
7
8
9
9
9
10
11
12
13
15
20
20
21
22
22
23
Contents

Next, follow the instructions in Getting Started to begin using your scale. To take full
advantage of the Lunar’s many features, carefully read through the manual, which contains
step-by-step procedures, examples, and other information.
Warning: Incorrect handling of this product could result in personal injury or physical damage.
Thank you for choosing our scale. The Acaia Lunar is designed and manufactured to the
most rigorous standard to give you the best coffee brewing experience. Start by checking
your Acaia Lunar box to nd the following:
*Note: For the best performance, place the weight in the center of the weighing pan.
In the Box
Introduction
Scale Overview
Weighing Pan
LED Display
Power Button Tare Button
Acaia Lunar Heat Resistant Pad USB Type-C
Charger Cable
Acaia Calibration
Weight 100 g
3

Getting Started
Placement
Power On/Off
Tare Weight
Switch Mode
Place the scale on a stable and vibration-free surface at a preferably
horizontal location.
4
[Press] to turn on the scale.
[Double tap] to turn off the scale.
[Press] to tare/zero the weight.
[Press and hold] to switch modes.
* Please see the “Mode Introduction” section for more details.

• You can charge the battery by plugging the USB cable into any
of the power supplies listed below:
• A computer
• A USB wall-charger with an output of 5 volts and 1 amp
• A DC car-charger with an output of 5 volts and 1 amp
• It takes about 1-2 hours to fully charge the battery from
empty. Try not to let the battery completely run out before
charging. Charge as needed.
• To check remaining battery level, see below for Battery Level
Indicator.
• When powering off the scale, the Battery Level Indicator can be seen on the top of the display.
• You can also check the battery level in the main settings menu. When the scale is powered
off, press and hold the Power button, the LED display will show [ ACAIA ] and then changes
to [ SEt ]. Continue holding the Power button until the battery percentage is displayed.
• You can also check the battery level by connecting the scale to Acaia Apps.
Product Care Information
Turn on the Acaia
scale.
Turn on scale
Make sure the scale
is in weighing mode
and the unit is set to
‘gram’, then tap the
‘T’ button rapidly.
Tap T button
Keep tapping the ‘T’
button until ‘CAL’ is
shown on the
display.
See CAL display
Place a weight on the
scale and wait until the
display shows ‘_End_’.
Calibration is now
complete!
Place a weight
Battery Charge
Calibration
Care and Cleaning
5
Battery Level Indicator
When powering off When accessing settings
Note: You may also use 500 g, 1000 g or 2000 g weights. If you use weights other than Acaia
Weights, we recommend F2 class standard calibration weights.
• Use a soft cloth with warm water only to clean the product.
• Do not use detergent or other chemicals for cleaning and soaking as it can damage the
anodized coating on the product.

Flow-Rate Indicator
The Flow-Rate Indicator is an LED bar on the top of the display. It helps you visualize your
espresso ow-rate in real time and spot channeling during brewing. The indicator measures
ow-rate with lit LEDs starting from 0.1 g per second on the left to 3.4 g per second on the right.
When the ow-rate exceeds 5.0 g per second, the last three LEDs will light up with enhanced
brightness, indicating a high ow-rate. During an espresso brew, the Flow-Rate Indicator will
display the highest peak ow-rate of this brew with a single bright LED.
The Flow-Rate Indicator can be activated in all modes. You can turn the indicator on or off in the
advanced settings menu.
You can also enable markings on the Flow-Rate Indicator for easier reading of the ow-rate
value. Each marking indicates an increment of 0.5 g/s for the current ow-rate, and the highest
marking is 4.0 g/s.
Note: To enable this function, please see Flow-Rate Indicator in the Conguration section (p.15).
6

Place a cup on the scale to start brewing.
During an espresso brew, the Flow-Rate Indicator will
display the highest peak ow-rate of this brew with a
single bright LED.
The highest peak ow-rate LED will stay on the display
during an espresso brew.
When brewing is completed, the highest peak ow-rate
LED will stay on the display.
When brewing is completed and the cup is removed
from the scale, the display will ash to show the nal
beverage weight and the average ow-rate of the
brewing. The Flow-Rate Indicator will show the average
ow-rate with a stripe LED and the highest peak
ow-rate with a single bright LED.
7
Brewing with Flow-Rate Indicator
The highest peak & Real ow-rate
The highest peak ow-rateReal ow-rate
Average ow-rate
The highest peak ow-rate
The highest peak ow-rate
The highest peak ow-rate

