Winix ZERO 4 User manual

WINIX ZERO 4 AIR PURIFIER
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
USER MANUAL

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 2
CONTENTS.............................................................................................................2
4-STAGE AIR PURIFICATION ................................................................................3
CONTROLS.............................................................................................................4
WHERE TO USE.....................................................................................................5
INSTALLING FILTERS ............................................................................................6
SAFETY AND CAUTIONS.......................................................................................8
INITIAL OPERATION...............................................................................................9
AUTO & SLEEP.....................................................................................................10
MANUAL & TIMER ................................................................................................11
PLASMAWAVE®& AIR QUALITY INDICATOR .....................................................12
FILTER CARE .......................................................................................................13
PARTICLE SENSOR CARE ..................................................................................17
CLEANING CARE .................................................................................................18
FREQUENTLY ASKED QUESTIONS ...................................................................19
SAFETY INSTRUCTIONS.....................................................................................20
PRODUCT WARRANTY .......................................................................................21
CONTENTS

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 3
Light sensor
PlasmaWave
Control Panel / Display Panel
Particle sensor
Power cord with plug
(This product is suitable
for 220-240V only.) Front panel
1
2
3
4
User ManualUnit
True HEPA
4-STAGE AIR PURIFICATION

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 4
Air Outlet Vent
Reset Button
press the RESET button
for at least 5 seconds.
Fan Speed Indicator
Indicates the
current fan speed.
Timer Indicator
If timer has been set, the
LED light indicates the set
time of operation.
Air Quality Indicator
Color-coded LED indicates one of
three levels of air quality.
Mode Button
Press to cycle through and set
the desired mode of operation
(Auto, Sleep).
Fan Speed Button
Enables Manual operation of the
unit. Press to cycle through and
set the desired fan speed (Low,
Medium, High, Turbo).
Light Sensor
Detects the
amount of
ambient light
within the
environment,
to adjust the
brightness
of the LED
indicators.
Timer Button
Press to cycle
through and set
desired length of
operation (1hr,
4hr, 8hr,[NO
TIMER])
Change Filter Indicator
LED light indicates when it is
PlasmaWave Indicator
Indicates whether
PlasmaWave is enabled or
disabled.
PlasmaWave Button
Enables or disables
PlasmaWave .
Power Button
Turns the unit on
CONTROLS

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 5
Allow 30 - 45cm of space between TVs, radios, and other electronic products electromagnetic interference from
certain electronics may cause product malfunction.
Place indoors away from direct sun light direct exposure may cause product malfunction or failure.
Only place on hard, at surfaces imsy or slanted surfaces may result in abnormal noise and vibrations.
30~45 cm 10 cm
Follow these instructions to reduce the risk of serious injury or death and
to reduce risk of damaging the unit.
Do not use around mist or fumes from
industrial oil or around large quantities of
metallic dust.
Do not place around heating elements.
Do not install in any sort of motor or
transport vehicle (trucks, boats, ships,
etc.).
Do not place in an area with excessive
amounts of noxious gases.
Do not place near any ammable materials
(aerosols, fuel, gases etc.).
Do not have unit facing into wind or draft.
Do not place below any electrical outlet. Do not place in excessively humid areas
where unit may become wet.
WHERE TO USE

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 6
This product comes with all required lters. The protective plastic wrap must be removed from the lter before use.
• Operating the unit without removing the plastic wrap may result in product failure.
• Unplug and make sure the unit is turned o before installing lter.
1. Remove the front panel by grasping its upper
edge and gently pulling forward.
2. Remove the lters from the unit, they are protect-
ed inside a plastic wrap
3. Remove lters from protective plastic wrap.
• Operating the unit without removing lters from
plastic wrap may cause abnormal noise, deforma-
tion, or re as a result of overheating.
NOTE : Refer to pages 13 - 15 for details on how to replace lters.
INSTALLING FILTERS

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 7
4. Install the lters until they t securely in place.
Filters must be installed in this order:
3 True HEPA Filter (rear)
2 Deodorization lter (middle)
1 Pre-lter (front)
• To install the Pre-lter, insert bottom tabs into the
slots on either side of the lower part of the unit,
then rotate upward to insert the upper tabs into
the slots at the top part of the unit until sides audi-
bly click into place.
5. Replace the front panel by rst inserting the latch
at the bottom edge into the base of the unit, then
rotate the panel upward toward the top of the unit
until the magnets pull the lid closed.
6. When to service and replace lter:
Filter Indicator Light When to service When to replace
1 Pre-lter none Clean once every 14 days Permanent
2 Deodorization lter
Can NOT be WASHED Lasts up to 12 months
3 True HEPA lter
• Intervals between lter replacement may vary depending on environment.
• For optimal use, Pre-lter can be cleaned once every 14 days which can extend the life of other lters.

