Wyrestorm TS-280-US User manual

IMPORTANT! Installation Requirements
• Visit the product page to download the latest rmware, document version,
additional documentation, and conguration tools.
• Read through the Wiring and Connections section for important wiring
guidelines before creating or choosing premade cables.
In the Box
1x TS-280-EU or TS-280-US
1x 4-pin Phoenix Terminal Block
1x CON-232-422 Touchscreen Interface Module
2x Mounting Brackets for interface module
1x MicroSD Card
1x MicroSD USB Adaptor
1x Quickstart Guide (this document)
Copyright © 2018 WyreStorm Technologies | wyrestorm.com
TS-280-US | TS-280-EU v1 Quickstart Guide | 181128
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
1 of 4
WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features before beginning the
installation process.
Basic Wiring Diagram
TS-280-US
Note: EU model also available, TS-280-EU.
Front Rear
Front Rear
CON-232-422
(Included)
WyreStorm HDBaseT
Receiver
SW-0401-HDBT
Amplifier
KEY
HDMI
RS-422/HDBaseT
IR/RS-232
Analog Audio
Power
Note: Separate 12V DC power
supply only required when
switcher does not supply power.
Not included with TS-280.
2.8” Serial Control Color Touchscreen
TS-280-US | TS-280-EU Quickstart Guide

Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read through this section in its
entirety before running or terminating any wires to ensure proper operation and to avoid damaging the equipment.
IMPORTANT! Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables, and electrical or environmental interference will have an adverse effect on signal
transmission which may limit performance. Steps should be taken to minimize or remove these factors completely during installation for best results.
Touchscreen Interface Module RS-232 Wiring
The touchscreen uses a separate component that connects to a WyreStorm switcher for RS-232 communication. This signal is converted to RS-422 for the
touchscreen itself. Connection on the CON-232-422 is a 4-pin phoenix which not only contains the pins for communication, it also contains a pin for power from
some of the currently available switchers. This can be used to power the converter from the switcher eliminating the need for a separate PSU. In the case of
3-pin connections on switchers, a separate PSU will be required.
Switchers with 4-pin RS-232 Connection
Pin 1 12V DC In ---> To ---> Pin 1 12V DC Out
Pin 2 TX (Transmit) ---> To ---> Pin 3 RX (Receive)
Pin 3 RX (Receive) ---> To ---> Pin 2 TX (Transmit)
Pin 4 G (Ground) ---> To ---> Pin 4 G (Ground)
Touchscreen Interfac
e Module
Switcher with 4-pin
Switchers with 3-pin RS-232 Connection
Pin 1 12V DC In ---> To --->
Pin 2 TX (Transmit) ---> To ---> Pin 2 RX (Receive)
Pin 3 RX (Receive) ---> To ---> Pin 1 TX (Transmit)
Pin 4 G (Ground) ---> To ---> Pin 3 G (Ground)
Touchscreen Interfac
e Module
Switcher with 3-pin
No Connection
Product Dimensions
TS-280-US Dimensions
Top
Front Right
117.0 mm.
4.6 in.
114.0 mm.
4.5 in.
32.1 mm.
1.3 in.
26.1 mm.
1.0 in.
56.0 mm.
2.2 in.
57.6 mm.
2.3 in.
43.2 mm.
1.7 in.
TS-280-EU Dimensions
147.0 mm.
5.8 in.
86.0 mm.
3.4 in.
32.1 mm.
1.3 in.
56.0 mm.
2.2 in.
57.6 mm.
2.3 in.
43.2 mm.
1.7 in.
Top
Front Right
26.1 mm.
1.0 in.
Copyright © 2018 WyreStorm Technologies | wyrestorm.com
TS-280-US | TS-280-EU v1 Quickstart Guide | 181128
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
2 of 4

