XtendLan XL-RAID133v2 User manual

XL-RAID133v2
Data Backup System
User’s Guide

Contents
Chapter1Introduction............................................................................................................................2
1‐1FunctionsandFeatures.................................................................................................................2
1‐2ProductSpecifications...................................................................................................................3
1‐3SystemRequirementsandsupport...............................................................................................3
1‐4Note(ReadcarefullybeforeusingXL‐RAID133v2).......................................................................4
Chapter2Installation..............................................................................................................................5
2‐1PackageContents..........................................................................................................................5
2‐2PartDescription.............................................................................................................................6
2‐3Howtoopen/closethefrontpanel...............................................................................................7
2‐4Howtoremove/inserttheRemovableCarrier.............................................................................8
2‐5InstallingHDDintheRemovableCarrier.....................................................................................10
2‐6InstallingtheXL‐RAID133v2inyourComputer...........................................................................10
Chapter3RAIDUse...............................................................................................................................11
3‐1FactoryDefault............................................................................................................................11
3-2 Installation...................................................................................................................................12
Chapter4LCDInformationList.............................................................................................................13
4‐1AutoRebuildingStatus................................................................................................................13
4‐2LCDdisplayshowingHDDstatus.................................................................................................14
Chapter5FirmwareUpdate...............................................................................................................16
Chapter6RAIDGuideSoftware.............................................................................................................17
6‐1Introduction................................................................................................................................17
6‐2HowtoInstall..............................................................................................................................17
Chapter7Questions&Answers............................................................................................................19
APPENDIX..............................................................................................................................................21
1

Chapter 1 Introduction
XL-RAID133v2 provide disks mirroring (RAID1) and striping (RAID0) functions for small
offices or home offices. XL-RAID133v2 is an excellent reliability and high-efficiency
solution for online back up or capacity expansion.
1-1 Functions and Features
Interface
"ATA133 E-IDE interface, up to 133MB/Sec.
"Supports 2 ATA133/ATA6 E-IDE Drive.
"Alarm for HDD failure, overheat and fan failure (XL-RAID133v2 only).
RAID
"Supports RAID 0, 1.
"The two hard disks can simultaneously perform mirroring for online backup or striping
for capacity expansion.
"One of the two hard disks can function as source, and the other as target for back up
purpose. (RAID 1)
"Providing on-line rebuilding function. (RAID 1)
"Hot swappable to replace damaged HDD without interrupting system. (RAID 1)
"Supports over 400GB Capacity. (RAID 0)
Enclosure
"Independent Operating Systems (OS), no drivers required.
"LCD screen showing HDD operating status.
"RAIDGuide GUI Software with E-mail notification Aluminum case (XL-RAID133v2
only).
"Fan failure and overheat detectors.
2

1-2 Product Specifications
Model No. XL-RAID133V2
System Specifications
Microprocessor 8032 microprocessor
Host Interface ATA133/UDMA133
Host Transfer Rate 133MB/sec
RAID level 0, 1
Installation Space 2 x 5-1/4” Expansion Bay
Drive 2 x ATA133/UDMA133 EIDE 1" Height
HDD Selection Mode Master/Slave
Support Big Drive Yes
Overheating prevention 8cm Ball Bearing Fan
Environmental Conditions
Operating Temperature 0°C~55Ԩ
N
on operating Temperature -20°C~70Ԩ
RAIDGuide GUI Software Yes
Reliability
Error Detector HDD, Overheat, Fan
Dimensions
Material Aluminum
Measures (mm) 146(W)X238(D)X85(H)
Weight 0.9 Kg (HDD Excluded)
Safety CE, FCC, BSMI Certificate
1-3 System Requirements and support
"Hardware Requirements
1. With IDE Interface Computer System.
2. HDD with standard EIDE/IDE Interface.
3. 2 x 5-1/4” Expansion Bay.
4. One 4-pin DC power socket outlet.
5. To be afford to offer two hard disk power consumption.
3