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 8
Before operating this equipment, carefully read and follow these safety cautions
Ensure lters are inserted before running unit
running unit without lters can shorten the units life and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit
objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands
the high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked
blockage may lead to increased internal termperatures causing product failure and derformation.
Do not use the unit as a step stool or place heavy objects on it
personal injury may occur or product failure and deformation.
Follow these instructions to reduce the risk of serious injury or death and
to reduce risk of damaging the unit.
Do not pull on the power cord when
unplugging the unit
Do not tie or knot power cord when unit is
in operation
If the unit becomes submerged in water,
unplug it and contact customer service
Do not unplug or move the unit while in
operation
Do not plug additional appliances into the
same outlet or power supply
Do not touch the plug with wet hands
Unplug unit when not in operation for
extended periods of time
Cord can become damaged by forcefully
bending, pulling, twisting, bundling,
pinching or placing heavy objects on it
• If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufac-
turer or its service agent.
• This appliance is not intended for use by a person (including children) with reduced physical sensory or men-
tal capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
SAFETY AND CAUTIONS

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 9
1. Insert the power cord into an electrical outlet.
2. Press the ‘Power’ button.
NOTE : During the rst 30 seconds of power up, the Air Quality Indicator will cycle through Blue, Amber and Red
colors. The Particle Sensors take approximately 30 seconds to gauge the air quality in the environment, after
which normal operation will begin.
3. By default, when the unit rst powers on, the mode
will be set to Auto with PlasmaWave®enabled.
• When in Auto mode, the fan speed will be auto-
matically adjusted according to the environments
air quality.
• PlasmaWave® works to remove harmful airborne
contaminants.
NOTE :
• In Auto mode, as the indoor air quality improves, the fan speed will automatically be reduced to Low.
• When the unit is running, you may hear a chirping or buzzing sound. The sound is from large particles pass-
ing through PlasmaWave®, it is normal and does not signify product failure. To disable PlasmaWave®, see
page 12.
INITIAL OPERATION

USER MANUAL WINIX ZERO 4 AIR PURIFIER
Page 10
Auto Mode
Enables auto operation based on the unit’s air quality Particle Sensor.
1. Press the Mode button to select Auto mode.
• The LED ‘Auto’ light will indicate when Auto mode
is activated, and operation will begin.
NOTE : When in Auto mode the fan speed is automatically adjusted according to the indoor air quality. As the
indoor air quality improves, the fan speed will automatically be reduced. If the indoor air quality decreases, the
fan speed will automatically increase.
Sleep Mode
1. Press the Mode button to select Sleep mode.
• The LED ‘Sleep’ light will indicate when Sleep
mode is activated, and operation will begin.
NOTE :
• When Sleep mode is selected, the fan speed is automatically set to Low. The fan speed can be manually
changed by pressing the Fan Speed button, changing the unit into manual mode.
• When Sleep Mode is activated, the Air Quality Indicator LED light is disabled.
AUTO & SLEEP
Table of contents
Other Winix Air Cleaner manuals

Winix
Winix ZERO+ AUS-1250AZPU User manual

Winix
Winix 2020EU User manual

Winix
Winix 9500 User manual

Winix
Winix AW107 User manual

Winix
Winix HR1000 User manual

Winix
Winix 5300-2 User manual

Winix
Winix Zero S User manual

Winix
Winix C545 User manual

Winix
Winix AGN335 Series User manual

Winix
Winix ZERO+ User manual

Winix
Winix AUS-0850AAPU User manual

Winix
Winix ZERO 5 User manual

Winix
Winix FreshHome PlasmaWave WACP150 User manual

Winix
Winix AAPU500-JLE User manual

Winix
Winix ZERO Pro User manual

Winix
Winix QS User manual

Winix
Winix AZNU230-HWE User manual

Winix
Winix HR900 User manual

Winix
Winix NK100 User manual

Winix
Winix C535 User manual