Troubleshooting
Touchscreen not Powering On
• Verify that power is being supplied to the CON-232-422 either via power
from the switcher on the RS-232 connection or a separate 12V DC PSU (not
included).
• Verify that the category cable between the CON-232-422 is properly
terminated following EIA568B standard.
• Verify that the cable between the switcher and the CON-232-422 is properly
terminated following the Wiring and Connections section.
File Fails to Upload
• Ensure the .tft le is loaded to the root folder of the MicroSD card.
• Other folders may be stored to the MicroSD card but only the .tft UI le can
exist in the root folder.
Touchscreen not Controlling Switcher
• Verify that the category cable between the CON-232-422 is properly
terminated following EIA568B standard.
• Verify that the cable between the switcher and the CON-232-422 is properly
terminated following the Wiring and Connections section.
• Verify that the appropriate UI le for the switcher was downloaded and
installed on the touchscreen.
Troubleshotting Tips
• WyreStorm recommends using a cable tester or connecting the cable to
other devices to verify functionality.
Copyright © 2018 WyreStorm Technologies | wyrestorm.com
TS-280-US | TS-280-EU v1 Quickstart Guide | 181128
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
3 of 4
Setup and Conguration
1. In any browser Go to wyrestorm.com and navigate to the TS-280 product page
2. Scroll down and click on User Interfaces under Downloads.
3. Select the appropriate UI le for the product being installed and download the le.
4. Once downloaded, unzip the contents to ensure they are available for the next steps.
5. Insert the microSD card into the USB reader and connect to a PC or Mac.
6. Select the appropriate xxxx.tft le based on the actions required for the installation and copy to the MicroSD card drive.
7. Once the le has downloaded, eject the MicroSD card from the PC/Mac and remove from the reader.
8. Insert the MicroSD card into the card slot located on the rear of the touchscreen.
9. Connect the CON-232-422 to the switcher or a PSU. If connecting to a switcher, power on the switcher.
10. Connect the touchscreen to the CON-232-422. Once connected the download will begin.
11. The screen will show the progress and indicate when it is complete. Once completed and veried, disconnect the screen from the CON-232-422 and/or the
PSU from the CON-232-422 and ensure the MicroSD card is removed.
12. The touchscreen is now ready to be installed and used with the switcher.

Copyright © 2018 WyreStorm Technologies | wyrestorm.com
TS-280-US | TS-280-EU v1 Quickstart Guide | 181128
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
4 of 4
Warranty Information
WyreStorm Technologies LLC warrants that its products to be free from defects in material and workmanship under normal use for a
period of ve (5) years from the date of purchase. Refer to the Product Warranty page on wyrestorm.com for more details on our limited
product warranty.
Specications
Note: WyreStorm reserves the right to change product specication, appearance or dimensions of this product at any time without prior notice.
Touchscreen Touchscreen Interface Module
Audio and Video
Switcher Control 1x RS-422: 8-pin RJ-45 Female 1x RS-232: 4-pin Phoenix
Max Communication Distance 100m/328ft Interface to Touchscreen 15.24m/50ft Switcher to Interface
Power
Power Supply 12VDC from Touchscreen Interface Module 12V DC from switcher or separate PSU (not included)
Max Power Consumption 0.84W 0.36W
Environmental
Operating Temperature 0 to + 45°C (32 to + 113 °F), 10% to 90%, non-condensing
Storage Temperature -20 to +70°C (-4 to + 158 °F), 10% to 90%, non-condensing
Maximum BTU Transmitter: 24 BTU/hr | Receiver: 58 BTU/hr
Dimensions and Weight
TS-280-US TS-280-EU
Rack Units/Wall Box 2 Gang 2 Gang <1U
Height With | Without Feet 114mm/4.49in 86mm/3.39in 25mm/0.99in
Width With | Without Brackets 117mm/4.61in 147mm/5.79in 80.2mm/3.16in
Depth With | Without Handles 32.1mm/1.27in 32.1mm/1.27in 50mm/1.97in
Weight 0.30kg/0.66lbs 0.28kg/0.62lbs 0.14kg/0.30lbs
Regulatory
Safety and Emission CE | FCC | RoHS
This manual suits for next models
1
Other Wyrestorm Touchscreen manuals
Popular Touchscreen manuals by other brands

Elecro Engineering
Elecro Engineering Poolsmart Plus Installation & operating manual

Johnson Controls
Johnson Controls IQ4 HUB installation manual

Elo TouchSystems
Elo TouchSystems ET2270L user manual

Elo TouchSystems
Elo TouchSystems ET1002L user manual

Elo TouchSystems
Elo TouchSystems 3201L user manual

Duratec
Duratec S15 user manual