1. Listing. Shape and Panel Key Description
1.1 Packing list
No. Name QTY
1 LIFT SYSTEM 1PCS
2 POWER CABLE 1PCS
3 RS458 CABLE 1PCS
4 USER MANUAL 1PCS
1.2 Panel key functions
图FIG1 panel surface
FIG2 Extended Button show
UP/DOWN /STOP Button
USB Spare

1.2.1 Out connect USB input(FIG2).
1.2.2 Spare PC switch button:PC SW,it match with the connector
input on the back connector board.
1.2.3 Spare image switch button:SA SW, it match with the
connector input on the back connector board.
1.2.4 One key to operate(FIG3):Three kinds state of circulation,UP
STOP DOWN。Blue Indicator light display the control board
is on 5V working condition.
FIG3UP/DOWN /STOP Button
1.3 Interface board features(from left to right)
FIG4 Signal connector board surface
1.3.1 HDMI input( Standard).
1.3.2 VGA input (for options)
1.3.3 DIV input (for options)
1.3.4 USB input:1)Up USB for data ,match with top panel USB input to
connect with computer USB port. 2) Down USB for touch screen
control input, it’s must connect with computer USB port, then can
use the touch screen function.
1.3.5 RS485 control input(1,2,5)
Power
Radio remote

1.3.6 RS485 control output(group control)
1.3.7 Spare button connector port: match with top panel PC SW button,
SA SW video signal SW button.
1.3.8 Radio remote control Antenna(433.92MHz)
1.3.9 Power input(AC 220V /10A 50/60Hz)on the right side.
1.4 Screen button function instruction on the back side of lifter.
1.4.1 Screen button Manu function(Vertical installation mode)
FIG6 Screen Menu button
“Menu” menu button,
“Auto” Automatic adjustment key,
“
▲
”Variable increment key,
“
▲
”Variable reduced key,
“”Screen Power Switch button。
“LED” Power indicator(Red means no have signal, Green means have signal)
2. Features and Major Technical Indicator
2.1 Structure Features
The part of screen Lift is adopt bilateral synchronous belt wheel with linear
optical axis transmission and low noise and stable structure. Angle tilt can
come true fixed tilt 15 degrees. Screen frame is adopt pure aluminum
with tempered glass front and rear, high-end atmosphere. And product
is adopt desktop embedded

design, can achieve seamless hidden with desktop.
2.2 :Major Technical Indicator
2.2.1. LIFT Technical Data(Sheet 1)
No. Name Date
1 Working Voltage frequency AC220-240V 50/60Hz
2 Consumed power <50W
3 single-working time 12S
4 Elevation angle 15°
5 Product weight 15Kg
2.2.2 Screen Technical Data(Sheet 2)
No. Name Date
1 Signal Type EDP
2 Display Size 17.3
3 Resolution 1920*1080
4 Aspect Ratio 16:9
5 Contrast 1000:1
6 Brightness 250
7 Viewing angle 80/80/80/80
8 Video signal mode VGA/HDMI
(Automatic Identification)

3.1 User out cut drawing size:
FIG 7 out cut size
3.2 Product structure drawing size:
Product structure drawing size
3. Structural dimensions and installation instructions:

3.2 Installation Notes:
3.2.1 Before operation, please remove two "transport fixing screws" on the
cover and clean the inside of the clamshell door foam filler.
3.2.2 The lifter embedded inside the opening, panel flush with the desktop.
3.2.3 Video Signal connector Cable(VGA or HDMI or DVI)
3.2.4 Connect the touch USB Cable(not need to connect the touch USB
cable if without touch function)
3.2.5 If need Central-controlled system, please connect the control line
RS485.
3.2.6 Connected the antenna with antenna base together
4. Turn on AC220V power supply,panel indicator islight, press UPkey to
complete the automatic elevation, the screen lights up and angle tilt
becomes fixed 15 degrees.
5. Technical date:
5.1 HEX system controlling code(Sheet 4)
All up FF AC E1 FF 00 00 DD 01 DC
All stop FF AC E1 FF 00 00 CD 01 CC
All down FF AC E1 FF 00 00 ED 01 EC
5.2 Computer software control
5.2.1 Download "Multifunctional lifting equipment Control Center" control
software from the company's official website.

5.2.2 Prepare a RS232-485 or USB-RS485 protocol converter.
5.2.3 Uses Windows XP systems to install the software.
5.2.4 Connect the LIFT equipment.
5.2.5 According to the software that comes with help files, you can use to
operate.
6. Solutions of monitor common problems:
Common failure analysis(Sheet 5)
No. Fault phenomenon Analysis reason
5.1 Display is blank ·Power switch is turned off?
·Signal source is interrupted?
5.2 Blurred characters · Is match with the resolution of the
computer?
Contrast and brightness adjustments
are correct?
5.3 Black Screen
·No signal may be turned off
automatically Brightness?
Brightness adjustment if adjust to the
minimum?
·Long press "Auto" key may cause
shutdown, the LED turns red.
7. Solutions of Lifter common problems:
7.1 All machine no power, light does not shine:
Pry the Insurance cover of power to check the fuse if damage? If so,
please change specifications 3.15A fuse.

FIG 10 Location of fuse socket GB
7.2 The control circuit board Common trouble diagnosis method:
7.2.1 Pls check the power supply socket "L" and "N" (between the circuit
board of the LT3 terminal) resistance is about 1.1K or so, which is
normal, if deviate from this range ,it has the problem.
7.2.2 Indicator light does not shine, the key is invalid, but computer control
normal: may be key board cable transport from strong vibration caused
by poor contact.
7.2.3 Circuit boards 12V abnormal, check L7812 if it's damage.
7.2.4 Circuit boards 5V abnormal, check L7805 if it's damage.
7.2.5 Up limit switch belong pulse level control, after the pulse remains
stopped. But the display power required to maintain the state of shading
for photoelectric control.
7.2.6 Down limit switch belong to low pause control, continued to decline at a
high level. Therefore, photoelectric control gobo stop during descent
should remain light shielding state.