Zimmer enPulsPro User manual

User Manual
enPulsPro
USA


Illustrations
Front of the device
Fig. 1
Selection and
operating elements
1 Control unit
2 Pulse energy controller
3 Display
4Frequency controller
5Slot for SD card
6Power switch
Handpiece
7 Handpiece
8 Vent, front
9 Vent with fan, rear
10 Holder for hand piece
Footswitch
11 Footswitch
Optional
accessories
12 Rotatable swivel base
2
5
7
8
4
3
10
11
1
9
12
6

Illustrations
Rear of the device
Fig. 2
Switches /
Connector sockets
13 Socket for mains cable
14 Mains fuse
15 Socket for handpiece channel I
16 Socket for handpiece channel II
17 Socket for footswitch
18 Identification plate
16
15
17
13
18
14

Illustrations
Screens / Displays
Fig. 3
Displays / Therapy
screen
19 On-screen buttons
20 Status bar
21 Navigation bar
22 VAS- Pre scale
23 VAS- Post scale
Fig. 4
Navigation bar
Description of the
functions
(A) Back
Takes you back one step
(B) Therapy
Switches to the therapy screen
(C) History
(D) Protocols
Switches to the VAS evaluation
Switches to protocols
(E) Programs
Switches to the program list
(F) Favorites
Switches to the favorites area
21
19
20
F
E
D
C
B
A
22
23

Illustrations
Applicator heads and accessories
Fig. 5
Applicator heads
24 Applicator head, 25 mm
25 Applicator head, 15 mm
26 Applicator head, 6 mm
Accessories
27 Silicone protection cap
24
25
26
27

Explanation of Symbols
In the instructions for use, this symbol indicates danger.
Caution!
In the instructions for use, this symbol indicates a "Caution" with regard to
possible damage of the device.
Socket for handpiece
Socket for footswitch
User Manual
Follow user manual
Serial number
Article number
Manufacturer
Date of manufacture
Applied part type BF
Value of accessible fuses
Interval operation - Follow user manual

Contents
Illustrations
Front of the device
Rear of the device
Screens / Displays
Applicator heads and accessories
Explanation of Symbols
Page
1
Indications / Contraindications
1
2
Side Effects
2
3
Application Information
3
4
Warnings
4
5
enPulsPro –in brief
6
6
Device Set-Up
7
7
Settings
8
8
Operating Instructions
8.1 Device Description
8.2 Notes on Operation
8.3 Performing the Treatment
8.4 Display and Buttons
8.5 SD card
8.6 Favorites List –Retrieving Programs, Editing Lists
8.7 VAS –Visual Analogue Scale
10
12
13
14
16
17
20
9
Technical Information
9.1 Info-Chart Duration of Treatment
24
26
10
Cleaning / Disinfection
27

Contents
11
Scope of Delivery and Accessories
31
12
Device Combination
32
0
13
Safety and Maintenance
13.1 Safety
13.2 Maintenance
33
34
14
Functional Test
35
32
15
Safety Check / Metrological Control
36
16
Error Messages / Troubleshooting / Disposal
37
17
Manufacturer´s EMC Declaration
39
Valid for the device enPulsPro (NG).
This user manual is an integral part of the device.
It must be stored with the device and kept accessible at all times for anyone authorized to
operate this device. Full observation of these instructions is a requirement for the correct
application and operation of the equipment and for consequent safety for patient and
operator.
The user manual is valid as of September 2019.
U.S.A. Federal Law restricts this device to sale by or on the order of a practitioner
licensed by the law of the State in which he/she practices to use or order the use of
the device.

Indications / Contraindications
1
Page 1
Indications
For relief of minor muscle aches and pains and for temporary increase in
local blood circulation.
Contraindications
vascular diseases present in or near the treatment area
local infections in the treatment area
around malignant or benign tumors
directly on cartilage surfaces or near the small facet joints of the spinal
column
directly over implanted electronic devices such as pacemakers, analgesic
pumps, etc.
in areas, in which mechanical energy in the form of vibrations may lead to
tissue damage such as metal implants after a fracture
In general we advise against treatments
if blood clotting disorders are present or the patient is receiving treatment that
results in a change in the blood clotting behavior
during pregnancy
on patients with neurological diseases resulting in impairment of the
vasomotor function in the treatment area
over air-filled cavities such as treatment on the thoracic spine, etc.
on children, particularly around the epiphyseal plates
Care is required for patients
with impaired sensibility
with severe autonomic disorders
under the influence of drugs and/or alcohol
as circulatory stresses and inadequate treatment responses cannot be
excluded.
Other manuals for enPulsPro
3
Table of contents