WIKA UPT-20 User manual

Operating instructions
Betriebsanleitung
GB
D
Prozesstransmitter, Typ UPT-2x
Process transmitter, model UPT-20
Process transmitter, model UPT-2x

2
14068347.01 06/2014 GB/D
WIKA operating instructions process transmitter, model UPT-2x
GB
D
© 2014 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Operating instructions model UPT-2x Page 3 - 62
Betriebsanleitung Typ UPT-2x Seite 63 - 122

3
WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
Contents
Contents
1. General information 8
2. Safety 9
3. Specications 12
4. Design and function 20
5. Transport, packaging and storage 22
6. Commissioning, operation 23
7. Display and operating unit, model DI-PT-U 27
7.1 Design and description 27
7.2 Accessing/exiting the operating menu 27
7.3 Installation/Removal 28
7.4 Setting the main display 29
7.5 Setting the additional display 30
8. Congurationwithoutdisplayandoperatingunit 31
8.1 Performing a mounting correction (oset) 31
8.2 Conguring over HARTinterface 32
9. Congurationviadisplayandoperatingunit 33
9.1 Conguring the measuring task 33
9.1.1 Conguring pressure measurement 33
9.1.2 Conguring level measurement 34
9.2 Setting the units 35
9.2.1 Setting the pressure unit 35
9.2.2 Set length unit (for level measurement) 35
9.2.3 Setting the density unit 36

4WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
Contents
9.2.4 Setting the temperature unit 36
9.3 Scaling the measuring range 37
9.3.1 Performing a wet adjustment 37
9.3.2 Performing a dry adjustment 38
9.4 Setting the mode 39
9.5 Mounting correction (oset) 40
9.5.1 Performing a wet adjustment 40
9.5.2 Performing a dry adjustment 40
9.6 Setting the damping 41
9.7 Write protection 42
9.7.1 Activating/deactivating the write protection 42
9.7.2 Changing PIN 42
10. Diagnostic functions 43
10.1 Simulations 43
10.1.1 Performing a pressure simulation 43
10.1.2 Performing a current simulation 43
10.2 Indicating/ressetting drag pointer 44
10.2.1 Drag pointer Pmin / Pmax 44
10.2.2 Drag pointer PVmin / PVmax 45
10.2.3 Drag pointer Tmin / Tmax 45
10.3 Indicating/resetting operating time 45
11. Detail setup 46
11.1 Setting the language 46
11.2 Marking the measuring point (TAG) 46
11.2.1 Setting the TAG short 46

5
WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
Contents
11.2.2 Setting the TAG long 46
11.3 Setting the alarm signal 47
11.4 Setting the signal limits 47
11.5 Setting the contrast of the LC display 48
11.6 Restoring factory setting 48
11.7 Setting the HARTcommunication 49
11.7.1 Setting the short address (multidrop mode) 49
11.7.2 Activating/deactivating constant current 49
12. Instrument information 50
12.1 Indicating measuring range 50
12.2 Indicating date of manufacture 50
12.3 Indicating rmware version 50
12.4 Indicating serial number 51
13. Maintenance and cleaning 51
14. Faults 52
15. Dismounting, return and disposal 53
16. Accessories 54
Appendix 2: Menu tree, basic setting 56
Appendix 3: Menu tree, display 58
Appendix 4: Menu tree, diagnostic 59
Appendix 5: Menu tree, detail setup 60
Appendix 6: Menu tree, info 62
Declartations of conformity can be found online at www.wika.com

6WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
1. General information
1. General information
■
The process transmitter described in the operating instructions has been designed
and manufactured using state-of-the-art technology. All components are subject
to stringent quality and environmental criteria during production. Our management
systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instru-
ment. Working safely requires that all safety instructions and work instructions are
observed.
■
Observe the relevant local accident prevention regulations and general safety regula-
tions for the instrument's range of use.
■
The operating instructions are part of the product and must be kept in the immediate
vicinity of the instrument and readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instructions
prior to beginning any work.
■
The manufacturer's liability is void in the case of any damage caused by using the
product contrary to its intended use, non-compliance with these operating instruc-
tions, assignment of insuciently qualied skilled personnel or unauthorised modi-
cations to the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 86.05
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.com
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury
or death, if not avoided.