1-4 Note (Read carefully before using XL-RAID133v2 )
1. Use two identical hard disks (same brand name and model) for optimum performance
and greatest convenience.
2. To obtain optimum performance, use two brand new hard disks or hard disks in perfect
conditions without any damaged sectors.
3. Use hard disks with a minimum capacity of 3.2GB Ultra DMA 33/66.
4. Easy to use with hard disks manufactured by QUANTUM, IBM, MAXTOR, or Western
Digital, etc.
5. Whether it is the upper or lower deck, please set up both Hard Disks to MASTER mode
or else HDD won’t be detected.
6. If replacing an old HDD with a new one, please purchase the same brand and choose a
disk capacity greater than or equal to the original one.
7. XL-RAID133v2 will automatically format a new HDD as use the Auto-Rebuild
Function to copy data to the new target HDD.
8. Normal HDD mode for XL-RAID133v2 is Ultra DMA. In the event of failure to work
with EIDE connector, HDD will automatically configure itself in PIO mode 4 or with
lower speed.
9. There is a Ball Bearing Fan integrated in the XL-RAID133v2 to prevent overheating for
7200 rpm HDD. When two 7200rpm Hard Disks are installed in a very busy server, we
suggest adopting a PC case with optimal design for overheating prevention in order to
avoid PC or RAID crashes.
10. In case of power failure during the Auto-Rebuild Function, controller will remember
the rebuilding progress percentage and carry on the operations when the power is
restored.
Please decide RAID level before formatting hard drive. As once you complete RAID setup,
changing RAID level will lose all data in drive.
4

Chapter 2 Installation
2-1 Package Contents
Your XL-RAID133v2 package includes the following: please contact our distributors in
case of any missing or damaged items.
Item Quantity
RAID Kit 1
Removable Carrier in RAID 2
CD Box with express installation 1
Accessories bag 1 (including 8 x 6#-32 and 8 x M3×6 screws )
SR2Kplus RS232 Cable 1
SR2Kplus RS232 Flat ( Inner Cable ) 1
5

2-2 Part Description
Front Panel
Buzzer On/Off switch :
Alarm functions when buzzer switch is on. To release the function, please push the button. Push the button
again to recover the function.
LED displays Red when buzzer switch is Off.
6

Inside the XL-RAID133v2
Back Panel
2-3 How to open/close the front panel
"Opening the front panel
1. Touch the right side center of the front panel with your finger as indicated by the arrow.
There is a trigger to open the panel.
7

"Closing the front panel
1. Turn the panel in the direction indicated by the arrow to connect it with the trigger until it
clicks inside, which means the front panel is closed.
2-4 How to remove/insert the Removable Carrier
"Removing the Removable Carrier
1. Following the indicated direction, press down and hold the Removable Carrier Handle
to unlock the spring from its button.
2. Turn the Removable Carrier Handle in the direction indicated by the arrow to remove
the Removable Carrier.
3. Pull out the Removable Carrier along the direction shown in the figure.
8

"To insert the Removable Carrier
1. Following the direction indicated by the arrow, slide the Removable Carrier along the
rail into the slot end of the upper or lower deck.
2. Following the direction indicated by the arrow, turn the Removable Carrier Handle to
the end in order to fix it with the spring.
9
Table of contents
Other XtendLan Storage manuals

XtendLan
XtendLan xl-raid-2804issa Manual

XtendLan
XtendLan XL-SATA-MULTI User manual

XtendLan
XtendLan XL-RAID-213SA User manual

XtendLan
XtendLan XL-NAS-2800SS User manual

XtendLan
XtendLan XL-RAID4-USB3 User manual

XtendLan
XtendLan XL-RAID-SATA User manual

XtendLan
XtendLan XL-RAID-SATA2 User manual

XtendLan
XtendLan XL-NAS-500SA Operator's manual

XtendLan
XtendLan XL-RAID-2123ISSA User manual

XtendLan
XtendLan XL-RAID-526SA User manual



