Tare Save
If you have a frequently used container in your weighing workow, you can save the weight of the
container using the Tare Save function. This will allow you to weigh the container with contents,
then trigger Tare Save to deduct the container weight and obtain the net weight. The Tare Save
function can be activated in Weighing mode and Dual Display Mode.
Save Container Weight
Tare Container Weight Using Tare Save
Place a container on the
scale.
Place a container along
with its contents on the
scale.
Press and hold Tare
button for 2 seconds
when reading is stable.
The weight is stored
as a preset container
weight.
Press and hold Tare
button for 0.5 second.
The scale will display
the weight to be
deducted.
You may continue using
your scale.
The net weight is displayed
on the scale.
Action Operation
Save Container Weight Press and hold Tare button for 2 seconds
Subtract Container Weight Press and hold Tare button for 0.5 second
8
• To save a new container weight, place the desired container on the scale, then press and hold
Tare button for 2 seconds. This will register a new preset container weight.
• It is only allowed to tare container weight once, if you press and hold Tare button for 0.5 second
again, the scale will display [ CUP ] and the preset container weight, but the cointainer weight will
not be tared again.
1
1
2
2
3
3

In the Weighing Mode, the scale will only display weight,
in either grams or ounces.
In the Dual Display Mode, the scale displays [ 0:00 0.0 ]
with a timer (left) and weight (right).
• There are two different weighing units in Weighing Mode: gram and ounce.
• In grams, the LED display shows [ 0.0 ].
• In ounces, the LED display shows [ 0.000 ] and the Weighing In Ounces Indicator on the
bottom left lights up.
• The readability is 0.1 g or 0.002 oz. For high resolution mode, the readability is 0.01 g or
0.0005 oz.
• The Tare Save funtion is supported in this mode.
• There are two different weighing units in Dual Display Mode: gram and ounce.
• In grams, the LED display shows [ 0:00 0.0 ].
• In ounces, the LED display shows [ 0:00 0.000 ].
• The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.
• The Tare Save funtion is supported in this mode.
Mode Introduction
Mode 1 - Weighing Mode
Mode 2 - Dual Display Mode
Action Operation
Tare Weight Tap Tare button
Switch Mode Press and hold Power button
Action Operation
Start/Stop/Reset Timer Tap Power button
Tare Weight Tap Tare button
Switch Mode Press and hold Power button
9
Note :
To change the weighing unit to either gram or ounce, please see Default Unit Setting in the
Conguration section (p. 15).

• In grams, the LED display shows [ 0:00 0.0 ].
• In ounces, the LED display shows [ 0:00 0.000 ].
Mode 3 - Timer Starts with Flow Mode - Droplet
Mode Description
Display
Action Operation
Start Timer The timer will start when the ow is detected
Tare Weight Tap Tare button
Stop Timer The timer will stop when ow is no longer detected
Reset Mode Double tap Tare button
Switch Mode Press and hold Power button
When the scale detects the ow of espresso, the timer
starts. The timer will stop when the ow stops.
*Please note: The ow detection mode is designed to
detect the slow trickle of a shot of espresso. The timer
may not trigger when attempting to pour from a kettle.
10
• The timer starts when the ow of espresso is detected.
• When the espresso ow stops, the timer stops.
The droplet icon indicates that you
are in Timer Starts with Flow Mode.
The timer starts when the ow of
espresso is detected.
Place a cup on the scale and tare
the weight manually.
The timer will stop automatically
when the espresso ow stops or the
cup is removed.
1
3
2
4
This manual suits for next models
3
Table of contents
Other acaia Scale manuals

acaia
acaia Pearl User manual

acaia
acaia Coffee Scale User manual

acaia
acaia Pearl Specification sheet

acaia
acaia lunar Installation manual

acaia
acaia Pyxis User manual

acaia
acaia Pearl User manual

acaia
acaia AC001 User manual

acaia
acaia PS001 User manual

acaia
acaia lunar User manual

acaia
acaia lunar User manual