7
WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
1. General information / 2. Safety
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries
or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and
trouble-free operation.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appro-
priate instrument has been selected in terms of measuring range, design
and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equip-
ment.
Further important safety instructions can be found in the individual
chapters of these operating instructions.
2.1 Intended use
The process transmitter measures gauge pressure, absolute pressure and vacuum. The
physical quantity pressure is converted into an electrical signal.
The process transmitter has been designed exclusively for industrial applications in
internal and external locations. Its scope of application is dened by its technical perfor-
mance limits and its materials. Improper use is dened as any application that exceeds
the technical performance limits or is not compatible with the materials. Checking
against improper use is the responsibility of the operator.
The instrument has been designed and built solely for the intended use described here,
and may only be used accordingly.
The technical specications contained in these operating instructions must be
observed. Improper handling or operation of the instrument outside of its technical
specications requires the instrument to be taken out of service immediately and
inspected by an authorised WIKA service engineer.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use.

8WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
2. Safety
2.2 Personnelqualication
WARNING!
Riskofinjuryshouldqualicationbeinsucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried
out by skilled personnel who have the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowl-
edge of country-specic regulations, current standards and directives, are capable of
carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive
media, compatibility of materials.
2.3 Personalprotectiveequipment
The personal protective equipment is designed to protect the skilled personnel from
hazards that could impair their safety or health during work. When carrying out dierent
work on and with the instrument, personal protective equipment must be worn.
Followtheinstructionsdisplayedintheworkarearegardingpersonalprotective
equipment!
The requisite personal protective equipment must be provided by the operating
company.
2.4 Specialhazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases
or liquids, and refrigeration plants, compressors, etc., in addition to all
standard regulations, the appropriate existing codes or regulations must also
be followed.
WARNING!
Residual media in the dismounted process transmitter can result in a risk to
personnel, the environment and equipment.
Take sucient precautionary measures.

9
WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
2. Safety
2.5 Labelling, safety marks
Product label
Pin assignment Model code
Power supply S# Serial no.
Output signal P# Product no.
Measuring range Date of manufactureYYYY-MM
Explanation of symbols
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
Output signal
Powersupply
Ground (GND)

10 WIKA operating instructions process transmitter, model UPT-2x
14068347.01 06/2014 GB/D
GB
3.Specications
3. Specications
3.1 Measuring range (see product label)
Gauge pressure
bar 0 ... 0.4 0 ... 1.6 0 ... 6 0 ... 16 0 ... 40
0 ... 100 0 ... 250 0 ... 600 0 ... 1,000
psi 0 ... 10 0 ... 15 0 ... 30 0 ... 100 0 ... 300
0 ... 500 0 ... 1,500 0 ... 5,000 0 ... 10,000
Absolute pressure
bar 0 ... 0.4 0 ... 1.6 0 ... 6 0 ... 16 0 ... 40
psi 0 ... 30 0 ... 100 0 ... 300 0 ... 500
Vacuum and +/- measuring ranges
bar -0.4 ... 0 -0.2 ... +0.2 -1 ... +0.6 -1 ... +5 -1 ... +15
-1 ... +40
psi -14.5 ... 0 -14.5 ... +15 -14.5 ... +100 -14.5 ... +300 -14.5 ... +600
Vacuumtightness
Vacuum resistance is provided, except for instruments for oxygen applications.
Overpressurelimit
Measuring range Overpressurelimit
≤ 16 bar/300 psi 3 times
> 16 bar/300 psi 2 times
Other manuals for UPT-20
2
Table of contents
Languages:
Other WIKA Transmitter manuals
Popular Transmitter manuals by other brands

Dejero
Dejero EnGo 3x manual

Rosemount
Rosemount 4600 Reference manual

Speaka Professional
Speaka Professional 2342740 operating instructions

trubomat
trubomat GAB 1000 instruction manual

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 instructions

Rondish
Rondish UT-11 quick start guide