ZKTeco V4L User manual

Overview1Power InGND12VEthernetTX+RX+TX-RX-AL+AUX485AIWD1BELL-GNDGND+12VGNDIWD0WD0WD1485BBELL+AL-NC
COM
NOBUTGNDSENGNDRS485LockAlarmAuxiliaryInputWiegandOutWiegandInBellExit ButtonSensor4-inch TouchscreenMicrophoneCard Reading Area ResetSpeakerDoorbell ButtonUSBNear-infrared FlashThermal Imaging TemperatureDetection ModuleFlashCamera & Palm CollectorNote: Not all products have the function with , the real product shall prevail.

Recommended Palm GesturesNote:1. Place your palm within 30-50 cm of the device.2. Place your palm in the palm collection area, such that the palm is placed parallel to the device.3. Make sure to keep space between your fingers.
3
KEEP EFFECTIVEDISTANCE OF30-50 cmKEEP SPACESBETWEENYOUR FINGERSDO NOT KEEPYOUR FINGERSCLOSEDO NOT KEEPPALM OUTSIDECOLLECTION AREADO NOT KEEPYOUR FINGERSFOLD/CURLEDInstallation Environment
INSTALL INDOORSONLY
Please refer to the following recommendations for installation.AVOID DIRECT SUNLIGHT AND EXPOSUREAVOID INSTALLATIONNEARGLASS WINDOWSAVOID USE OF ANYHEAT SOURCENEAR THE DEVICEKEEP EFFECTIVEDISTANCE OF0.3m-2mRecommended Standing Position2

Forehead Temperature DetectionInstallation height: 1.55mFOV (Field Of View) of the thermalimaging device: 50°
Temperature detection distance: 0.3m to 1.2mHeight of the face adapted fordetection: 1.2m to 2m155CMSpecificationStandard valueRemarkOperating EnvironmentDistance (between face and device)Measurement AccuracyIndoor, Avoid wind, Avoid direct sunlight,16°C to 35°C (60.8°F to 95°F)30cm to 120cm (0.98ft to 3.94ft)±0.3°C (±0.54°F)The recommended operating temperature is 25°C (77°F)The recommended distance is 80cm (2.62ft)This value is tested at a distance of 80cm or 2.63ft under 25°C(77°F) environment.Note: The temperature measurement data is only for reference, and not for any medical purposes.Installation RequirementsThe installation requirements and indications associated with the device are given below:Indoor constant TemperatureEnvironment3

4
TCP/IPAlarmSmoke DetectorLockExit ButtonDoor SensorCard ReaderStandalone InstallationPower Connection12V DCGNDGND12VRecommended AС Adapter1) 12V ± 10%, at least 3000mA.2) To share the power with other devices, use an AС Adapter with higher current ratings. ZKBioAccess IVS

5Ethernet ConnectionClick [COMM.] > [Ethernet] > [IP Address] , input the IP address and click [OK].Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioAccess IVS software.IP address: 192.168.1.130Subnet mask: 255.255.255.0876RJ 4554321TX+TX-RX+RX-Default IP address: 192.168.1.201Subnet mask: 255.255.255.0ZKBioAccess IVSDoor Sensor, Exit Button & Alarm ConnectionAL+NC
COM
NOGNDAL-BUT
AUX
SENGND485AIWD1IWD0485BBELL+BELL-GNDGNDDoor SensorExitButton
+
-
Smoke Detector
-+
Alarm's Power Switch
+-
AlarmCOMNO

DC12VLock Relay Connection61) Device not sharing power with the lockAL+485AIWD1+12VGNDIWD0485BNC
COM
NOGND+12VGNDFR107Normally Closed LockDC12V2) Device sharing power with the lockNormally Closed LockAL+485AIWD1+12VGNDIWD0485BNC
COM
NOGND+12VGNDFR107The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (normally opened when powered) is connected with 'NO1' and 'COM' terminals, and the NC Lock (normally closed when powered) is connected with 'NC1' and 'COM' terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below:DC12V

AL+485AIWD1IWD0485BNC
COM
NOGND7 RS485 ConnectionWiegand Reader ConnectionWiegand card reader connects to the top 4 pins of the wiegand terminal and the last two pins are used by the Access Controller, as shown in the following figure. It sends the credentials to the device via wiegand communication.The RS485 lets user connect to multiple readers to the device. RS485 can be connected to the terminal, as shown in the figure below. GND485+485-Wiegand Reader+12VIWD1IWD0GND+12VGNDWD0WD1 RS485 ReaderAccess Controller WD0 WD1

User RegistrationMethod 1: Register on the deviceWhen there s no super administrator set in the device, click on enter the menu. i toAdd a new user and set User Role to Super Admin, then thethe system will request foradministrator’s verification before entering the menu. It is recommended to register asuper administrator initially for security purposes.Click on > [] > [] to register a new user. The options include User Mgt.New Userentering the User ID and Name, setting User Role, registering Palm, Face, Card Number, Password and adding Profile Photo.User Mgt.New UserAll UsersDisplay StyleWelcome2021-04-29 14:31Thursday2021-04-29LEnroll FaceEnrolled SuccessfullyPalm RegistrationEnrolled Successfully1111*****1New UserUser IDNameUser RolePalmFaceCard NumberPasswordProfile PhotoAccess Control RoleNormal UserMike8Main MenuUser Mgt.User RoleCOMM.SystemData Mgt.PersonalizeUSBManagerAutotestSystem InfoAccess ControlLAttendance Search

9Method 2: Register on ZKBioAccess IVS softwarePlease set the IP address and cloud service server address in the Comm. Menu option on the device.Search DeviceSearchNo device found? D ownload Search Tools to Local DiskDevice TypeSerial NumberTotal ProgressSearched devices count:1IP AddressIP AddressMAC AddressSubnet MaskGateway AddressSerial NumberDevice TypeSet ServerOperations192.168.213.79255.255.255.0192.168.213.1AddThe current systen communication port is 6609, please make sure the device is set correctly.CloseRefreshNewDeleteExportSearch ControlSet upView / Get CommunicationStep 1Step 2Step 3AddDevice Name Icon TypeAreaAdd to LevelClear Data in the Device when Adding[Clear Data in the Device when Adding] will delete data in the device(except eventrecord), please use with caution!OKCancel192.168.213.79DoorArea NameStep 4Note: If the device has optional dynamic QR code function, you need to use the ZKBioSecurity to connect the device and perform the corresponding operation to support the QR code function.For more details, please refer to the ZKBioAccess IVS User Manual.Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device.Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.Click [Access] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.2.3.4.Click [Access] > [Access Device] > [Device] > [Search] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.1.
Table of contents
Popular Laboratory Equipment manuals by other brands

Agilent Technologies
Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser
Endress+Hauser Cleanfit CPA875 operating instructions

NI
NI PXI-5422 CALIBRATION PROCEDURE

Collomix
Collomix Aqix operating instructions

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight
Ocean Insight FLAME-NIR+ Installation and operation manual

Parker
Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD
BD 644787 user guide

DENTAURUM
DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 instruction manual

VWR
VWR SAS Super IAQ instruction manual

illumina
illumina MiSeqDx reference guide