WIKA IS-3 User manual

Operating instructions
操作说明书
EN
CN
Pressure transmitters model IS-3
IS-3 型压力变送器
IS-3 型压力变送器
Pressure transmitter model IS-3

2WIKA 操作说明书,IS-3 型压力变送器
EN
CN
MM/YYYY 国家代码基于 14095850.02 12/2014 EN/CN
IS-3 型操作说明书 页码 53 - 103
© 2014 WIKA Alexander Wiegand SE & Co. KG
All rights reserved./保留所有权利。
WIKA®is a registered trademark in various countries.
WIKA®是在各个国家/地区的注册商标。
Prior to starting any work, read the operating instructions!
Keep for later use!
在开始任何工作之前,请阅读本操作说明书!
请妥善保存,以备将来使用!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Operating instructions model IS-3 Page 3 - 52
更多语言请见 www.wika.com

3WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
Contents
Contents
Declarations of conformity can be found online at www.wika.com.
1. General information 4
2. Safety 6
3. Specications 12
4. Design and function 31
5. Transport, packaging and storage 31
6. Commissioning, operation 33
7. Adjusting the zero point and span 44
8. Maintenance and cleaning 47
9. Faults 48
10. Dismounting, return and disposal 50
Appendix: Declaration of conformity 102

4WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
1. General information
■
The pressure transmitter described in the operating instructions has been designed and manufactured using state-
of-the-art technology. All components are subject to stringent quality and environmental criteria during production.
Our management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument.Working safely requires that
all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range
of use.
■
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and
readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
■
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended
use, non-compliance with these operating instructions, assignment of insuciently qualied skilled personnel or
unauthorised modications to the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 81.58
- Application consultant: Tel.: +49 9372 132-8976
Fax: +49 9372 132-8008976
1. General information

5WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
WARNING!
... indicates a potentially dangerous situation in the hazardous area that can result in serious injury or
death, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces or liquids,
if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to equipment or
the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and trouble -free operation.
1. General information

6WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
2. Safety
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate instrument has been
selected in terms of measuring range, design and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
Danger of injury and damage to property due to escaping media
Escaping media can lead to serious injury. In the event of failure, components can be ejected or media
exhausted under high pressure.
■
Open the connections only after the system has been depressurised.
■
For pressures from 1,000 bar, employ a protective device to prevent parts from being ejected. The
protective device must not be removable without the use of tools.
■
Always operate the pressure measuring instrument within the overpressure limit, see chapter
3 “Specications”.
■
Ensure that the pressure in the system as a whole does not exceed the lowest maximum pressure of
any of its components. If varying or dierent pressures are to be expected in the system, components
must be used that can withstand the maximum expected pressure spikes.
■
Observe the working conditions in accordance with chapter 3 “Specications”.
■
Actions or alterations to the pressure transmitter, which are not described in these operating
instructions, are not permitted.
Further important safety instructions can be found in the individual chapters of these operating
instructions.
2.1 Intended use
The pressure transmitter is an intrinsically-safe supplied pressure measuring instrument and is used for the continuous
monitoring of gaseous media or liquids in potentially explosive areas which require category 1, 1/2 and 2 equipment.
ATEX and IECEx approval:
Pressure measuring instrument approved for use in hazardous areas.

7WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
Approval ratings ATEX and IECEx:
Gases and mist: Mounting to zone 0 (EPL Ga/Gb); installation in zone 0 (EPL Ga) and zone 2 (EPL Gc)
Dusts: Mounting to zone 20 (EPL Da/Db); installation in zone 20 (EPL Da) and zone 22 (EPL Dc)
Mining: EPL Ma
The instrument has been designed and built solely for the intended use described here, and may only be used
accordingly.
The technical specications contained in these operating instructions must be observed. Improper handling or
operation of the instrument outside of its technical specications requires the instrument to be taken out of service
immediately and inspected by an authorised WIKA service engineer.
2.2 Personnelqualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to equipment.
■
The activities described in these operating instructions may only be carried out by skilled personnel
who have the qualications described below.
■
Keep unqualied personnel away from hazardous areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement
and control technology and on their experience and knowledge of country-specic regulations, current standards and
directives, are capable of carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2. Safety

8WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
2.3 Special hazards
For ignition protection Ex nA and Ex tc: The thermal tests according to IEC 60079-0:2011 26.5.1 were conducted for
the operation in the nominal pressure range.
WARNING!
Observe the information given in the applicable type examination certicate and the relevant country-
specic regulations for installation and use in hazardous areas (e.g. IEC 60079-14, NEC, CEC).
Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
Physical injury and damage to property caused by hair-line cracks
The service life of the pressure transmitter is limited by a maximum number of load cycles.The
maximum number depends on the pressure prole of the application (extent of change in pressure, time
of pressure rise and pressure drop, ...). Once the maximum number of load cycles has been exceeded,
it can lead to leaks through hair-line cracks, which can cause physical injury and damage to property.
■
Request the maximum number of load cycles from the manufacturer.
■
Replace the pressure transmitter once it has exceeded the maximum number of load cycles.
■
Take safety measures to eliminate hazards due to hair-line cracks.
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids, and refrigeration
plants, compressors, etc., in addition to all standard regulations, the appropriate existing codes or
regulations must also be followed.
WARNING!
Residual media in the dismounted instrument can result in a risk to persons, the environment and equip-
ment. Take sucient precautionary measures.
Do not use this instrument in safety or emergency stop devices. Incorrect use of the instrument can
result in injury.
Should a failure occur, aggressive media with extremely high temperature and under high pressure or
vacuum may be present at the instrument.
Further important safety instructions can be found in the individual chapters of these operating instruc-
tions.
2. Safety

9WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
2.4 Labelling, safety marks
Product label
Explanation of symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
ATEX European Explosion Protection Directive
(Atmosphère = AT, explosible = EX)
Instruments bearing this mark comply with the requirements of the European directive 94/9/EC (ATEX)
on explosion protection.
2. Safety
Safety-related maximum
values (for ignition protec-
tion Ex i)
Pin assignment
0158
IS 3
-30 inHg ... 300 psi
DC 10 ... 30 V
4 ... 20 mA
00639080
11639110
P#
S#
BVS 14 ATEX E 035 X
IECEx BVS 14.0030 X
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
II 1/2 D Ex ia III C T135 °C Da/Db
I M1 Ex ia I Ma
gy
U+ bn
U- gn
Ui/Vmax = 30V
Ii/Imax = 100 mA
Pi = 800 mW
Ci ≤16,5 nF
Li = 0 µH
T6 at 60 °C
T5 at 75 °C
T4 at 105 °C
For dust see manual!
Shield not connected to the case
Code IS - 3 - X - XXXX- XXX - XXXXXXX - XXXXXXX - XXXX
WIKA Alexander Wiegand SE & Co.KG, 63911 Klingenberg Made in Germany 2F
Model designation
Measuring range
Output signal
Power supply
P# Product no.
S# Serial no.
Type code
Ignition protection type

10 WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
2.5 Type code
IS-3-A-BCDE-***-*******-*QRST**-W***
* = not relevant for instruments in Ex-version
Position Description Feature
A process connection type 0 = pressure channel
1 = front ush
BC area of use 11 = EPL Ga (ATEX: II 1G)
12 = EPL Ga (ATEX: II 1G) + EPL Ma (ATEX: I M1)
13 = EPL Ga (ATEX: II 1G) + EPL Da (ATEX: II 1D)
14 = EPL Ga (ATEX: II 1G) + EPL Da (ATEX: II 1D) + EPL Ma (ATEX: I M1)
21 = EPL Ga/Gb (ATEX: II 1/2G)
22 = EPL Ga/Gb (ATEX: II 1/2G) + EPL Ma (ATEX: I M1)
23 = EPL Ga/Gb (ATEX: II 1/2G) + EPL Da/Db (ATEX: II 1/2D)
24 = EPL Ga/Gb (ATEX: II 1/2G) + EPL Da/Db (ATEX: II 1/2D) + EPL Ma (ATEX: I M1)
31 = EPL Gc (ATEX: II 3G)
33 = EPL Gc (ATEX: II 3G) + EPL Dc (ATEX: II 3D)
D approvals 1 or 3 = ATEX + IECEx
4 = IECEx + ATEX zone 2 / 22
E ignition protection type 1 = intrinsically safe
2 = non sparking nA
3 = non sparking nA + dust ignition protection by enclosure tc
Qadjustability Z = without
T = zero point / span adjustable
2. Safety
Other manuals for IS-3
2
Table of contents
Other WIKA Transmitter manuals
Popular Transmitter manuals by other brands

Dejero
Dejero EnGo 3x manual

Rosemount
Rosemount 4600 Reference manual

Speaka Professional
Speaka Professional 2342740 operating instructions

trubomat
trubomat GAB 1000 instruction manual

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 instructions

Rondish
Rondish UT-11 quick start guide