VOKERA RC05 User manual

Users
Instructions
THESE INSTRUCTIONS
TO BE RETAINED
BY USER
RC05 Programmable
room thermostat

2

3
CONTENTS
General Information 4
Description of Control Panel 6
Description of Buttons 6
Description of Display 7
Using the Control Panel 8
Regulating and Testing the System 8
Room Thermostat 10
Timer thermostat 12
Boiler Control 15
Available Functions 18
Regulating the Room Thermostat Temperature 18
Regulating the Domestic Hot Water Temperature 19
Regulating the Heating and Domestic Hot Water Temperature 20
Weekly Timer Thermostat Function 23
Temporary change in level 26
Cleaning Function 27
Holiday Function 28
Combustion Analysis 29
Fault Signalling 30

4
GENERAL INFORMATION
TO ENSURETHATTHEREMOTECONTROLPANELIS USED CORRECTLY, PLEASE
READ CAREFULLY THE ENTIRE CONTENTS OF THIS MANUAL.
WARNINGS
1) The remote control panel should be
installed in the room that is most easily
accessibleforcheckingthetemperature
of the environment (normally the
lounge).
2) To ensure correct operation of the
sensor, the control panel should be
positioned at a height of 1.5 metres
from the floor.
3) The control panel is supplied with low
voltage directly by the boiler. It also
contains a buffer battery, which has a
minimumlifeof 4yearsand guarantees
that the user settings are maintained
even when there is a black-out or a
break in the boiler connection.
4) It is essential that the control panel be
kept well away from heat sources and
draughts: as these may affect the
accuracy of the room thermostat
incorporated in the panel.
5) Do not attempt to open or remove the
panel, it requires no maintenance.
6) Do not press against the surface of the
liquidcrystal display:thiscoulddamage
the surface itself and cause viewing
problems.
7) To clean the display, simply wipe with a
dry cloth: any infiltrating liquid could
damage the liquid crystals.
WHAT IS THE REMOTE CONTROL
PANEL USED FOR?
The control panel offers the possibility of
controlling the operation of your boiler
without having to access it directly.
The control panel is normally installed in
the largest room of the house where it will
always be easy to make checks and
regulations.
HOW IT IS USED
The control panel has three operating
modes:
1) ROOM THERMOSTAT
Thecontrolpanelkeepsthetemperature
of the room constant on the basis of the
settings made by the user.
2) PROGRAMMABLE ROOM
THERMOSTAT
In this mode, you can programme 2
different temperatures settings for
certain periods of the day.

5
3) BOILER CONTROL
Inthismodethecontrol panel operates the
boilercontrols only.Itdoes notcontrol room
temperature or ON/OFF periods.
EXPLANATION OF TECHNICALTERMS
•Heating water: the water that flows
throughtheradiatorshavingbeenheated
in the boiler.
•Domestic hot water: thewaterthatflows
through the DHW fittings.
•Error code: a code that appears on the
display and signals any faults in the
boiler.
•Initial configuration: the configuration
set on the control panel when it is
switchedon for the first time or when it is
reset.
•Display: the liquid crystal screen on
which all the symbols corresponding to
the various functions are displayed.
•Antifreeze function: the function that
prevents a drop in temperature freezing
thewaterthatflowsin the pipes, causing
damage to the heating system. This
function is activated when the
environmental temperature drops below
6.6 °C.
•Reset: the operation that restores the
initial configuration of the control panel,
clearing all settings made by the user,
except for the system time.
•Summer operating mode: the mode in
whichthecontrolpanelistobesetwhen
the heating system does not have to be
in operation (e.g. spring, summer).
Theboilersuppliesdomestichotwateronly.
•Winter operating mode: the status in
whichthecontrolpanelistobesetwhen
theheating systemhastobe inoperation
(e.g. autumn, winter).
The boiler can supplies heating and
domestic hot water.
•Comfort level temperature: the
temperaturethatrepresentsidealheating
for the rooms.
•Room temperature: the temperature
measuredintheroomin which the panel
is installed.
•Outdoor temperature: the temperature
measured by the external sensor.
•Climatic curve (Linea & Compact
only): this is the relation between the
outdoor temperature and the calculate
flow outlet temperature, required when
an external sensor is fitted. The RC05
checks the temperature sensed at the
external sensor and calculates the
required flow outlet temperature based
on the curve that has been set on the
RC05 (see installation instructions). The
calculated flow outlet temperature
ensures optimum comfort and efficiency
is maintened. The curve is set by your
installer during the installation of the
RC05.
•Economy level temperature: the
temperature setting used during night-
setback or to maintain a minimum
temperature level in the property.
NOTE
• Theroom temperatureisdisplayedin the
range from -9.9 °C to 38 °C.
• The outdoor temperature is displayed in
the range from -20 °C to 18 °C.
• Temperatures outside these ranges are
indicated by means of three dashes “-
- -”.

6
Regulates the heating and domestic hot water temperature
Makes a temporary change in level
Programs the boiler
Changes mode (OFF-SUMMER-WINTER)
Sets cleaning and holiday function
Increases setting
Selects and confirms data and changes room temperature
Decreases setting
Releases boiler, reset data and tests display
NOTE: thesymbolsofthebuttonsshownintheillustrationandkeyareusedthroughout
the text of this manual.
DESCRIPTION OF CONTROL PANEL
DESCRIPTION OF BUTTONS

7
DESCRIPTION OF DISPLAY
15 16
17 18
5
4
3
21
6
78
9
10
11
12
13
14
1 -Boiler lockout indicator
2 -Heat request indicator
3 -Heating indicator
4 -Domestic hot water indicator
5 -Economy level temperature
indicator
6 -Comfort level temperature
indicator
7 -Scheduled servicing indicator
8 -Room thermostat indicator
9 -Timer thermostat indicator
10 -Boiler control indicator
11 -Underfloor heating function
indicator
12 -Thermoregulation status
indicator
13 -Cleaning/holiday function
indicator
14 -Telephone interface function
indicator
15 - Time and error numeric display field
16 - Temperature numeric display field
17 - Daily schedule progress bar
18 - Week day display segments
19 - EXT, outdoor temperature
NOTE: the symbols of the indicators shown in the key are used throughout the text of
this manual.
19

8
Fig. 3
USING THE CONTROL PANEL
SETTING AND TESTING THE RC05
It will be necessary to set or program the RC05 when it is first connected to the boiler. It
may be also necessary to set the time and/or program if the unit is reset or the battery
has been changed. If no selections are made within10 seconds, during regulation and
testing, the system exits automatically from the procedure.
Fig. 1
OFF POSITION
When the boiler has an electrical supply
and is connected to the RC05, the unit will
be in the OFF position.
SETTING THE TIME
When the display shows the word OFF:
1) Press the button
2) On the display :
• the two time digits start to blink
3) To set the hour, press the and
buttons
4) Press to confirm
Fig. 2 Fig. 4
5) On the display:
• the two minute digits start to blink
6) To set the minutes, press the and
buttons
7) Press to confirm.
8) On the display (fig. 4):
• the week day indicator dash starts to
blink
9) To set the day, press the and
buttons
10)Press toconfirm.Ifconfirmation
is not given within 10 seconds, the
system exits automatically from the
procedure.

9
Fig. 5
TESTING THE DISPLAY
When the display shows the word OFF:
1) Press and release the button
2) The display shows:
• all indicators for about 3 seconds
CHOOSE THE OPERATING MODE
The RC05 is supplied ready for use as a
ROOMTHERMOSTAT.To enableuseasa
programmableroomthermostat, see page
12. To enable use as a boiler only control,
see page 15.
Fig. 6
RESETTING THE SYSTEM
When the display shows the word OFF:
1) Keep the button pressed for 5
seconds
2) The display shows:
• all the indicators
3) 5 seconds after the system has been
reset, the display is cleared.
DEFAULT SETTING
Operating mode ROOMTHERMOSTAT
DHW level temperature 42.5°C
Central heating level temperature 71.5°C
Curve C5
Room thermostat level 20.0°C
Comfort level temperature 20°C
Economy level temperature 16°C
Reset does not change time setting. Standard program is set for the timer themostat (see page 12).

10
Fig. 8
Fig. 7
ROOM THERMOSTAT
If used as a room thermostat, the control
panel enables you to:
• set the desired room temperature
• control the room temperature
• regulate the temperature of the heating
and the domestic hot water.
There are three operating modes:
• ROOMTHERMOSTATOFF
• ROOMTHERMOSTATSUMMER
• ROOMTHERMOSTATWINTER
WARNING: in all operating modes, the
symbol is displayed.
When the button is pressed, the
boiler switches from one operating mode
to another (OFF-SUMMER-WINTER)
(fig. 7).
ROOM THERMOSTAT OFF
WARNING: when the system is turned on
for the first time or reset, it enters ROOM
THERMOSTAT OFF mode. In this
operating mode, the control panel is off.
The display:
• the word OFF in the temperature field
(fig. 8)
To switch off the panel (for short periods)
press button till the display shows
the word OFF.
When the button is pressed, the
system enters ROOM THERMOSTAT
SUMMER operating mode (fig.7).
Other manuals for RC05
1
Table of contents
Other VOKERA Thermostat manuals
Popular Thermostat manuals by other brands

Saswell
Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo
Aircalo TFP1-ET85P2 operating manual

Honeywell
Honeywell CM721 user manual

Carrier
Carrier DEBONAIR 33CS Installation and operating instructions

Lennox
Lennox iHarmony Zone Thermostat Installation and setup guide

Gemtech
Gemtech GT7000 Operation